105210-4180 ZEXEL 9 440 610 686 BOSCH SUPPLY PUMP 9440610686 1052104180 225601170a


 

Information supply pump

BOSCH 9 440 610 686 9440610686
ZEXEL 105210-4180 1052104180
HINO 225601170A 225601170a
105210-4180 SUPPLY PUMP
Rating:
9
Buy SUPPLY PUMP 105210-4180 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152000-3620 PUMP HOUSING
5. [1] 152100-1120 PUMP PLUNGER
6. [1] 152102-1500 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 029332-6030 GASKET
10. [1] 152111-2820 TAPPET
10/2. [1] 152112-0100 ROLLER
10/3. [1] 152113-0700 BEARING PIN
10/4. [2] 152114-0400 SLIDER
14. [2] 152115-0100 VALVE BODY
14. [2] 152115-0100 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
16. [1] 152117-0100 CAPSULE
18. [2] 029331-6030 GASKET
18. [2] 029331-6030 GASKET
20. [1] 152121-0200 LOCKING WASHER
25. [1] 152200-1220 HAND PRIMER
30. [1] 152300-3020 EYE BOLT
32. [1] 029731-4080 EYE BOLT
35. [2] 139514-0300 GASKET
36. [2] 139514-0300 GASKET
42. [1] 152320-0100 COVER
47. [1] 152325-0100 EYE BOLT
48. [2] 029331-6040 GASKET

Include in #1:

101693-2560 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105210-4180 
9 440 610 686 
NP-FP/KE-A 
225601170A  HINO
SUPPLY PUMP
K 14GC FEED PUMP F/P




Information:

Precautions for Electrical System
* Before working on the electrical system, disconnect the (-) battery cable to prevent short circuits.
* Make sure the electrical equipment is OFF before disconnecting or connecting battery cable. Semiconductor components may otherwise be damaged.
* Carefully handle sensors relays, and other items that are sensitive to shock and heat. * When applying a voltage to a part for inspection purposes, check that the (+) and (-) cables are connected properly then gradually increase the voltage from zero. Do not exceed the specified voltage. Remember that sensors do not necessarily operate on the battery voltage. * When separating connectors, grasp the connectors themselves rather than the harnesses. * To separate locking connectors, first push them in the direction of the arrows. To reconnect locking connectors, push them together until they click.* Before washing the parts, cover electrical parts to keep them dry. (Use plastic sheets or the like.) Keep water away from harness connectors and sensors and immediately wipe off any water that gets on them. Handling precautions for electric circuits
* Do not pierce wire insulation with test probes or alligator clips when performing electrical inspections. Doing so can, particularly with the chassis harness, hasten corrosion.
(1) Inspection of harnesses (1.1) Inspections with connectors fitted together* Waterproof connectors* Connect an inspection harness and connector. A between the connectors B of the circuit to be inspected. Perform the inspection by applying a test probe C to the connectors of the inspection harness. Do not insert the test probe C into the wire-entry sides of the waterproof connectors since this would damage their waterproof seals and lead to rust. * Non-waterproof connectors* Perform the inspection by inserting a test probe C into the wire-entry sides of the connectors. An extra-narrow probe is required for control unit connectors, which are smaller than other types of connector. Do not force a regular-size probe into control unit connectors since this would cause damage. (1.2) Inspections with connectors separated* Inspections on female terminals* Perform the inspection by carefully inserting a test probe into the terminals. Do not force the test probe into the terminals since this could deform them and cause poor connections. * Inspections on male terminals* Perform the inspection by applying test probes directly to the pins.
* Be careful not to short-circuit pins together with the test probes. With control unit connectors, short-circuiting of pins can cause damage to the control unit's internal circuitry.
* When using a multimeter to check continuity, do not allow the test probes to touch the wrong terminals. (2) Inspection of connectors (2.1) Visual inspection* Check that the connectors are fitted together securely. * Check whether wires have been separated from their terminals due to pulling of the harness. * Check that male and female terminals fit together tightly. * Check for defective connections caused by loose terminals, by rust on terminals, or by contamination of terminals by foreign substances. (2.2) Checking for loose terminals* If connector terminal retainers become damaged, male and female terminals may not

Have questions with 105210-4180?





Group cross 105210-4180 ZEXEL

 
 

9 440 610 422 
 
SUPPLY PUMP
 
 
SUPPLY PUMP

Mitsubishi 

9 440 610 683 
NP-FP/KE-AD 
3126156800 
SUPPLY PUMP
9 440 610 683 
NP-FP/KE-AD 
ME059524 
SUPPLY PUMP
9 440 610 684 
NP-FP/KE-AD 
3196148400 
SUPPLY PUMP
 
3006129031 
SUPPLY PUMP
9 440 610 028 
NP-FP/KE-ADS 
ME056098 
SUPPLY PUMP

Mitsubishi-Heav 

9 440 610 028 
NP-FP/KE-ADS 
3096100700 
SUPPLY PUMP
9 440 610 028 
NP-FP/KE-ADS 
3126170300 
SUPPLY PUMP

Mitsubishi 

9 440 610 024 
NP-FP/KE-ADS 
ME730589 
SUPPLY PUMP

Hino 

9 440 611 010 
225601040A 
SUPPLY PUMP
9 440 611 010 
225601070A 
SUPPLY PUMP
9 440 610 058 
NP-FP/KE-A 
225601041A 
SUPPLY PUMP

Mitsubishi 

9 440 610 685 
NP-FP/KE-ADS 
3096101200 
SUPPLY PUMP
9 440 610 685 
NP-FP/KE-ADS 
ME056099 
SUPPLY PUMP

Hino 

105210-4180  
9 440 610 686 
NP-FP/KE-A 
225601170A 
SUPPLY PUMP
Back to top