139210-0200 ZEXEL 9 411 611 116 BOSCH UNION NUT 9411611116 1392100200 1156193370


 

Information union nut

BOSCH 9 411 611 116 9411611116
ZEXEL 139210-0200 1392100200
ISUZU 1156193370 1156193370
139210-0200 UNION NUT
Rating:
61
Buy UNION NUT 139210-0200 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
139210-0200 
9 411 611 116 
1156193370  ISUZU
UNION NUT
C 90HY NUT Standard parts Others
139210-0200 
9 411 611 116 
228212850A  HINO
UNION NUT
C 90HY NUT Standard parts Others
139210-0200 
9 411 611 116 
S228212850A  HINO
UNION NUT
A C 90HY NUT Standard parts Others
139210-0200 
9 411 611 116 
ME723583  MITSUBISHI
UNION NUT
C 90HY NUT Standard parts Others
139210-0200 
9 411 611 116 
1674799003  NISSAN-DIESEL
UNION NUT
C 90HY NUT Standard parts Others




Information:

Test 1 - Overspeed Switch (OS)
Table 1
Overspeed Switch (OS)
Step Engine RPM Action Correct Result
A 25 + 5 rpm less than 75% Overspeed Verify rpm Press the 75% Verify button No engine shutdown
B 25 + 5 rpm more than 75% Overspeed Verify rpm Press the 75% Verify button Air and fuel shutoff
C Manually reset the air shutoff lever at the top of the air inlet, if equipped. Press the ESS reset button. Test 2 - Emergency Stop Switch (ES)
Table 2
Emergency Stop Switch (ES)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Press the push button for the emergency stop switch Air and fuel shutoff
B Manually reset the air shutoff lever at the top of the air inlet, if equipped. Turn ES switch in the dirction that is shown on the face of the push button in order to reset the switch. Test 3 - Normal Stop Switch (NSS)
Table 3
Normal Stop Switch (NSS)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Push the normal stop switch (NSS) Fuel shutoff Test 4 - Water Temperature Contactor Switch
Table 4
Water Temperature Contactor Switch (WTS)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Place a jumper across terminals TS-2 and TS-7. Fuel shutoff
B Remove the jumper from terminals TS-2 and TS-7. Test 5 - Oil Pressure Switch (OPS1)
Table 5
Oil Pressure Switch (OPS1)
Step Engine RPM Action Correct Result
A Any rpm above the crank terminate rpm Place a jumper across terminals OPS1-1 and OPS1-3. Fuel shutoff
B Remove the jumper from terminals OPS1-1 and OPS1-3. Test 6 - Oil Pressure Switch (OPS2)
Table 6
Oil Pressure Switch (OPS2)
Step Engine RPM Action Correct Result
A 25 + 5 rpm less than the setting for the oil step speed Place a jumper across terminals OPS2-1 and OPS2-3. No engine shutdown.
B 25 + 5 rpm more than the setting for the oil step speed Place a jumper across terminals OPS2-1 and OPS2-3. Fuel shutoff 9 seconds after the oil step speed is reached.
C Remove the jumper from across terminals OPS2-1 and OPS2-3.

Have questions with 139210-0200?





Group cross 139210-0200 ZEXEL

Isuzu 

139210-0200  
9 411 611 116 
1156193370 
UNION NUT

Hino 

139210-0200  
9 411 611 116 
228212850A 
UNION NUT
139210-0200  
9 411 611 116 
S228212850A 
UNION NUT

Mitsubishi 

139210-0200  
9 411 611 116 
ME723583 
UNION NUT

Nissan-Diesel 

139210-0200  
9 411 611 116 
1674799003 
UNION NUT
Back to top