Buy 105220-7060 ZEXEL 9 441 610 202 BOSCH SUPPLY PUMP 9441610202 1052207060 1664095008


 

Information supply pump

BOSCH 9 441 610 202 9441610202
ZEXEL 105220-7060 1052207060
NISSAN-DIESEL 1664095008 1664095008
105220-7060 SUPPLY PUMP
Rating:
52
Buy SUPPLY PUMP 105220-7060 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$91.00

05 Mar 2025

CN: Xiehaparts
Haiyazhma Fuel Pump 105220-5740 105220-7060 1052205740 Compatible with Hitachi Excavator EX60-5
Haiyazhma Part Name: Fuel Pump || Part Number: 105220-5740 105220-7060 1052205740 Note: Please check the fitment carefully before purchase. Or just tell us the part number you need. || Applicable: Compatible with Hitachi Excavator EX60-5 || Package included: 1pcs Fuel Pump 105220-5740 105220-7060 1052205740 || Note: Please compare its appearance shape and size with your original unit and make sure that it can fit your machine before ordering.

Scheme ###:

1. [1] 152062-0020 PUMP HOUSING
2. [1] 152030-0300 STOP PIN
5. [1] 152100-2301 PUMP PLUNGER
6. [1] 152102-0400 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 139526-0000 GASKET
14. [2] 152115-0500 VALVE BODY
14. [2] 152115-0500 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
17. [1] 152118-0900 ADAPTOR
18. [2] 029631-6060 O-RING
18. [2] 029631-6060 O-RING
25. [1] 152200-6720 HAND PRIMER
30. [1] 152300-7520 EYE BOLT
32. [1] 029731-4680 EYE BOLT

Cross reference number

Zexel num
Bosch num
Firm num
Name
105220-7060 
9 441 610 202 
NP-FP/KSP-AD 
1664095008  NISSAN-DIESEL
SUPPLY PUMP
K 14GC FEED PUMP F/P




Information:


Do not engage starter when flywheel is turning.Do not start engine under load.
Above 0°C (32°F)
1. Place the transmission or other power takeoff attachments in NEUTRAL. For air start systems; check the air supply before starting the engine. There must be 690 kPa (100 psi) air pressure available.2. Move governor control lever (throttle) or depress the accelerator to half engine speed position.3. Turn the battery disconnect switch (if equipped) to the ON position. 4. Push the air start knob (1) IN, or ... ... turn the start switch (2) for marine, industrial and generator set engines or ... ... turn the start switch (3) for machines (vehicles) to the START position.
Do not crank the engine for more than 30 seconds. Allow 2 minutes for the starter to cool before cranking again. If oil pressure does not rise within 15 seconds after the engine starts, stop the engine and make necessary corrections.
5. Release the start switch or air start knob when the engine starts.6. Do not apply load to the engine or increase engine speed until oil pressure and all temperature gauges reach operating temperature. Check all gauges during the warm-up period.Below 0°C (32°F)
Ether is poisonous and flammable.Do not store replacement cylinders in living areas or in the operator's compartment.Do not smoke while changing ether cylinders.Use ether only in well ventilated areas.Use it with care to avoid fires.Avoid breathing of the vapors or repeated contact of ether with skin.Do not puncture or burn cylinders.Discard cylinders in a safe place.Keep ether container away from heat, sparks, open flame, or open sunlight. It may explode.Do not store replacement cylinders at temperatures above 49°C (120°F).Do not use cylinders in environments above 93°C (200°F).
1. Depress ether switch and hold for 3 seconds, then release. For air start system; check the air supply before starting the engine. There must be 690 kPa (100 psi) air pressure available.2. Push the air start knob IN or turn the start switch for engines, or turn the start switch for machines (vehicles) to the START position.3. Begin cranking the engine, and depress ether switch and hold for 3 seconds then release. Additional injections of ether may be required to start and/or achieve low idle speed.4. Operate the engine at low speed and/or load until all systems reach operating temperatures. Check all gauges during the warmup period.
Do not use excessive starting fluid during starting or after the engine is running. Do not crank the engine for more than 30 seconds. Allow 2 minutes for the starter motor to cool before cranking again.If oil pressure does not rise within 15 seconds after the engine starts, stop the engine and make necessary corrections.
Turn the battery disconnect switch (if equipped) OFF after the engine is stopped to prevent battery discharge while starter motor is cooling.For starting below -18°C (0°F), use of optional cold weather starting aids are recommended. A coolant heater or extra battery capacity may be required.For temperatures below -23°C (-10°F), consult your Caterpillar dealer or refer to the "Cold Weather Operation

Have questions with 105220-7060?





Group cross 105220-7060 ZEXEL

 
 

Nissan-Diesel 

9 441 610 239 
NP-FP/KSP-AD 
16640Z5569 
SUPPLY PUMP

Nissan 

9 441 610 240 
NP-FP/KSP-A 
16640Z5568 
SUPPLY PUMP

Nissan-Diesel 

9 441 610 240 
NP-FP/KSP-A 
16640Z5568 
SUPPLY PUMP
9 441 610 220 
NP-FP/KSP-A 
 
SUPPLY PUMP

Yanmar 

9 441 610 266 
NP-FP/KSP-AD 
12760552100 
SUPPLY PUMP

Nissan-Diesel 

9 441 610 188 
NP-FP/KSP-A 
16640Z5571 
SUPPLY PUMP
105220-7060  
9 441 610 202 
NP-FP/KSP-AD 
1664095008 
SUPPLY PUMP
9 441 610 565 
NP-FP/KSP-A 
 
SUPPLY PUMP
F 01G 19U 001 
NP-FP/KSP-A 
 
SUPPLY PUMP
9 441 610 221 
NP-FP/KSP-AD 
 
SUPPLY PUMP