150532-2200 ZEXEL 9 431 610 423 BOSCH SHIM 9431610423 1505322200 1153390640


 

Information shim

BOSCH 9 431 610 423 9431610423
ZEXEL 150532-2200 1505322200
ISUZU 1153390640 1153390640
150532-2200 SHIM
Rating:
55
Buy SHIM 150532-2200 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 9/1
SHIM  
D11.5&4.5T1.23
1050304140 as SHIM D11.5&4.5T1.23

Cross reference number

Zexel num
Bosch num
Firm num
Name
150532-2200 
9 431 610 423 
1153390640  ISUZU
SHIM
C 53PZ SHIM NH parts NH
150532-2200 
9 431 610 423 
ME722081  MITSUBISHI
SHIM
C 53PZ SHIM NH parts NH




Information:

Prior to stopping an engine that is being operated at low loads, run the engine at low idle for 30 seconds before stopping. But, if the engine is being operated at highway speeds and/or high loads, then it should be run at low idle for three minutes to reduce and stabilize internal engine temperature before stopping.To stop the engine, use the method listed that applies to the shutoff system on your truck.1. Turn the key switch to the OFF position, or2. ... pull OUT the manual shutoff control (if equipped), or3. ... push IN and hold the stop button until the engine stops, then release the button.Make sure the shutoff procedure is understood. Refer to the truck manufacturer's instructions for your type of engine shutoff system used. Fill the fuel tank at the end of each day of operation to drive out moist air and to prevent condensation. Do not fill the tank to the top. Fuel expands as it gets warm and may overflow.Manual Fuel Shutoff Lever
A manual shutdown lever is provided to override the governor control of the engine. The manual shutoff solenoid override lever is located on the side of the fuel pump. This shutdown will only move the fuel control linkage to the FUEL-OFF position. It does not shut off the air inlet. Shutoff Solenoid Override
The manual shutoff solenoid override lever is located on the side of the electronic governor. The engine can be shut OFF by rotating and holding the manual shutoff lever in the counterclockwise (CCW) direction. Rotating and holding the manual shutoff lever in the clockwise (CW) direction overrides the shutoff solenoid. The lever is spring loaded and will return to the neutral position when released.If the solenoid has been disabled, the engine cannot be shut OFF from inside the cab. The engine can be shut OFF by using the manual shutoff lever as an emergency shutoff lever.
DO NOT operate the engine without the rack actuator solenoid (BTM) in place and with the fuel shutoff solenoid disabled. Excessive engine speed (overspeed) may result.

Have questions with 150532-2200?





Group cross 150532-2200 ZEXEL

Isuzu 

150532-2200  
9 431 610 423 
1153390640 
SHIM

Mitsubishi 

150532-2200  
9 431 610 423 
ME722081 
SHIM
Back to top