105217-6100 ZEXEL 9 440 610 526 BOSCH SUPPLY PUMP 9440610526 1052176100


 

Information supply pump

BOSCH 9 440 610 526 9440610526
ZEXEL 105217-6100 1052176100
105217-6100 SUPPLY PUMP
Rating:
59
Buy SUPPLY PUMP 105217-6100 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152061-0020 PUMP HOUSING
2. [1] 152030-0000 STOP PIN
5. [1] 152100-2301 PUMP PLUNGER
6. [1] 152102-1600 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 139526-0000 GASKET
14. [2] 152115-0500 VALVE BODY
14. [2] 152115-0500 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
16. [1] 152117-0620 CAPSULE
18. [2] 139716-0000 O-RING
18. [2] 139716-0000 O-RING
25. [1] 152200-6721 HAND PRIMER
30. [1] 152300-5920 EYE BOLT
32. [1] 029731-4680 EYE BOLT
35. [2] 029341-4130 GASKET D20&13.8T2*
36. [2] 029341-4130 GASKET D20&13.8T2*
42. [1] 152320-0100 COVER

Include in #1:

106692-9270 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105217-6100 
9 440 610 526 
NP-FP/KEP-P 
   
SUPPLY PUMP
K 14GC FEED PUMP F/P




Information:


Image1.1.1
5. Attach a hose to the other end of the fuel rail and hold the free end of the hose in a cup/bucket of water. Hose shown is a JIC 37o ?6 hose. Refer to Illustration 1.2.1
Image1.2.1
6. Pressurize the cooling system with compressed air and regulate pressure between 5-15 psi.
Do Not Exceed 15 psi or Cooling System Damage Can Result.
7. Submerse the hose in a cup/bucket of water.
8. Monitor for 10 minutes and check for a steady rate of air bubbles coming out of the hose that is submersed in the cup/bucket of water.
9. If steady stream of air is present, replace the cylinder head, coolant regulators, and both 030-7937 port connectors. Depending on the application, you will need to replace some cooling system seals. (List of seals by application to be included)
10. Once the cylinder heads have been replaced pressure test the head again using the same procedure. Once this has been completed the cooling system should be flushed using instructions listed below.
Cleaning the Cooling System
1. Drain all of the coolant form cooling system.
2. Fill the cooling system with clean water.
3. Start engine and run it until the thermostat opens.
4. Add two cups of non-foaming liquid automatic dish washer soap.
Note: Do not use plain dish soap. Aeration of the cooling system and resultant damage could occur.
5. After the soap has bee added run engine for approximately twenty minutes. Check to see if the fuel is breaking up.
6. If the fuel is still not breaking up than add two more cups of soap and run for 10 minutes. Drain mixture from cooling system.
7. Fill cooling system with clean water and check surface for fuel. If fuel is present, repeat steps 3 through 7. When water is clear, drain and rinse the cooling system one more time. Then add coolant and conditioner.

Have questions with 105217-6100?





Group cross 105217-6100 ZEXEL

105217-6100  
9 440 610 526 
NP-FP/KEP-P 
 
SUPPLY PUMP
9 440 610 169 
NP-FP/KEP-P 
 
SUPPLY PUMP

Mitsubishi 

9 440 610 892 
NP-FP/KEP-P 
ME740844 
SUPPLY PUMP

Hino 

9 440 610 224 
NP-FP/KEP-P 
225602440A 
SUPPLY PUMP
 
 

Mitsubishi 

9 440 610 629 
NP-FP/KEP-P 
ME748433 
SUPPLY PUMP
9 440 610 504 
NP-FP/KEP-P 
 
SUPPLY PUMP
Back to top