Information injection-pump assembly
ZEXEL
101495-3591
1014953591
KOMATSU
6205711560
6205711560

Rating:
Service parts 101495-3591 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
19.6(200)
15.
NOZZLE SET
Cross reference number
ZEXEL
101495-3591
1014953591
KOMATSU
6205711560
6205711560
Zexel num
Bosch num
Firm num
Name
101495-3591
6205711560 KOMATSU
INJECTION-PUMP ASSEMBLY
S4D95LE-3 K
S4D95LE-3 K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-2-4-3
Pre-stroke
mm
3.2
3.15
3.25
Rack position
After adjusting injection quantity. R=A
After adjusting injection quantity. R=A
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cyl.1-2 deg. 90 89.5 90.5
Cyl.1-2 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cal 1-3 deg. 270 269.5 270.5
Cal 1-3 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
10.3
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
84.5
83.5
85.5
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
8+-0.5
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
13.5
12.5
14.5
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK CAP: R1
(4)Set idle sub-spring
----------
K=10 R1=(17.5)mm
----------
----------
K=10 R1=(17.5)mm
----------
Speed control lever angle

F:Full speed
I:Idle
(1)Set the pump speed at aa. ( At delivery )
(2)When pump speed set at bb
(3)Stopper bolt setting
(4)Use the hole above R = cc
----------
aa=910r/min bb=760r/min cc=60mm
----------
a=3deg+-5deg b=24deg+-5deg c=6deg+-5deg
----------
aa=910r/min bb=760r/min cc=60mm
----------
a=3deg+-5deg b=24deg+-5deg c=6deg+-5deg
Stop lever angle

N:Pump normal
S:Stop the pump.
(1)Rack position = aa, speed = bb (stamp at delivery)
(2)No return spring
----------
aa=3-0.5mm bb=0r/min
----------
a=22.5deg+-5deg b=(50deg)
----------
aa=3-0.5mm bb=0r/min
----------
a=22.5deg+-5deg b=(50deg)
0000001501 I/P WITH LOAD PLUNGER ADJ
Load plunger-equipped pump adjustment
1. Adjust the variation between cylinders and the injection quantity.
2. At Full point A, adjust the pre-stroke to the specified value.
3. After pre-stroke adjustment, reconfirm that the fuel injection quantity and the variation between cylinders is as specified.
----------
----------
----------
----------
Timing setting

(1)Pump vertical direction
(2)Position of key groove at No 1 cylinder's beginning of injection
(3)Stamp aligning marks on the pump housing flange.
(4)After adjusting the injection quantity, adjust at rack position aa.
(5)-
----------
aa=10.3mm
----------
a=58deg+-3deg b=2deg+-30min
----------
aa=10.3mm
----------
a=58deg+-3deg b=2deg+-30min
Information:
The cooling system consists of the water pump, two thermostats and lines and passages to direct the coolant throughout the engine.Coolant from the radiator bottom tank flows through two thermostats to the inlet side of the water pump. The centrifugal-type water pump mounts on the front cover and is belt driven by the crankshaft pulley. The pump has two outlets. Coolant from the outlet on the right side of the pump flows through a passage in the front cover to one side of the engine and coolant from the other outlet flows to the other side of the engine.The coolant circulates through the block to the cylinder heads. Coolant flows from the heads through connecting sleeves to the return manifold in the front cover. Orifices in the sleeves regulate the flow from the heads.
SHUNT COOLING SYSTEM (THERMOSTATS OPEN)Part of the coolant from the left bank is diverted from the block to the oil cooler. External lines direct coolant from the block, to the cooler and back to the return manifold in the front cover.An internal passage in the front cover directs coolant from the return manifold to the thermostats. If the thermostats are closed the coolant flows to the pump and is recirculated through the engine. If they are open, coolant flows from the return manifold to the radiator and from there to the pump. This engine must never be run without thermostats as coolant will not circulate through the radiator and this will cause rapid overheating.By using the shunt cooling system a positive head of coolant is maintained at the pump inlet to help prevent aeration and pump cavitation. It differs from the conventional cooling system in that the radiator top tank is divided into two compartments (upper and lower) with a small air/coolant bleed tube connecting them. A shunt line located as low as possible in the upper chamber connects it to the pump inlet.When the coolant reaches the temperature necessary to open the thermostats, coolant is directed from the bottom of the radiator through the thermostats, water pump, engine, radiator top tank and the radiator core. Coolant (and air which might be in the system) will flow through the small air/coolant bleed tube into the upper chamber. The volume of coolant which flows through the bleed tube from the lower chamber to the upper chamber will flow out the shunt line and to the pump inlet line.Air in the system vents through the bleed tube and remains in the upper chamber until it is vented out through the pressurized relief valve. The top tank temperature must never exceed 210°F (99°C).
SHUNT COOLING SYSTEM (THERMOSTATS OPEN)Part of the coolant from the left bank is diverted from the block to the oil cooler. External lines direct coolant from the block, to the cooler and back to the return manifold in the front cover.An internal passage in the front cover directs coolant from the return manifold to the thermostats. If the thermostats are closed the coolant flows to the pump and is recirculated through the engine. If they are open, coolant flows from the return manifold to the radiator and from there to the pump. This engine must never be run without thermostats as coolant will not circulate through the radiator and this will cause rapid overheating.By using the shunt cooling system a positive head of coolant is maintained at the pump inlet to help prevent aeration and pump cavitation. It differs from the conventional cooling system in that the radiator top tank is divided into two compartments (upper and lower) with a small air/coolant bleed tube connecting them. A shunt line located as low as possible in the upper chamber connects it to the pump inlet.When the coolant reaches the temperature necessary to open the thermostats, coolant is directed from the bottom of the radiator through the thermostats, water pump, engine, radiator top tank and the radiator core. Coolant (and air which might be in the system) will flow through the small air/coolant bleed tube into the upper chamber. The volume of coolant which flows through the bleed tube from the lower chamber to the upper chamber will flow out the shunt line and to the pump inlet line.Air in the system vents through the bleed tube and remains in the upper chamber until it is vented out through the pressurized relief valve. The top tank temperature must never exceed 210°F (99°C).
Have questions with 101495-3591?
Group cross 101495-3591 ZEXEL
Komatsu
Komatsu
Komatsu
101495-3591
6205711560
INJECTION-PUMP ASSEMBLY
S4D95LE-3
S4D95LE-3