105237-6510 ZEXEL 9 440 610 633 BOSCH SUPPLY PUMP 9440610633 1052376510


 

Information supply pump

BOSCH 9 440 610 633 9440610633
ZEXEL 105237-6510 1052376510
105237-6510 SUPPLY PUMP
Rating:
74
Buy SUPPLY PUMP 105237-6510 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152060-0020 PUMP HOUSING
2. [1] 152030-0400 STOP PIN
5. [1] 152100-2301 PUMP PLUNGER
6. [1] 152102-2400 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 139526-0000 GASKET
14. [4] 152115-0500 VALVE BODY
14. [4] 152115-0500 VALVE BODY
15. [4] 152116-0200 COILED SPRING
15. [4] 152116-0200 COILED SPRING
16. [3] 152117-0620 CAPSULE
18. [4] 029631-6060 O-RING
18. [4] 029631-6060 O-RING
25. [1] 152200-6720 HAND PRIMER
30. [1] 152300-3620 EYE BOLT
32. [1] 029731-4570 EYE BOLT
33. [1] 152350-8300 PIPE
35. [2] 139514-0300 GASKET
36. [2] 139514-0300 GASKET

Include in #1:

107691-3351 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105237-6510 
9 440 610 633 
   
SUPPLY PUMP
* K 14GC F/P




Information:


To avoid possible engine damage or another immediate shutdown, the water temperature fault must be corrected before attempting to restart the engine.
Even though the starter motor circuit can now be engaged, there is no fuel flow to the engine. The fuel flow to the engine is stopped until the coolant temperature falls below the rating for the water temperature contactor switch (WTS). When the coolant temperature falls below the rating for the water temperature contactor switch (WTS), the contactor switch opens again. The fuel shutoff solenoid is de-energized when the switch reopens. This allows fuel flow to the engine. The engine can then be restarted.2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 43) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from the terminals (TS-28) (line 43) and (TS-31) (line 44), which are located on the terminal strip in the junction box.
Current from terminals (TS-28) (line 43) and (TS-31) (line 44) flows through the preregulator (PR) (line 48) or the fuse (F4) to the electric governor control.
When the engine flywheel is rotating, the current also flows through the electric governor actuator (EGA) (line 52). When a fault in the system causes the current to energize the slave relay (SR1), the following events occur in the electric circuit in order to stop the engine.
The slave relay (SR1) opens across the contacts (SR1-30) and (SR1-87a) (line 45). The relay closes across the contacts (SR1-30) and (SR1-87) (line 43).
When the circuit opens across contacts (SR1-30) and (SR1-87a), the current is stopped to the electric governor control.
Current to the electric governor actuator (EGA) is also stopped.
The mechanical spring load in the electric governor actuator (EGA) will now move the fuel control rod in order to stop fuel flow to the engine.Note: With the exception of the differences that are described in this section of the manual, all of the fault circuits in the electric protection system are identical for the 2301A Electric Governor Control and for the nonelectric governor control.
Illustration 5 g00292456
Junction Box Wiring for ETS with OP, WT, and OS that does not require a switchgear for use on 3200 through 3400 Engines
Illustration 6 g00292457
JIC Schematic for ETS with OP, WT, and OS that does not require a switchgear for use on 3200 through 3400 Engines
Illustration 7 g00292458
IEC Schematic for ETS with OP, WT, and OS that does not require a switchgear for use on 3200 through 3400 Engines
Illustration 8 g00292474
6I-1862 Wiring Harness for ETS with OP, WT, and OS that does not require a switchgear for use on 3200 through 3400 Engines
Illustration 9 g00292459
Junction Box Wiring for ETS with OP, WT, and OS that does not require a switchgear for

Have questions with 105237-6510?





Group cross 105237-6510 ZEXEL

Isuzu 

9 440 610 654 
1157501830 
SUPPLY PUMP
9 440 611 004 
NP-FP/KDP-MD 
 
SUPPLY PUMP
105237-6510  
9 440 610 633 
 
SUPPLY PUMP

Hino 

9 440 610 662 
225602720A 
SUPPLY PUMP
9 440 610 850 
NP-FP/KDP-MD 
 
SUPPLY PUMP

Hino 

9 440 610 648 
NP-FP/KDP-MD 
225602810A 
SUPPLY PUMP
 
 

 
 

Back to top