105220-7500 ZEXEL 9 441 610 469 BOSCH SUPPLY PUMP 9441610469 1052207500 8973690000


 

Information supply pump

BOSCH 9 441 610 469 9441610469
ZEXEL 105220-7500 1052207500
ISUZU 8973690000 8973690000
105220-7500 SUPPLY PUMP
Rating:
17
Buy SUPPLY PUMP 105220-7500 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152062-0120 PUMP HOUSING
2. [1] 152030-0200 STOP PIN
5. [1] 152100-2301 PUMP PLUNGER
6. [1] 152102-0400 COMPRESSION SPRING
7. [1] 152105-1600 CAPSULE
8. [1] 139526-0000 GASKET
14. [2] 152115-0500 VALVE BODY
14. [2] 152115-0500 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
17. [1] 152118-0900 ADAPTOR
18. [2] 029631-6060 O-RING
18. [2] 029631-6060 O-RING
25. [1] 152200-6720 HAND PRIMER
30. [1] 152300-7720 EYE BOLT
32. [1] 152300-7720 EYE BOLT
35. [3] 029341-4080 GASKET
36. [3] 029341-4080 GASKET

Cross reference number

Zexel num
Bosch num
Firm num
Name
105220-7500 
9 441 610 469 
NP-FP/KSP-A 
8973690000  ISUZU
SUPPLY PUMP
A K 14GC FEED PUMP F/P




Information:

Introduction
The objective of this topic is to assist users in establishing a Preventive Maintenance Program for Standby Generator Sets or as an aid in evaluating their present programs.Standby Generator Sets may not be needed very often, but when they are, it is usually under emergency conditions. Maintenance of these standby units is very important. They must always be in excellent operating condition, ready to work under load at any time.Establishing a Preventive Maintenance Program will provide maximum availability of a standby generator set when needed, longer engine and generator life, and a minimum of expensive repairs.The recommended WEEKLY maintenance checks can be performed by an operator. The checks consist of basic maintenance requirements to ensure the standby generator set will be ready for immediate use should the need arise.All YEARLY and THREE YEAR maintenance should be performed by an authorized mechanic or your Caterpillar dealer. These checks and maintenance requirements will require that the standby generator be run under load conditions, and may require special test equipment.These guidelines are to be used with the information contained in the Operation and Maintenance sections of this manual. The Operation and Maintenance sections of the manual will provide the necessary information on how to perform the checks and routine maintenance.Refer to the Generator and Engine Service Manuals and Recommended Preventive Maintenance Schedules for Standby Generator Sets, SEBU6042 for additional information, or contact your Caterpillar dealer for assistance.Inspection and Maintenance Agreements
Your Caterpillar dealer can establish an Inspection and Preventive Maintenance Program for your generator set to provide maximum reliability, increased engine and generator life, and minimize expensive repairs. Contact your Caterpillar dealer for details.General Recommendations
Safety
The stop-manual-automatic switch on the cranking panel must be set at STOP position when performing maintenance or repair work on a standby generator set. This prevents the unit from starting if a power failure or voltage drop should occur while working on the unit.To prevent personal injury due to accidental starting of the engine, disconnect the batteries or disable the starting system before doing maintenance or repair work.Lock out all switch gear and automatic transfer switches associated with the generator while performing any generator maintenance or repairs. Make sure no shock hazard exists.Failure to comply could result in personal injury or death.
Always make repairs with the engine stopped and the starting system disabled. When servicing the generator, make sure that switch gear and automatic transfer switches will not present a shock hazard. Lock them out on the generator being serviced.Record Keeping
Maintain a log or record keeping system to document all gauge readings, problems, repairs, and maintenance performed on the equipment.Space Heaters
Moisture is a natural enemy of generators and all electrical equipment. Every effort must be made to keep the generator as dry as possible. Space heaters should be operated inside the generator when it is not in use to maintain the integrity of the generator windings.

Have questions with 105220-7500?





Group cross 105220-7500 ZEXEL

Isuzu 

105220-7500  
9 441 610 469 
NP-FP/KSP-A 
8973690000 
SUPPLY PUMP
F 01G 19U 002 
NP-FP/KSP-A 
 
SUPPLY PUMP
F 01G 19U 003 
NP-FP/KSP-A 
 
SUPPLY PUMP
9 441 610 557 
NP-FP/KSP-A 
 
SUPPLY PUMP
 
 

F 01G 19U 004 
NP-FP/KSP-AD 
 
SUPPLY PUMP

Isuzu 

9 441 610 439 
NP-FP/KSP-AD 
8973572640 
SUPPLY PUMP
9 441 610 439 
NP-FP/KSP-AD 
1157501990 
SUPPLY PUMP
9 441 610 457 
NP-FP/KSP-AD 
1157502030 
SUPPLY PUMP
9 441 610 473 
NP-FP/KSP-AD 
1157502080 
SUPPLY PUMP

Hino 

9 441 610 556 
NP-FP/KSP-AD 
225602970A 
SUPPLY PUMP
Back to top