Information injection-pump assembly
ZEXEL
101495-3360
1014953360

Rating:
Service parts 101495-3360 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
6207-11-3100
12.
Open Pre:MPa(Kqf/cm2)
19.6{200}
15.
NOZZLE SET
Cross reference number
ZEXEL
101495-3360
1014953360
Zexel num
Bosch num
Firm num
Name
101495-3360
INJECTION-PUMP ASSEMBLY
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-2-4-3
Pre-stroke
mm
3.6
3.55
3.65
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cyl.1-2 deg. 90 89.5 90.5
Cyl.1-2 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cal 1-3 deg. 270 269.5 270.5
Cal 1-3 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
9.8
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
32.6
31.6
33.6
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
9.3+-0.5
Pump speed
r/min
475
475
475
Average injection quantity
mm3/st.
10.5
9.5
11.5
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT: RAL
(4)The torque control spring must does not have a set force.
(5)Damper spring setting: DL
----------
K=18 RAL=15+0.2mm DL=7.3+-0.1mm
----------
----------
K=18 RAL=15+0.2mm DL=7.3+-0.1mm
----------
Speed control lever angle

F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=6deg+-5deg b=18deg+-5deg
----------
----------
a=6deg+-5deg b=18deg+-5deg
Stop lever angle

N:Pump normal
S:Stop the pump.
----------
----------
a=1deg+-5deg b=53deg+-5deg
----------
----------
a=1deg+-5deg b=53deg+-5deg
Timing setting

(1)Pump vertical direction
(2)Position of key groove at No 1 cylinder's beginning of injection
(3)Stamp aligning marks on the pump housing flange.
(4)-
----------
----------
a=59deg36min+-3deg b=0deg24min+-30min
----------
----------
a=59deg36min+-3deg b=0deg24min+-30min
Information:
Introduction
Procedure to prevent injector Plunger Spring failure due to inadequate fuel system priming.
The low-pressure fuel system must be primed after injector replacement or other repair to the low-pressure fuel system circuit which may allow air to enter the system.
Inadequate priming can result in air being present in the low-pressure fuel system and inside the injectors.
Attempting to start the engine without adequate priming may result in an early hour failure of the injector plunger spring.
Follow the procedure below to prevent injector failure due to inadequate priming.
DO NOT START THE ENGINE WITHOUT PRIMING THE FUEL SYSTEM
Illustration 1 g03735591
Damaged plunger spring due to improper fuel system primingFuel System Priming Procedure:
Disconnect the injector harness at the valve cover.
Use the hand primer to fill the fuel system. Pump until the hand primer becomes too hard to depress by hand.
Crank the engine 3 times for 15 seconds each. Reapply the hand primer after each cranking cycle.
Once the hand primer remains hard to depress after the 15 second crank, reconnect the injector harness and start the engine.
Clear any related fault codes (ET) that were logged while cranking the engine with the injector harness disconnected.
Illustration 2 g03736011
Procedure to prevent injector Plunger Spring failure due to inadequate fuel system priming.
The low-pressure fuel system must be primed after injector replacement or other repair to the low-pressure fuel system circuit which may allow air to enter the system.
Inadequate priming can result in air being present in the low-pressure fuel system and inside the injectors.
Attempting to start the engine without adequate priming may result in an early hour failure of the injector plunger spring.
Follow the procedure below to prevent injector failure due to inadequate priming.
DO NOT START THE ENGINE WITHOUT PRIMING THE FUEL SYSTEM
Illustration 1 g03735591
Damaged plunger spring due to improper fuel system primingFuel System Priming Procedure:
Disconnect the injector harness at the valve cover.
Use the hand primer to fill the fuel system. Pump until the hand primer becomes too hard to depress by hand.
Crank the engine 3 times for 15 seconds each. Reapply the hand primer after each cranking cycle.
Once the hand primer remains hard to depress after the 15 second crank, reconnect the injector harness and start the engine.
Clear any related fault codes (ET) that were logged while cranking the engine with the injector harness disconnected.
Illustration 2 g03736011
Have questions with 101495-3360?
Group cross 101495-3360 ZEXEL
Komatsu
Komatsu
Komatsu
Komatsu
101495-3360
INJECTION-PUMP ASSEMBLY