105237-4431 ZEXEL 9 440 610 975 BOSCH SUPPLY PUMP 9440610975 1052374431 1157501311


 

Information supply pump

BOSCH 9 440 610 975 9440610975
ZEXEL 105237-4431 1052374431
ISUZU 1157501311 1157501311
105237-4431 SUPPLY PUMP
Rating:
36
Buy SUPPLY PUMP 105237-4431 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152004-5020 PUMP HOUSING
5. [1] 152100-1120 PUMP PLUNGER
6. [1] 152102-1300 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 029332-6030 GASKET
10. [1] 152111-4020 TAPPET
10/2. [1] 152112-0500 ROLLER
10/3. [1] 152113-1000 BEARING PIN
10/4. [2] 152114-1700 SLIDER
14. [4] 152115-0500 VALVE BODY
14. [4] 152115-0500 VALVE BODY
14. [4] 152115-0500 VALVE BODY
15. [4] 152116-0200 COILED SPRING
15. [4] 152116-0200 COILED SPRING
15. [4] 152116-0200 COILED SPRING
16. [2] 152117-0620 CAPSULE
17. [1] 152118-1700 ADAPTOR
18. [4] 029631-6060 O-RING
18. [4] 029631-6060 O-RING
20. [1] 152121-0400 LOCKING WASHER
25. [1] 152200-6721 HAND PRIMER
30. [1] 152300-5520 EYE BOLT
35. [2] 139514-0000 GASKET D19.2&14.2T1.0
49. [1] 139814-0000 EYE BOLT
51. [2] 139514-0000 GASKET D19.2&14.2T1.0

Include in #1:

106991-1234 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105237-4431 
9 440 610 975 
NP-FP/KD-PS 
1157501311  ISUZU
SUPPLY PUMP
A K 14GC FEED PUMP F/P




Information:


Figure 1The next chart shows maximum acceptable voltage loss in the high current battery circuit feeding the starting motor. These values are maximums for machines of approximately 2000 SMH and up. Newer machines would be less than those shown.
Figure 2Voltages greater than those shown are most often caused by loose and/or corroded connections or defective switch contacts.Diagnosis Procedure
Do not operate the starting motor for more than 30 seconds at a time. After 30 seconds, the cranking must be stopped for two minutes to allow the starting motor to cool. This will prevent damage to the starting motor due to excessive heat buildup.
If the starting motor cranks real slow or does not crank at all, do the following procedure:1. Measure battery voltage at the battery posts with the multimeter while cranking or attempting to crank the engine. Make sure to measure the battery posts. Do not measure the cable post clamps.2. Is battery voltage equal to or greater than shown in Figure 1? a. If the battery voltage is OK, go to Step 3.b. If the battery voltage is too low, test the battery as shown in Special Instruction Form No. SEHS7633. A low battery can be caused by battery condition or a shorted starting motor.3. Measure current draw on the (+) battery cable between the battery and the starting motor solenoid with the clamp-on ammeter. The maximum current draw allowed is shown in Specifications under Load Test. The figures shown in Specifications are taken at temperature of 27°C (80°F). At temperatures below 27°C (80°F), the voltage will be less and the current draw will be higher. If current draw is too much, the starting motor has a problem and must be removed for repair or replacement. If voltage at the battery post is within approximately 2 volts of the lowest value in the applicable temperature range of Figure 1 and if the large starting motor cables get hot, then the starting motor has a problem and the 8T0900 Ammeter test is not needed.4. Measure starting motor voltage from test point (4) to (5) with the multimeter while cranking or attempting to crank the engine.5. Is voltage equal to or greater than shown in Figure 1? a. If the starting motor voltage is OK, the battery and starting motor cables down to the motor are within specifications. Go to Step 8.b. If the starting motor voltage is low, the voltage drop between the battery and the starting motor is too great. Go to Step 6.6. Measure the voltage drops in the cranking circuits with the multimeter. Compare the results with maximum voltage drops allowed in Figure 2.7. Are all the voltages within specifications? a. If the voltage drops are OK, go to Step 8, to check the engine.b. If the voltage drops are too high, repair and/or replace the faulty electrical component.8. Rotate the crankshaft by hand to make sure it is not locked up. Check oil viscosity and any external loads that would affect engine rotation.9. Is the

Have questions with 105237-4431?





Group cross 105237-4431 ZEXEL

9 440 610 547 
NP-FP/KD-P 
 
SUPPLY PUMP

Hino 

9 440 610 160 
NP-FP/KD-PT 
225601990A 
SUPPLY PUMP
9 440 610 160 
NP-FP/KD-PT 
S225601990A 
SUPPLY PUMP
9 440 610 310 
 
SUPPLY PUMP

Isuzu 

9 440 610 824 
NP-FP/KD-P 
1157501300 
SUPPLY PUMP
9 440 610 452 
1157501310 
SUPPLY PUMP
105237-4431  
9 440 610 975 
NP-FP/KD-PS 
1157501311 
SUPPLY PUMP
9 440 610 453 
1157501330 
SUPPLY PUMP
9 440 610 920 
NP-FP/KD-P 
1157501331 
SUPPLY PUMP
9 440 610 454 
1157501340 
SUPPLY PUMP
9 440 610 960 
NP-FP/KD-P 
1157501341 
SUPPLY PUMP
9 440 610 569 
 
SUPPLY PUMP

Niigata-Urawa 

9 440 610 570 
V1N47131A 
SUPPLY PUMP
9 440 610 388 
NP-FP/KD-PS 
 
SUPPLY PUMP

Hino 

9 440 610 388 
NP-FP/KD-PS 
225602030A 
SUPPLY PUMP

Isuzu 

9 440 610 311 
NP-FP/KD-PS 
1157501350 
SUPPLY PUMP
9 440 610 948 
NP-FP/KD-PT 
 
SUPPLY PUMP
Back to top