105217-0000 ZEXEL 9 440 610 607 BOSCH SUPPLY PUMP 9440610607 1052170000 me742786


 

Information supply pump

BOSCH 9 440 610 607 9440610607
ZEXEL 105217-0000 1052170000
MITSUBISHI ME742786 me742786
105217-0000 SUPPLY PUMP
Rating:
49
Buy SUPPLY PUMP 105217-0000 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152000-4620 PUMP HOUSING
5. [1] 152100-1120 PUMP PLUNGER
6. [1] 152102-0400 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 029332-6030 GASKET
10. [1] 152111-3221 TAPPET
10/2. [1] 152112-0500 ROLLER
10/3. [1] 152113-1000 BEARING PIN
10/4. [2] 152114-1600 SLIDER
14. [2] 152115-0200 VALVE BODY
14. [2] 152115-0200 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
16. [1] 152117-0400 CAPSULE
18. [2] 029331-6030 GASKET
18. [2] 029331-6030 GASKET
20. [1] 152121-0200 LOCKING WASHER
25. [1] 152117-0400 CAPSULE
30. [1] 152300-7120 EYE BOLT
32. [1] 029731-4570 EYE BOLT
35. [2] 029341-4130 GASKET D20&13.8T2*
36. [2] 029341-4130 GASKET D20&13.8T2*

Include in #1:

106673-7940 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105217-0000 
9 440 610 607 
NP-FP/KE-P 
ME742786  MITSUBISHI
SUPPLY PUMP
K 14GC FEED PUMP F/P




Information:

Starting System
Use a D.C. voltmeter to locate starting system components which do not function.Move starting control switch to energize the starter solenoid. Starter solenoid operation is audible as the starter motor pinion engages with the ring gear on the engine flywheel. The solenoid operation should also close the electric circuit to the motor. Attach one voltmeter lead to the solenoid terminal that is connected to the motor. Ground the other lead. Energize the starter solenoid and observe the voltmeter. A battery voltage reading indicates the malfunction is in the motor. It must be removed for further testing. No voltmeter reading indicates that the solenoid contacts do not close and the solenoid must be repaired or the starter pinion clearance should be adjusted.A starting motor solenoid that will not operate may not be receiving battery current. Attach one lead of the voltmeter to the solenoid battery cable connection. Ground the other lead. No voltmeter reading indicates a faulty circuit from the battery. A voltmeter reading indicates further testing is necessary.Continue the test by attaching one voltmeter lead to the starting motor solenoid small wire terminal and the other lead to ground. Observe the voltmeter and energize the starter solenoid. A voltmeter reading indicates that the malfunction is in the solenoid. No voltmeter reading indicates the starter switch or wiring is the fault.Attach one lead of the voltmeter to the starter switch battery wire terminal and ground the other lead. A voltmeter reading indicates a defective switch.A starting motor that operates too slow can be overloaded by excessive mechanical friction within the engine being started. Slow starting motor operation can also be caused by shorts, loose connections and/or excessive dirt within the motor.Pinion Clearance Adjustment (Prestolite)
There are two adjustments on this type motor. Armature end play and pinion position.Armature End Play
Adjust the end play to .005 to .030 in. (0.13 to 0.76 mm) by adding or removing thrust washers on the commutator end of the armature shaft.Pinion Position
This adjustment is accomplished in two steps.1. To adjust the pinion distance, connect the solenoid to a 12 volt battery as shown.Momentarily flash the jumper lead from the motor terminal stud of the solenoid to the terminal stud at (1) in the commutator end head to shift the solenoid and drive into the cranking position.
CONNECTIONS FOR ADJUSTING THE PINION POSITION
1. Jumper lead flashing point.Remove the jumper lead. The drive will remain in the cranking position until the battery is disconnected.Push the drive toward the commutator end of the motor to eliminate any slack movement in the linkage and measure the distance between the outside edge of the drive sleeve and the thrust washer. The distance (3) must be .02 to .05 in. (0.5 to 1.3 mm).Adjust to this dimension by turning the adjusting nut (2) in or out as required.
PINION POSITION ADJUSTMENT
2. Adjusting nut. 3. Distance.2. To test assembly of solenoid, it will be necessary to have an interference block cut to the dimensions shown.
INTERFERENCE BLOCK DIMENSIONSConnect the solenoid to 24 volts as

Have questions with 105217-0000?





Group cross 105217-0000 ZEXEL

Mitsubishi 

105217-0000  
9 440 610 607 
NP-FP/KE-P 
ME742786 
SUPPLY PUMP
Back to top