105210-5350 ZEXEL 9 440 610 492 BOSCH SUPPLY PUMP 9440610492 1052105350 8970832620


 

Information supply pump

BOSCH 9 440 610 492 9440610492
ZEXEL 105210-5350 1052105350
ISUZU 8970832620 8970832620
105210-5350 SUPPLY PUMP
Rating:
45
Buy SUPPLY PUMP 105210-5350 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152051-0920 PUMP HOUSING
5. [1] 152100-1120 PUMP PLUNGER
6. [1] 152102-0400 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 139526-0000 GASKET
10. [1] 152111-2820 TAPPET
10/2. [1] 152112-0100 ROLLER
10/3. [1] 152113-0700 BEARING PIN
10/4. [2] 152114-0400 SLIDER
14. [2] 152115-0500 VALVE BODY
14. [2] 152115-0500 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
16. [1] 152118-0900 ADAPTOR
18. [1] 029631-6060 O-RING
19. [1] 029631-6060 O-RING
20. [1] 152121-0200 LOCKING WASHER
25. [1] 152200-6720 HAND PRIMER
30. [1] 152300-5520 EYE BOLT
32. [1] 029111-4050 CAPSULE
33. [1] 152350-7920 PIPE
35. [2] 139514-0000 GASKET D19.2&14.2T1.0
36. [2] 139514-0000 GASKET D19.2&14.2T1.0
49. [1] 139814-0000 EYE BOLT
51. [1] 026514-2040 GASKET

Include in #1:

101401-4290 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105210-5350 
9 440 610 492 
8970832620  ISUZU
SUPPLY PUMP
* K




Information:


Fig. 32-In-Circuit Negative Rectifier Diode Test PointsTo check negative diode assembly, connect tester to diode plate stud (1, Fig. 32) and to diode lead (2). Check remaining diodes (3 and 4) by the same method.
Fig. 33-In-Circuit Positive Rectifier Diode Test PointsTo check positive diode assembly, connect tester to output terminal (1, Fig. 33) and to diode lead (2). Check remaining diodes (3 and 4) by the same method.In-Circuit Rectifier Diode Test With Test Light
IMPORTANT: Do not use a 120-volt test lamp. Use a 12-volt DC test lamp only; otherwise diodes will be damaged.
Fig. 34-In-Circuit Negative Rectifier Diode Test PointsTo check negative diode assembly, connect test lamp probes to diode plate stud (1, Fig. 34) and to diode lead (2). Reverse test lamp probes. Test lamp should light in one direction only.Recheck diodes individually after disassembly to determine which diode is shorted if test lamp lights in both directions.
Fig. 35-In-Circuit Positive Rectified Diode Test PointsTo check positive diode assembly, connect test lamp probes to output terminal (1, Fig. 35) and to diode lead (2). Reverse test lamp probes. Test lamp should light in one direction only.Recheck diodes individually after disassembly to determine which diode is shorted if test lamp lights in both directions.Field Leakage (Short) Test
Remove the regulator and brush assembly.
Fig. 36-Field Leakage Test PointsConnect ohmmeter or test lamp (12 volt or 120 volt may be used) test probes to one of the slip rings (1, Fig. 36) and to the ground terminal (2).Ohmmeter resistance should be infinite (test lamp should not light).Repeat test after rotor has been removed to ascertain leakage or short. Connect test probes to one of the slip rings and to rotor shaft.In-Circuit Stator Leakage (Short) Test
IMPORTANT: Do not use a 120-volt test lamp. Use a 12-volt DC test lamp only, otherwise diodes will be damaged.
Fig. 37-In-Circuit Stator Leakage Test PointsTo check stator leakage, connect test lamp probes to diode plate (1, Fig. 37) and to diode lead 2. Reverse test lamp probes. Test lamp should light in one direction only.Repeat test after stator has been removed if test light lights in both directions.Out-of-Circuit Stator Leakage (Short) Test
Remove rectifier diode plates and stator as an assembly.
Fig. 38-Out-of-Circuit Stator Leakage Test PointsConnect ohmmeter or test lamp (12 volt only) probes to a diode lead (1, Fig. 38) and to the stator (2).Resistance reading should be infinite (test lamp should not light).Stator
Disconnect the stator leads from the diode leads.
Fig. 39-Grounded Stator Winding Test PointsCheck for a grounded winding by connecting ohmmeter probes to one stator lead (1, Fig. 39) and to the stator frame (2). The ohmmeter reading should be infinite.
Fig. 40-Shorted Stator Winding Test PointsUsing a sensitive ohmmeter which has been carefully zeroed, connect probes to lead (1, Fig. 40) and to lead (2). Resistance should be 0.4 ohm. If the reading is infinite replace stator.With the ohmmeter probes on (1) and (2) touch leads (3) and (4) together. Resistance should be 0 ohm. If resistance is not 0 ohm, replace stator.Repeat test on leads (1)

Have questions with 105210-5350?





Group cross 105210-5350 ZEXEL

 
 

Mitsubishi 

9 440 610 553 
NP-FP/KE-AS 
ME730808 
SUPPLY PUMP

Mazda 

9 440 610 401 
TM0113VF0 
SUPPLY PUMP

Isuzu 

9 440 610 427 
8970811820 
SUPPLY PUMP
9 440 610 491 
8970811810 
SUPPLY PUMP
105210-5350  
9 440 610 492 
8970832620 
SUPPLY PUMP
9 440 610 544 
8970851480 
SUPPLY PUMP
9 440 610 428 
8970942250 
SUPPLY PUMP
9 440 610 178 
NP-FP/KE-AD 
 
SUPPLY PUMP

Isuzu 

9 440 610 962 
8970894430 
SUPPLY PUMP
9 440 610 429 
8970937610 
SUPPLY PUMP
9 440 610 583 
NP-FP/KE-A 
 
SUPPLY PUMP
Back to top