Buy 105248-0150 ZEXEL 9 440 610 015 BOSCH SUPPLY PUMP 9440610015 1052480150 5157500300


 

Information supply pump

BOSCH 9 440 610 015 9440610015
ZEXEL 105248-0150 1052480150
ISUZU 5157500300 5157500300
105248-0150 SUPPLY PUMP
Rating:
8
Buy SUPPLY PUMP 105248-0150 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
£176.73
 

03 Mar 2018

Bosch: Bosch
Bosch 9440610015 Supply Pump

Scheme ###:

1. [1] 152004-0700 PUMP HOUSING
2. [1] 152020-0900 COVER
3. [1] 152111-1700 TAPPET
4. [1] 029403-0240 BEARING PIN
5. [1] 152110-1000 COILED SPRING
6. [1] 152133-0100 COILED SPRING
7. [1] 152130-0220 DIAPHRAGM
8. [2] 152119-0020 VALVE BODY
8. [2] 152119-0020 VALVE BODY
9. [1] 152140-0200 RETAINER
10. [2] 020104-0840 BLEEDER SCREW
13. [4] 020105-1640 BLEEDER SCREW M5P0.8L16
15. [2] 029341-4070 GASKET
15. [2] 029341-4070 GASKET
16. [1] 029730-8010 EYE BOLT
17. [1] 029730-8010 EYE BOLT
18. [1] 029710-8100 INLET UNION
19. [1] 029710-8100 INLET UNION
20. [2] 029330-8080 GASKET
21. [2] 029330-8080 GASKET
30. [1] 152210-0620 CONTROL LEVER
31. [1] 029630-8080 O-RING
32. [1] 152210-0500 LOCKING WASHER
33. [1] 152210-0400 COILED SPRING

Cross reference number

Zexel num
Bosch num
Firm num
Name
105248-0150 
9 440 610 015 
5157500300  ISUZU
SUPPLY PUMP
K 14GC FEED PUMP F/P
105248-0150 
9 440 610 015 
1305060500  ISHIKAWAJIMA-S
SUPPLY PUMP
K 14GC FEED PUMP F/P




Information:


Illustration 39 g00367353
Set the drive speed to "Col 4". Place a straight edge across the opening in the shutdown rod and the shutdown rod nut (F). Use a 7/16 inch open end wrench in order to turn the shutdown rod nut (F) counterclockwise until the governor begins to shut down. Once the governor begins to shut down, turn the nut clockwise one full turn.Adjustment Of The Shutdown Device
Note: The electric shutdown device and the pressure shutdown device should be checked prior to the installation, after the installation, and at 1000 hour intervals thereafter.
Failure to test, inspect and maintain these items could result in faulty operation and possible severe engine damage if an emergency shutdown situation occurs.
The electric shutdown is either an Energize-To-Shutoff (ETS) or an Energize-To-Run (ETR). Identify the type of shutdown device in your governor, and make a note of the type of shutdown device.
Visually inspect the pressure shutdown components for signs of burrs, nicks, scoring and/or wear. Repair the components if evidence of a problem exists. Inspect the pressure shutdown gasket. Determine if the gasket is reusable. If necessary, replace the gasket.
Illustration 40 g00367319
(F) Shutdown Rod Nut. (J) Shutdown Rod. (II) Solenoid. (JJ) Jam Nut. (KK) Set Screw. (LL) Shutdown Plunger. (MM) Solenoid Plunger. (NN) Pivot Pin. (PP) Shutdown Lever.
Visually inspect the electric shutdown device and determine if there is any component wear. If the shutdown is an ETS version, pay particular attention to the connection of the shutdown solenoid's plunger and the shutdown lever's link pin.If there is evidence of wear, replace the solenoid. Inspect the gasket on the electric shutdown. Determine if the gasket is reusable. If necessary, replace the gasket.Check the size of spacer on the solenoid plunger in the electric shutdown. Refer to the Service Magazine Article November 19,, "Field Replacement of Spacer to Correct Possible Sticking in Woodward 3161 Governor Electric Shutoff Group".Adjustment Of The Electric Shutdown Solenoid
Energize-To-Shutoff (ETS)
Place the housing of the electric shutdown in a vise. Use copper jaws or shop towels in order to protect the sides of the aluminum die cast housing. Do NOT excessively tighten the vise.Loosen the jam nut (JJ) that holds the solenoid in the electric shutdown's housing. Remove the solenoid coil (II) in order to expose the shutdown plunger (MM) .Note: Loctite 222 is used on the threads of the solenoid coil during manufacturing. In addition, the jam nut is tightened to a torque of 75 N m (55.5 lb ft).
Carefully clean any dirt, metal filings or metal chips from the solenoid plunger and from the cavity in the solenoid coil. Turn the jam nut on the solenoid coil so that the nut will not interfere with the adjustment of the solenoid coil. Reinstall the solenoid coil in the electric shutdown's housing by turning the coil four times.
Hold the housing and the gasket on a

Have questions with 105248-0150?





Group cross 105248-0150 ZEXEL

Isuzu 

9 440 610 703 
5157500050 
SUPPLY PUMP
9 440 610 035 
5157500060 
SUPPLY PUMP
9 440 610 767 
 
SUPPLY PUMP
9 440 611 000 
 
SUPPLY PUMP

Isuzu 

105248-0150  
9 440 610 015 
5157500300 
SUPPLY PUMP

Ishikawajima-S 

105248-0150  
9 440 610 015 
1305060500 
SUPPLY PUMP
9 440 610 768 
 
SUPPLY PUMP
9 440 611 001 
 
SUPPLY PUMP

Ishikawajima-S 

9 440 610 769 
130506080 
SUPPLY PUMP

Nissan-Diesel 

 
16640Z7001 

Back to top