09180-30050 OVER-HAUE KIT, TIM Denso Cross


 

Information over-haue kit, tim

09180-30050 OVER-HAUE KIT, TIM
Rating:
37
Buy OVER-HAUE KIT, TIM 09180-30050 genuine, new aftermarket engine parts with delivery

Components :

001. OVER-HAUE KIT, TIM 09180-30050

Scheme ###:

000. [01] 09180-30050 OVER-HAUE KIT, TIM
001. [1C] 90557-28000 RING, SHAFT SNAP
001. [1C] 90557-34008 RING, SHAFT SNAP
001. [1C] 90557-40000 RING, SHAFT SNAP
004. [1C] 94901-40210 WASHER, COUNTERSUN
004. [1C] 94901-50500 WASHER, SPRING

Include in #3:

09180-30050 as OVER-HAUE KIT, TIM

Cross reference number



Part num Firm num Firm Name
09180-30050    OVER-HAUE KIT, TIM

Use as kit:

0900002510 0918000400 Timer assy, automa 0918030050
0900003420 0918000310 Timer assy, automa 0918030050
0900003430 0918000310 Timer assy, automa 0918030050
0900003680 0918000310 Timer assy, automa 0918030050
0900003690 0918000310 Timer assy, automa 0918030050
0900003700 0918000310 Timer assy, automa 0918030050
0900003870 0918000310 Timer assy, automa 0918030050
0900006580 0918000400 Timer assy, automa 0918030050
0900006630 0918000510 Timer assy, automa 0918030050
0900007090 0918000510 Timer assy, automa 0918030050
0900007160 0918000510 Timer assy, automa 0918030050
0900007530 0918000510 Timer assy, automa 0918030050
0900007630 0918000400 Timer assy, automa 0918030050
0900007670 0918000400 Timer assy, automa 0918030050
0900007850 0918000400 Timer assy, automa 0918030050
0900008770 0918000400 Timer assy, automa 0918030050
0900008780 0918000400 Timer assy, automa 0918030050
0900008790 0918000400 Timer assy, automa 0918030050
0900009180 0918000510 Timer assy, automa 0918030050
0900009190 0918000510 Timer assy, automa 0918030050
0900009200 0918000510 Timer assy, automa 0918030050
0900009560 0918000400 Timer assy, automa 0918030050
0900009830 0918000400 Timer assy, automa 0918030050
0918000310 0918000310 Timer assy, automa 0918030050
0918000400 0918000400 Timer assy, automa 0918030050
0918000510 0918000510 Timer assy, automa 0918030050
0918000980 0918000980 Timer assy, automa 0918030050
0918001040 0918001040 Timer assy, automa 0918030050
0918001070 0918001070 Timer assy, automa 0918030050
0918001240 0918001240 Timer assy, automa 0918030050
0918001260 0918001260 Timer assy, automa 0918030050
0918001280 0918001280 Timer assy, automa 0918030050
0918001330 0918001330 Timer assy, automa 0918030050
0918001360 0918001360 Timer assy, automa 0918030050
0918001460 0918001460 Timer assy, automa 0918030050
0918001490 0918001490 Timer assy, automa 0918030050
0918001510 0918001510 Timer assy, automa 0918030050
0918001540 0918001540 Timer assy, automa 0918030050
0918001630 0918001630 Timer assy, automa 0918030050
0918001650 0918001650 Timer assy, automa 0918030050
0918001700 0918001700 Timer assy, automa 0918030050
0918001710 0918001710 Timer assy, automa 0918030050
0918001720 0918001720 Timer assy, automa 0918030050
0918001730 0918001730 Timer assy, automa 0918030050
0918001750 0918001750 Timer assy, automa 0918030050
0918001840 0918001840 Timer assy, automa 0918030050
0918001860 0918001860 Timer assy, automa 0918030050
0918001870 0918001870 Timer assy, automa 0918030050
0918001890 0918001890 Timer assy, automa 0918030050
0918001920 0918001920 Timer assy, automa 0918030050
0918001950 0918001950 Timer assy, automa 0918030050
0918001990 0918001990 Timer assy, automa 0918030050
0918002120 0918002120 Timer assy, automa 0918030050
0918002180 0918002180 Timer assy, automa 0918030050
0918002200 0918002200 Timer assy, automa 0918030050
0918002210 0918002210 Timer assy, automa 0918030050
0918002230 0918002230 Timer assy, automa 0918030050
0918002240 0918002240 Timer assy, automa 0918030050
0918002250 0918002250 Timer assy, automa 0918030050
0918002310 0918002310 Timer assy, automa 0918030050
0918002320 0918002320 Timer assy, automa 0918030050
0918002330 0918002330 Timer assy, automa 0918030050
0918002380 0918002380 Timer assy, automa 0918030050
0918002400 0918002400 Timer assy, automa 0918030050
0918002430 0918002430 Timer assy, automa 0918030050
0918002450 0918002450 Timer assy, automa 0918030050
0918002460 0918002460 Timer assy, automa 0918030050
0918002730 0918002730 Timer assy, automa 0918030050
0918002790 0918002790 Timer assy, automa 0918030050
0918002800 0918002800 Timer assy, automa 0918030050
0918002840 0918002840 Timer assy, automa 0918030050
0918002890 0918002890 Timer assy, automa 0918030050
0918002910 0918002910 Timer assy, automa 0918030050
0918002940 0918002940 Timer assy, automa 0918030050
0918002960 0918002960 Timer assy, automa 0918030050
0918003030 0918003030 Timer assy, automa 0918030050
0918003060 0918003060 Timer assy, automa 0918030050
0918003130 0918003130 Timer assy, automa 0918030050
0918003170 0918003170 Timer assy, automa 0918030050
0918003250 0918003250 Timer assy, automa 0918030050
0918003460 0918003460 Timer assy, automa 0918030050
0918003490 0918003490 Timer assy, automa 0918030050
0918003500 0918003500 Timer assy, automa 0918030050
0918003630 0918003630 Timer assy, automa 0918030050
0918003660 0918003660 Timer assy, automa 0918030050
0918003770 0918003770 Timer assy, automa 0918030050
0918003790 0918003790 Timer assy, automa 0918030050
0918003810 0918003810 Timer assy, automa 0918030050
0918003820 0918003820 Timer assy, automa 0918030050
0918003930 0918003930 Timer assy, automa 0918030050
0918004050 0918004050 Timer assy, automa 0918030050
0920001000 0918003130 Timer assy, automa 0918030050
0920001010 0918003130 Timer assy, automa 0918030050
0920002320 0918003790 Timer assy, automa 0918030050
0920002360 0918003790 Timer assy, automa 0918030050
0920003870 0918004050 Timer assy, automa 0918030050
0920003880 0918004050 Timer assy, automa 0918030050
0930000010 0918001330 Timer assy, automa 0918030050
0930000020 0918001330 Timer assy, automa 0918030050
0930000030 0918001330 Timer assy, automa 0918030050




Information:

Fuel Pump Reference Parts
1. Select a pump typically serviced in your dealer shop. Do NOT use electronic (PEEC) fuel pumps as reference parts. A 3306B pump is recommended for your reference pump.2. If necessary, disassemble and visually inspect pump cam, lifters, plunger and barrel, etc. to assure all internal components are in good condition.3. Check pump plunger and barrel bonnet nut torque. Torque nuts to recommended value according to the service manual.4. Back out the pump governor load stop(s) and idle setting screws.5. Obtain the required pump rack zero pin. It is recommended each reference pump have its own zero pin (order a spare from the parts department) and permanently attach to the reference pump.6. Install the reference pump on the test stand.7. Make sure the test stand has the latest master fuel nozzles. All master nozzles must have the same part number.8. Inspect each test stand high pressure fuel line inside diameter (ID) for "close-in" from repeated use.Repeated assembly of the high pressure fuel lines can cause the tubing's inside diameter to collapse or "close-in", resulting in low delivery volume. Testing fuel injection pumps using worn or partially closed high pressure fuel lines will cause inaccurate test results. All high pressure fuel lines used on the test stand should be checked every three months.
Always use a wrench to hold the hex fitting on top of the master nozzle, when assembling or disassembling lines. If a wrench is not used, the master nozzle and manifold it is installed into may be damaged.
Check fuel line for "Close-in" Do NOT use fuel lines with an ID (inside diameter) LESS than 1.191 mm (0.0469 in). The fuel line ID can be checked using a 1.2 mm (.047 in) drill.If the drill bit can NOT be inserted into the fuel line high pressure hole, either drill out the line using a 1.6 mm (.063 in) drill or replace the fuel line with a new line. Use the same length and internal diameter lines each time the reference pump is tested.
If the fuel lines are not completely and thoroughly cleaned out after the drilling procedure, metal particles or foreign debris in the line will damage the master nozzles and contaminate the calibration fluid in the test stand.
After the hole has been drilled to the correct size, clean the line with solvent and remove any metal particles. Blow compressed air through the lines, after cleaning, to remove any solvent.
When using pressure air, wear a protective face shield and protective clothing. The maximum air pressure at the nozzle must be less than 205 kPa (30 psi) for cleaning purposes.
9. Identify fuel lines and nozzles in the same order as the reference pump plunger and barrels (1-6 or 1-12) and use the same lines and nozzles each time the reference pump is run on the test bench.10. Select two test points (speeds and shot settings) that will cover the delivery range realized in a dealer's shop.Always set up the test points using only the pump rack

Have questions with 09180-30050?