Information supply pump
BOSCH
9 440 610 397
9440610397
ZEXEL
105207-1250
1052071250
MITSUBISHI
ME717159
me717159

Rating:
Scheme ###:
1. | [1] | 152000-4620 | PUMP HOUSING |
5. | [1] | 152100-1120 | PUMP PLUNGER |
6. | [1] | 152102-0400 | COMPRESSION SPRING |
7. | [1] | 152105-1500 | CAPSULE |
8. | [1] | 029332-6030 | GASKET |
10. | [1] | 152111-3221 | TAPPET |
10/2. | [1] | 152112-0500 | ROLLER |
10/3. | [1] | 152113-1000 | BEARING PIN |
10/4. | [2] | 152114-1600 | SLIDER |
14. | [2] | 152115-0200 | VALVE BODY |
14. | [2] | 152115-0200 | VALVE BODY |
15. | [2] | 152116-0200 | COILED SPRING |
15. | [2] | 152116-0200 | COILED SPRING |
16. | [1] | 152117-0400 | CAPSULE |
18. | [1] | 029331-6030 | GASKET |
20. | [1] | 152121-0200 | LOCKING WASHER |
25. | [1] | 152200-5420 | HAND PRIMER |
26. | [1] | 152207-1800 | ADAPTOR |
27. | [1] | 029631-6060 | O-RING |
30. | [1] | 152300-7120 | EYE BOLT |
32. | [1] | 029731-4570 | EYE BOLT |
35. | [2] | 029341-4130 | GASKET D20&13.8T2* |
36. | [2] | 029341-4130 | GASKET D20&13.8T2* |
47. | [1] | 152325-0100 | EYE BOLT |
48. | [2] | 029331-6040 | GASKET |
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Note: The standard work for the laser mark has been updated.Problem
Illustration 1 g06273667During laser marking on these Reman 3400 HEUI injectors both Prime and Non-Prime injectors were marked with NP. This caused confusion with dealers and customers. The NP is thought to mean "Non-Prime" and the injectors are Prime injector part numbers. The prime injectors marked incorrectly with NP but were built and tested to the correct Prime part number and should be used in fuel systems for prime injectors. Dealers can remove the two letters if they decide the two letters cause too much confusion.Solution
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Illustration 2 g06273668
Prime HEUI injector
NP stands for "Non-Prime". Going forward only "Non-Prime" 3400 HEUI injectors will have the NP laser mark.
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Note: The standard work for the laser mark has been updated.Problem
Illustration 1 g06273667During laser marking on these Reman 3400 HEUI injectors both Prime and Non-Prime injectors were marked with NP. This caused confusion with dealers and customers. The NP is thought to mean "Non-Prime" and the injectors are Prime injector part numbers. The prime injectors marked incorrectly with NP but were built and tested to the correct Prime part number and should be used in fuel systems for prime injectors. Dealers can remove the two letters if they decide the two letters cause too much confusion.Solution
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Illustration 2 g06273668
Prime HEUI injector
NP stands for "Non-Prime". Going forward only "Non-Prime" 3400 HEUI injectors will have the NP laser mark.