Information union nut
BOSCH
9 411 610 106
9411610106
ZEXEL
139220-0200
1392200200
ISUZU
5157292850
5157292850

Rating:
Include in ###:
Cross reference number
Zexel num
Bosch num
Firm num
Name
139220-0200
9 411 610 106
5157292850 ISUZU
UNION NUT
C 90HY NUT Standard parts Others
C 90HY NUT Standard parts Others
139220-0200
9 411 610 106
228212060A HINO
UNION NUT
C 90HY NUT Standard parts Others
C 90HY NUT Standard parts Others
139220-0200
9 411 610 106
ME717962 MITSUBISHI
UNION NUT
C 90HY NUT Standard parts Others
C 90HY NUT Standard parts Others
139220-0200
9 411 610 106
19314T9300 NISSAN-DIESEL
UNION NUT
C 90HY NUT Standard parts Others
C 90HY NUT Standard parts Others
139220-0200
9 411 610 106
SL0124346 MAZDA
UNION NUT
C 90HY NUT Standard parts Others
C 90HY NUT Standard parts Others
Information:
Indicator Lamps
The MECP indicator lamps provide the following status information:
"SUMMARY SHUTDOWN"
"SUMMARY ALARM"
"PLC FAILURE"
"ENGINE PRELUBE"The lamps activate when the "HORN SILENCE/LAMP TEST" switch is placed in the LAMP TEST.
Illustration 5 g00562727
"SUMMARY SHUTDOWN" Indicator Lamp
The "SUMMARY SHUTDOWN" lamp displays the status of the engine protection shutdown system.A red "SUMMARY SHUTDOWN" lamp indicates that a engine protection shutdown has occurred. The exact shutdown is annunciated on the PC window. A flashing "SUMMARY SHUTDOWN" lamp indicates an shutdown that is not acknowledged. A solid "SUMMARY SHUTDOWN" lamp indicates that the shutdown has been acknowledged.The cause of the shutdown is provided by the display screen. To acknowledge the indicator, turn the "HORN SILENCE/LAMP TEST" switch to the "HORN SILENCE" position. Correct the condition before restarting the engine. The control panel must be reset before the engine can be restarted. To reset the control panel, turn the "OFF/RESET, LOCAL, and REMOTE" switch to the "OFF/RESET" position. The air shutoff is activated for any shutdown. The air shutoff must also be reset before the engine can be restarted. If an overspeed shutdown occurs, the Engine Speed Switch must also be reset.Note: When a shutdown occurs the air damper closes. This secures the intake air. The air damper must be reset in order to start the engine. "SUMMARY ALARM" Indicator Lamp
The "SUMMARY ALARM" lamp provides a summary of the active MMS alarms. A red "SUMMARY ALARM" lamp indicates an alarm condition. Specific information on the alarm is provided on the PC window. A flashing "SUMMARY ALARM" lamp indicates an alarm that has not been acknowledged. A solid "SUMMARY ALARM" lamp indicates that the alarm has been acknowledged. The lamp will remain illuminated until the alarm condition is resolved."PLC FAILURE" Indicator Lamp
The "PLC FAILURE" lamp provides status of the PLC timer.The programmable logic control regularly sends a signal to a timer. If the timer fails to receive the signal, the yellow "PLC FAILURE" lamp illuminates. This indicates that the programmable logic control may not be providing full protection for the engine. Running the engine during abnormal conditions may cause engine damage.In the event of a PLC failure, the redundant relay logic shutdown system will provide minimum protection. The PLC failure should be corrected as soon as possible. While the "PLC FAILURE" lamp is illuminated the PC display may not be correct. Use the backup gauges for accurate information. If the programmable logic control is inoperative, the redundant shutdown system will provide minimum protection.PLC failure may be caused by the mode. Loss of the 24 Volt DC power may also cause a PLC failure. The system must be in the run mode.The "PLC FAILURE" lamp is illuminated and the "SUMMARY ALARM" lamp is flashing. Wait for five seconds. Count the number of flashes. The number of flashes corresponds to the slot that contains a faulty module."ENGINE PRELUBE" Indicator Lamp
The "ENGINE PRELUBE" lamp provides the status of engine lubrication.A green "ENGINE PRELUBE" lamp indicates that the engine is prelubed and that the engine is ready to start. Place the "PRELUBE-RUN-START"
The MECP indicator lamps provide the following status information:
"SUMMARY SHUTDOWN"
"SUMMARY ALARM"
"PLC FAILURE"
"ENGINE PRELUBE"The lamps activate when the "HORN SILENCE/LAMP TEST" switch is placed in the LAMP TEST.
Illustration 5 g00562727
"SUMMARY SHUTDOWN" Indicator Lamp
The "SUMMARY SHUTDOWN" lamp displays the status of the engine protection shutdown system.A red "SUMMARY SHUTDOWN" lamp indicates that a engine protection shutdown has occurred. The exact shutdown is annunciated on the PC window. A flashing "SUMMARY SHUTDOWN" lamp indicates an shutdown that is not acknowledged. A solid "SUMMARY SHUTDOWN" lamp indicates that the shutdown has been acknowledged.The cause of the shutdown is provided by the display screen. To acknowledge the indicator, turn the "HORN SILENCE/LAMP TEST" switch to the "HORN SILENCE" position. Correct the condition before restarting the engine. The control panel must be reset before the engine can be restarted. To reset the control panel, turn the "OFF/RESET, LOCAL, and REMOTE" switch to the "OFF/RESET" position. The air shutoff is activated for any shutdown. The air shutoff must also be reset before the engine can be restarted. If an overspeed shutdown occurs, the Engine Speed Switch must also be reset.Note: When a shutdown occurs the air damper closes. This secures the intake air. The air damper must be reset in order to start the engine. "SUMMARY ALARM" Indicator Lamp
The "SUMMARY ALARM" lamp provides a summary of the active MMS alarms. A red "SUMMARY ALARM" lamp indicates an alarm condition. Specific information on the alarm is provided on the PC window. A flashing "SUMMARY ALARM" lamp indicates an alarm that has not been acknowledged. A solid "SUMMARY ALARM" lamp indicates that the alarm has been acknowledged. The lamp will remain illuminated until the alarm condition is resolved."PLC FAILURE" Indicator Lamp
The "PLC FAILURE" lamp provides status of the PLC timer.The programmable logic control regularly sends a signal to a timer. If the timer fails to receive the signal, the yellow "PLC FAILURE" lamp illuminates. This indicates that the programmable logic control may not be providing full protection for the engine. Running the engine during abnormal conditions may cause engine damage.In the event of a PLC failure, the redundant relay logic shutdown system will provide minimum protection. The PLC failure should be corrected as soon as possible. While the "PLC FAILURE" lamp is illuminated the PC display may not be correct. Use the backup gauges for accurate information. If the programmable logic control is inoperative, the redundant shutdown system will provide minimum protection.PLC failure may be caused by the mode. Loss of the 24 Volt DC power may also cause a PLC failure. The system must be in the run mode.The "PLC FAILURE" lamp is illuminated and the "SUMMARY ALARM" lamp is flashing. Wait for five seconds. Count the number of flashes. The number of flashes corresponds to the slot that contains a faulty module."ENGINE PRELUBE" Indicator Lamp
The "ENGINE PRELUBE" lamp provides the status of engine lubrication.A green "ENGINE PRELUBE" lamp indicates that the engine is prelubed and that the engine is ready to start. Place the "PRELUBE-RUN-START"
Have questions with 139220-0200?
Group cross 139220-0200 ZEXEL
Isuzu
139220-0200
9 411 610 106
5157292850
UNION NUT
Hino
139220-0200
9 411 610 106
228212060A
UNION NUT
Mitsubishi
139220-0200
9 411 610 106
ME717962
UNION NUT
Nissan-Diesel
139220-0200
9 411 610 106
19314T9300
UNION NUT
Mazda
139220-0200
9 411 610 106
SL0124346
UNION NUT