150560-1500 ZEXEL 9 431 610 691 BOSCH SLOTTED WASHER 9431610691 1505601500 1153420040


 

Information slotted washer

BOSCH 9 431 610 691 9431610691
ZEXEL 150560-1500 1505601500
ISUZU 1153420040 1153420040
150560-1500 SLOTTED WASHER
Rating:
59
Buy SLOTTED WASHER 150560-1500 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 4
SLOTTED WASHER
1050482081 as SLOTTED WASHER

Cross reference number

Zexel num
Bosch num
Firm num
Name
150560-1500 
9 431 610 691 
1153420040  ISUZU
SLOTTED WASHER
C 53PZ SPRING SEAT NH parts NH
150560-1500 
9 431 610 691 
62153420060  ISEKI
SLOTTED WASHER
C 53PZ SPRING SEAT NH parts NH
150560-1500 
9 431 610 691 
2286322408  FUJI-HEAVY
SLOTTED WASHER
C 53PZ SPRING SEAT NH parts NH
150560-1500 
9 431 610 691 
16416ZG30030  HONDA
SLOTTED WASHER
C 53PZ SPRING SEAT NH parts NH




Information:

Appendix
Configuration Information
Table 7
Over-Temp    
Inlet Over-Temperature Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output function     ON only during alarm    
    Assert Alarm     Above
650 °C (1202 °F)    
    Hysteresis    
20 °C (68 °F)    
    Upon Over Temperature extend alarm for 60 seconds    
Table 8
Over-Pres    
Over-Pressure Warning        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     ON only during alarm    
    Assert Alarm when the measured pressure exceeds 7" of Hg for 5% of the time during a 60 min measurement interval    
Over-Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 2    
    Output Function     Latched ON upon alarm    
    Assert alarm when the measured pressure exceeds 8" of Hg for 5% of the time during a 60 min measurement interval    
Table 9
TC-Fail (1)    
Open Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if measured temperature is above
1000 °C (1832 °F)    
Shorted Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if pressure is greater than 1" of Hg for 10 min and measured temperature does not exceed
120 °C (248 °F)    
( 1 ) Output selection applies to both open and shorted alarms
Table 10
Pressure Sensor Fail    
No Change Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Outputs During Alarm     Output 1    
    Output Function     Latched ON upon Alarm    
    Assert alarm if exhaust temperature is above
250 °C (482 °F) for 10 min and the pressure doesn't change by at least 0.25" of Hg    
Negative Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     Latched ON during alarm    
    Assert Alarm if temperature is above
200 °C (392 °F) for 10 min and the pressure is less than −1" of

Have questions with 150560-1500?





Group cross 150560-1500 ZEXEL

Isuzu 

150560-1500  
9 431 610 691 
1153420040 
SLOTTED WASHER

Iseki 

150560-1500  
9 431 610 691 
62153420060 
SLOTTED WASHER

Fuji-Heavy 

150560-1500  
9 431 610 691 
2286322408 
SLOTTED WASHER

Honda 

150560-1500  
9 431 610 691 
16416ZG30030 
SLOTTED WASHER
Back to top