105220-7030 ZEXEL 9 441 610 220 BOSCH SUPPLY PUMP 9441610220 1052207030


 

Information supply pump

BOSCH 9 441 610 220 9441610220
ZEXEL 105220-7030 1052207030
105220-7030 SUPPLY PUMP
Rating:
49
Buy SUPPLY PUMP 105220-7030 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152062-0020 PUMP HOUSING
2. [1] 152030-0200 STOP PIN
5. [1] 152100-2301 PUMP PLUNGER
6. [1] 152102-0400 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 139526-0000 GASKET
14. [2] 152115-0500 VALVE BODY
14. [2] 152115-0500 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
17. [1] 152118-0900 ADAPTOR
18. [2] 029631-6060 O-RING
18. [2] 029631-6060 O-RING
25. [1] 152200-6720 HAND PRIMER
30. [1] 152300-5520 EYE BOLT
32. [1] 029731-4680 EYE BOLT
35. [2] 026514-1840 GASKET D17.9&14.2T1
36. [2] 026514-1840 GASKET D17.9&14.2T1

Cross reference number

Zexel num
Bosch num
Firm num
Name
105220-7030 
9 441 610 220 
NP-FP/KSP-A 
   
SUPPLY PUMP
K 14GC FEED PUMP F/P




Information:

Storage Procedure
When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters. Refer to step 2 belowIf a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To Remove Moisture
To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.

Have questions with 105220-7030?





Group cross 105220-7030 ZEXEL

 
 

Nissan-Diesel 

9 441 610 239 
NP-FP/KSP-AD 
16640Z5569 
SUPPLY PUMP

Nissan 

9 441 610 240 
NP-FP/KSP-A 
16640Z5568 
SUPPLY PUMP

Nissan-Diesel 

9 441 610 240 
NP-FP/KSP-A 
16640Z5568 
SUPPLY PUMP
105220-7030  
9 441 610 220 
NP-FP/KSP-A 
 
SUPPLY PUMP

Yanmar 

9 441 610 266 
NP-FP/KSP-AD 
12760552100 
SUPPLY PUMP

Nissan-Diesel 

9 441 610 188 
NP-FP/KSP-A 
16640Z5571 
SUPPLY PUMP
9 441 610 202 
NP-FP/KSP-AD 
1664095008 
SUPPLY PUMP
9 441 610 565 
NP-FP/KSP-A 
 
SUPPLY PUMP
F 01G 19U 001 
NP-FP/KSP-A 
 
SUPPLY PUMP
9 441 610 221 
NP-FP/KSP-AD 
 
SUPPLY PUMP
Back to top