105220-7320 ZEXEL 9 441 610 555 BOSCH SUPPLY PUMP 9441610555 1052207320 8973572350


 

Information supply pump

BOSCH 9 441 610 555 9441610555
ZEXEL 105220-7320 1052207320
ISUZU 8973572350 8973572350
105220-7320 SUPPLY PUMP
Rating:
79
Buy SUPPLY PUMP 105220-7320 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152062-0120 PUMP HOUSING
2. [1] 152030-0200 STOP PIN
5. [1] 152100-2301 PUMP PLUNGER
6. [1] 152102-0600 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 139526-0000 GASKET
14. [2] 152115-0500 VALVE BODY
14. [2] 152115-0500 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
17. [1] 152118-0900 ADAPTOR
18. [2] 029631-6060 O-RING
18. [2] 029631-6060 O-RING
25. [1] 152200-6720 HAND PRIMER
30. [1] 152300-7720 EYE BOLT
32. [1] 152300-7720 EYE BOLT
35. [3] 029341-4080 GASKET
36. [3] 029341-4080 GASKET

Include in #1:

101402-8150 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105220-7320 
9 441 610 555 
NP-FP/KSP-A 
8973572350  ISUZU
SUPPLY PUMP
A K 14GC FEED PUMP F/P




Information:

Proper operation and maintenance are key factors in obtaining the maximum life and economy of the engine. Following the directions in this manual will lower operating costs.The time needed for the engine to reach the normal mode of operation is usually less than the time taken for a walk-around-inspection of the engine.After the engine is started and the cold low idle operation is completed, the engine can be operated at rated speed and low power. The engine will reach normal operating temperature faster when operated at rated speed and low power demand than when idled at no load. Typically the engine should be up to operating temperature in a few minutes.Governors and Actuators
Your engine may be equipped with a:* full-range governor* Woodward PSG Governor* Woodward 1724 Actuator* Woodward 524 Actuator
PSG Actuator
1724/524 ActuatorWoodward Governors/Actuators are usually electrically operated from a control panel. The application is usually an EPG power generator set. On standby gen sets the governor may be set to operate only at Full Load Speed.Change Engine Speed
If equipped with a control panel, a RAISE/LOWER switch or a speed setting potentiometer is used to adjust the operating speed.Starting, Operating and Stopping Engines Equipped with Control Panels
For all information regarding the generator control panel used for starting, operating and stopping the engine, refer to the Engine Protection Devices Generator Set Control Panel topic in this publication or Caterpillar SR4 Generators and Control Panels, SEBU6150. Additional information and programming instructions are provided in the Service Manual for your specific control panel.Mechanical Governors (If Equipped)
Governor Control LeverYour engine may be equipped with a full-range governor. Most other manufacturers' engines have min-max type governors that only govern at high and low idle to prevent the engine from overspeeding or dying. With the min-max governor, the position of the speed lever determines the amount of fuel delivered to the engine.With the full-range governor, the position of the speed lever sets engine speed and helps hold a constant speed independent of load which makes operation easier.The governor control motor is a 24 volt motor which allows for engine speed control from a remote location through a governor RAISE/LOWER switch. This governor control switch is used with the optional EMCP II. Always increase engine speed to high idle before applying load.For information regarding initial checks and adjustments, refer to the Service Manual or contact your Caterpillar dealer.Driven Equipment Without Load
1. Move the governor control lever to half engine speed.2. Interrupted starts put excessive stress on the drive train and waste fuel. To get the driven equipment in motion, engage the clutch smoothly, with no load on the equipment. This should result in a smooth, easy start without increasing the engine speed above low idle or slipping the clutch. For generator sets, move the governor control to high idle (full load) position (1800 rpm for 60 Hz and 1500 rpm for 50 Hz).3. Apply the load and check the gauges and equipment for proper operation. Begin operating the engine at low load. After normal oil pressure

Have questions with 105220-7320?





Group cross 105220-7320 ZEXEL

Isuzu 

9 441 610 436 
NP-FP/KSP-A 
8973572650 
SUPPLY PUMP
9 441 610 644 
NP-FP/KSP-A 
8980253480 
SUPPLY PUMP
105220-7320  
9 441 610 555 
NP-FP/KSP-A 
8973572350 
SUPPLY PUMP
9 441 610 645 
NP-FP/KSP-A 
 
SUPPLY PUMP

Isuzu 

9 441 610 461 
NP-FP/KSP-A 
8973572660 
SUPPLY PUMP
9 441 610 435 
NP-FP/KSP-A 
8973682750 
SUPPLY PUMP
9 441 610 646 
NP-FP/KSP-A 
 
SUPPLY PUMP

Isuzu 

9 441 610 467 
NP-FP/KSP-A 
8973654850 
SUPPLY PUMP
9 441 610 468 
NP-FP/KSP-A 
8973840890 
SUPPLY PUMP
9 441 610 566 
NP-FP/KSP-A 
1157502060 
SUPPLY PUMP
Back to top