146420-5200 ZEXEL 9 461 610 229 BOSCH SHIM 9461610229 1464205200 8941116590


 

Information shim

BOSCH 9 461 610 229 9461610229
ZEXEL 146420-5200 1464205200
ISUZU 8941116590 8941116590
146420-5200 SHIM
Rating:
85
Buy SHIM 146420-5200 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
146420-5200 
9 461 610 229 
8941116590  ISUZU
SHIM
C 11FV SHIM parts(VE) Others
146420-5200 
9 461 610 229 
ME741122  MITSUBISHI
SHIM
C 11FV SHIM parts(VE) Others
146420-5200 
9 461 610 229 
168845C909  NISSAN
SHIM
C 11FV SHIM parts(VE) Others
146420-5200 
9 461 610 229 
168845C909  NISSAN-DIESEL
SHIM
A C 11FV SHIM parts(VE) Others
146420-5200 
9 461 610 229 
RFS113V95  MAZDA
SHIM
C 11FV SHIM parts(VE) Others




Information:


Illustration 1 g00565418
4W-8471 Time Delay Relay
Use a 6V-7070 Digital Multimeter, a stopwatch, and a battery (8 volts to 40 volts) for this test.
Connect the positive lead of the voltage source to terminal (TD-4) of the time delay relay. Connect the negative lead to terminal (TD-3). If the test is done on an engine, the start/stop switch must be in the STOP position in order to power terminal (TD-6). All connections must be maintained until the tests are completed.
Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 1
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Connect the positive lead of the voltage source to terminal (TD-1). If the time delay relay is tested on the engine do not leave the voltage source hooked to terminal (TD-1) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 2
Terminals     Relay Position    
5-6     Open    
6-7     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 3
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    Note: If a jumper is normally installed across terminals (TD-2) and (TD-3), the jumper must be removed before performing Step 5.
Connect the positive lead of the voltage source to terminal (TD-2). If the time delay relay is tested on the engine, do not leave the voltage source on terminal (TD-2) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 4
Terminals     Delay Time of Relay Position    
0 to 8 seconds 10 seconds or more    
5-6     Closed     Open    
6-7     Open     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 5
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    
Remove the voltage source from terminal (TD-4). Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 6
Terminals     Relay Position    
5-6     Closed    
6-7     Open    

Have questions with 146420-5200?





Group cross 146420-5200 ZEXEL

Isuzu 

146420-5200  
9 461 610 229 
8941116590 
SHIM

Mitsubishi 

146420-5200  
9 461 610 229 
ME741122 
SHIM

Nissan 

146420-5200  
9 461 610 229 
168845C909 
SHIM

Nissan-Diesel 

146420-5200  
9 461 610 229 
168845C909 
SHIM

Mazda 

146420-5200  
9 461 610 229 
RFS113V95 
SHIM
Back to top