Information shim
BOSCH
9 461 610 229
9461610229
ZEXEL
146420-5200
1464205200
ISUZU
8941116590
8941116590

Rating:
Include in ###:
Number on scheme 52/1
1047000500
as SHIM
D9.5&3.0T1.76
1047009153
as SHIM
1047009154
as SHIM
D9.5&3.0T1.76
Cross reference number
Zexel num
Bosch num
Firm num
Name
146420-5200
9 461 610 229
8941116590 ISUZU
SHIM
C 11FV SHIM parts(VE) Others
C 11FV SHIM parts(VE) Others
146420-5200
9 461 610 229
ME741122 MITSUBISHI
SHIM
C 11FV SHIM parts(VE) Others
C 11FV SHIM parts(VE) Others
146420-5200
9 461 610 229
168845C909 NISSAN
SHIM
C 11FV SHIM parts(VE) Others
C 11FV SHIM parts(VE) Others
146420-5200
9 461 610 229
168845C909 NISSAN-DIESEL
SHIM
A C 11FV SHIM parts(VE) Others
A C 11FV SHIM parts(VE) Others
146420-5200
9 461 610 229
RFS113V95 MAZDA
SHIM
C 11FV SHIM parts(VE) Others
C 11FV SHIM parts(VE) Others
Information:
Illustration 1 g00565418
4W-8471 Time Delay Relay
Use a 6V-7070 Digital Multimeter, a stopwatch, and a battery (8 volts to 40 volts) for this test.
Connect the positive lead of the voltage source to terminal (TD-4) of the time delay relay. Connect the negative lead to terminal (TD-3). If the test is done on an engine, the start/stop switch must be in the STOP position in order to power terminal (TD-6). All connections must be maintained until the tests are completed.
Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 1
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Connect the positive lead of the voltage source to terminal (TD-1). If the time delay relay is tested on the engine do not leave the voltage source hooked to terminal (TD-1) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 2
Terminals     Relay Position    
5-6     Open    
6-7     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 3
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    Note: If a jumper is normally installed across terminals (TD-2) and (TD-3), the jumper must be removed before performing Step 5.
Connect the positive lead of the voltage source to terminal (TD-2). If the time delay relay is tested on the engine, do not leave the voltage source on terminal (TD-2) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 4
Terminals     Delay Time of Relay Position    
0 to 8 seconds 10 seconds or more    
5-6     Closed     Open    
6-7     Open     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 5
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    
Remove the voltage source from terminal (TD-4). Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 6
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Have questions with 146420-5200?
Group cross 146420-5200 ZEXEL
Isuzu
146420-5200
9 461 610 229
8941116590
SHIM
Mitsubishi
146420-5200
9 461 610 229
ME741122
SHIM
Nissan
146420-5200
9 461 610 229
168845C909
SHIM
Nissan-Diesel
146420-5200
9 461 610 229
168845C909
SHIM
Mazda
146420-5200
9 461 610 229
RFS113V95
SHIM