105207-1580 ZEXEL 9 440 610 572 BOSCH SUPPLY PUMP 9440610572 1052071580


 

Information supply pump

BOSCH 9 440 610 572 9440610572
ZEXEL 105207-1580 1052071580
105207-1580 SUPPLY PUMP
Rating:
8
Buy SUPPLY PUMP 105207-1580 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152051-1820 PUMP HOUSING
5. [1] 152100-1120 PUMP PLUNGER
6. [1] 152102-2100 COMPRESSION SPRING
7. [1] 152105-1500 CAPSULE
8. [1] 029332-6030 GASKET
10. [1] 152111-3221 TAPPET
10/2. [1] 152112-0500 ROLLER
10/3. [1] 152113-1000 BEARING PIN
10/4. [2] 152114-1600 SLIDER
14. [2] 152115-0500 VALVE BODY
14. [2] 152115-0500 VALVE BODY
15. [2] 152116-0200 COILED SPRING
15. [2] 152116-0200 COILED SPRING
17. [1] 152118-1700 ADAPTOR
18. [1] 029631-6060 O-RING
19. [1] 029631-6060 O-RING
20. [1] 152121-0200 LOCKING WASHER
25. [1] 152200-5420 HAND PRIMER
30. [1] 152300-7120 EYE BOLT
32. [1] 029111-4050 CAPSULE
35. [2] 029341-4130 GASKET D20&13.8T2*
36. [1] 026514-1840 GASKET
49. [1] 029731-4680 EYE BOLT
51. [2] 029341-4130 GASKET D20&13.8T2*

Include in #1:

106871-9120 as SUPPLY PUMP

Cross reference number

Zexel num
Bosch num
Firm num
Name
105207-1580 
9 440 610 572 
NP-FP/K-P 
   
SUPPLY PUMP
K




Information:

Condition: DEF nozzle does not shut off, causing DEF to exit the tank breather
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at a downward angle may cause DEF to exit breather before the float in the tank valve rises enough to shut off nozzle.
Verify that the pressure at the nozzle from supply pump meets minimum 172 to 200 kPa (25 to 29 psi) requirement to trigger nozzle shut off.
Inspect tank-mounted valve for debris or ice preventing closure.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Replace or repair as needed.Condition: DEF Nozzle shuts off before tank is full
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at an upward angle may cause DEF Nozzle to shut off prematurely because DEF level at the rear of the tank near valve may cause float to rise and shut off nozzle.
Verify that flow at nozzle does not exceed the recommended target of 45 L/min (12 US gpm).
Excessive flow can damage tank-mounted valve and cause premature shut off.
Inspect vent line going up to breather and breather for any blockage, clean or replace if needed.
Inspect DEF fast fill line from receiver to valve, the valve for any blockages. Clean or replace if needed.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Repair or replace as needed.

Have questions with 105207-1580?





Group cross 105207-1580 ZEXEL

Hino 

9 440 610 214 
NP-FP/K-P 
225602180A 
SUPPLY PUMP
 
 

9 440 610 579 
NP-FP/K-PS 
 
SUPPLY PUMP
9 440 610 707 
NP-FP/K-PS 
 
SUPPLY PUMP
9 440 610 580 
NP-FP/K-PS 
 
SUPPLY PUMP
9 440 610 969 
NP-FP/K-P 
 
SUPPLY PUMP
9 440 610 581 
NP-FP/K-P 
 
SUPPLY PUMP
9 440 610 175 
NP-FP/K-P 
 
SUPPLY PUMP
105207-1580  
9 440 610 572 
NP-FP/K-P 
 
SUPPLY PUMP
 
 

Back to top