140213-0500 ZEXEL 9 411 617 106 BOSCH WIRE 9411617106 1402130500 8941289180


 

Information wire

BOSCH 9 411 617 106 9411617106
ZEXEL 140213-0500 1402130500
ISUZU 8941289180 8941289180
140213-0500 WIRE
Rating:
58
Buy WIRE 140213-0500 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
140213-0500 
9 411 617 106 
8941289180  ISUZU
WIRE
C 23XX WIRE PFR- parts PFR
140213-0500 
9 411 617 106 
131296533  ISUZU
WIRE
A C 23XX WIRE PFR- parts PFR
140213-0500 
9 411 617 106 
131296533  ISHIKAWAJIMA-S
WIRE
C 23XX WIRE PFR- parts PFR
140213-0500 
9 411 617 106 
1533151431  KUBOTA
WIRE
C 23XX WIRE PFR- parts PFR
140213-0500 
9 411 617 106 
3531016353A  KAWASAKI-HEAVY
WIRE
C 23XX WIRE PFR- parts PFR
140213-0500 
9 411 617 106 
920862002  KAWASAKI-HEAVY
WIRE
A C 23XX WIRE PFR- parts PFR
140213-0500 
9 411 617 106 
81185010000  TOYO-SHA
WIRE
C 23XX WIRE PFR- parts PFR




Information:


Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 43) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from the terminals (TS-28) (line 43) and (TS-31) (line 44), which are located on the terminal strip in the junction box.
Current from terminals (TS-28) (line 43) and (TS-31) (line 44) flows through the preregulator (PR) (line 48) or the fuse (F4) to the electric governor control.
When the engine flywheel is rotating, the current also flows through the electric governor actuator (EGA) (line 52). When a fault in the system causes the current to energize the slave relay (SR1), the following events occur in the electric circuit in order to stop the engine.
The slave relay (SR1) opens across the contacts (SR1-30) and (SR1-87a) (line 45). The relay closes across the contacts (SR1-30) and (SR1-87) (line 43).
When the circuit opens across contacts (SR1-30) and (SR1-87a), the current is stopped to the electric governor control.
Current to the electric governor actuator (EGA) is also stopped.
The mechanical spring load in the electric governor actuator (EGA) will now move the fuel control rod in order to stop fuel flow to the engine. Note: With the exception of the differences that are described in this section of the manual, all of the fault circuits in the electric protection system are identical for the 2301A Electric Governor Control and for the nonelectric governor control.
Illustration 5 g00292615
Junction Box Wiring for ETR protection system with OP, WT, and OS that does not require

Have questions with 140213-0500?





Group cross 140213-0500 ZEXEL

Isuzu 

140213-0500  
9 411 617 106 
8941289180 
WIRE
140213-0500  
9 411 617 106 
131296533 
WIRE

Ishikawajima-S 

140213-0500  
9 411 617 106 
131296533 
WIRE

Kubota 

140213-0500  
9 411 617 106 
1533151431 
WIRE

Kawasaki-Heavy 

140213-0500  
9 411 617 106 
3531016353A 
WIRE
140213-0500  
9 411 617 106 
920862002 
WIRE

Toyo-Sha 

140213-0500  
9 411 617 106 
81185010000 
WIRE
Back to top