150534-2300 ZEXEL 9 431 610 227 BOSCH SHIM 9431610227 1505342300 8941769580


 

Information shim

BOSCH 9 431 610 227 9431610227
ZEXEL 150534-2300 1505342300
ISUZU 8941769580 8941769580
150534-2300 SHIM
Rating:
56
Buy SHIM 150534-2300 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 12/1
SHIM  
T1.73
1050780300 as SHIM T1.73

Cross reference number

Zexel num
Bosch num
Firm num
Name
150534-2300 
9 431 610 227 
8941769580  ISUZU
SHIM
C 53PZ SHIM NH parts NH
150534-2300 
9 431 610 227 
1661389TJ2  NISSAN
SHIM
C 53PZ SHIM NH parts NH




Information:

17. Add coolant mixture if necessary to bring the coolant to within 13 mm (1/2 inch) below the bottom of the fill tube or the correct level on the sight glass, if equipped. Upon initial fill the sight gauge can indicate an incorrect coolant level. Be sure the coolant is to the bottom of the fill tube. Recheck the coolant level and fill the cooling system to the bottom of the fill tube if the system was low.
In cold weather, frequently check the specific gravity of the coolant solution to ensure adequate protection.If the engine is to be stored in, or shipped to an area with freezing temperatures, the cooling system must be either protected to the lowest expected outside temperature or drained completely to prevent damage. Always check your cooling system before operating your engine. Depending on load, failure to operate with thermostats could result in either an overheating or an excessive cooling condition.
18. Check the condition of the filler cap gasket (if equipped). If the gasket is damaged, discard the old filler cap and install a new filler cap. 19. Stop the engine and check the coolant to ensure it is at the proper level. Every 10,000 Hour Cleaning Procedure-Oil Cooler and Aftercooler Core
Caterpillar recommends that the oil cooler and aftercooler cores be removed, cleaned and pressure tested at Every 10,000 Hour overhaul time, or if a turbocharger failure has occurred, or if at any time the turbocharger develops an oil leak.1. Remove the core. Turn the core upside down to remove debris from the inlet.
Do not use caustic cleaners to clean the core. Caustic cleaners will attack the internal metals of the core and cause leakage.
2. Back flush internally with a solvent to loosen foreign substances and to remove oil. Caterpillar recommends the use of Caterpillar Hydrosolv 4165 or Hydrosolv 100 Liquid Cleaners. 3. Shake the core vigorously to eliminate any trapped debris. 4. Wash the core with hot, soapy water. Rinse thoroughly with clean water. 5. Dry the core with compressed air. Blow air in reverse direction of normal flow. Use all necessary safety equipment while using compressed air. 6. Inspect the system to ensure cleanliness and install the core. SR4 Generator
Make sure residual voltage in the rotor, stator and the generator is discharged.If this generator is to be connected to a utility electrical distribution system, it must be isolated from the distribution system by means of:a. Opening the main switch in the case of the generator temporarily connected to the system or,b. A double throw (transfer) switch in the case of a permanent connection to the system.Failure to do so could result in personal injury or death due to electrical shock. This warning does not apply when a generator and utility distribution system are designed and approved by the utility to run in parallel.
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.Electronic components in the regulator can be damaged during generator

Have questions with 150534-2300?





Group cross 150534-2300 ZEXEL

Isuzu 

150534-2300  
9 431 610 227 
8941769580 
SHIM

Nissan 

150534-2300  
9 431 610 227 
1661389TJ2 
SHIM
Back to top