154610-0420 ZEXEL F 019 Z7E 818 BOSCH RACK SENSOR ASSY f019z7e818 1546100420 211802750a


 

Information rack sensor assy

BOSCH F 019 Z7E 818 f019z7e818
ZEXEL 154610-0420 1546100420
HINO 211802750A 211802750a
154610-0420 RACK SENSOR ASSY
Rating:
16
Buy RACK SENSOR ASSY 154610-0420 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 65
RACK SENSOR ASSY
1059211101 as RACK SENSOR ASSY

Cross reference number

Zexel num
Bosch num
Firm num
Name
154610-0420 
F 019 Z7E 818 
211802750A  HINO
RACK SENSOR ASSY
C 14GJ RACK SENSOR ASSY GOV
154610-0420 
F 019 Z7E 818 
19320Z9000  NISSAN-DIESEL
RACK SENSOR ASSY
C 14GJ RACK SENSOR ASSY GOV
154610-0420 
F 019 Z7E 818 
25952Z5504  NISSAN-DIESEL
RACK SENSOR ASSY
A C 14GJ RACK SENSOR ASSY GOV




Information:


Table 1
S O S Oil Analysis Guidelines    
Test Parameter     Guideline    
Oxidation     (1)    
Soot     (1)    
Sulfation     (1)    
Wear Metals     Trend Analysis and Cat Wear Table (1) norms    
Water     0.5% maximum    
Glycol     0%    
Fuel Dilution     Based on viscosity (1) and GC (2) fuel dilution in excess of 4%    
Viscosity "ASTM D445" measured at 100° C (212° F)     +/-3 centistokes (cSt) change from new oil viscosity.    
( 1 ) Acceptable values for these parameters are proprietary to the S O S oil analysis program.
( 2 ) Gas ChromatographConsult your Caterpillar dealer for complete information and assistance about the S O S oil analysis program.Obtaining S O S Oil Samples
Before you obtain an S O S oil sample, operate the engine until the oil is warm and the oil is well circulated. Then obtain the S O S oil sample.In order to obtain a good oil sample, do not take the oil sample from the drain stream. The drain stream method can allow a stream of dirty oil from the bottom of the compartment to contaminate the sample. Likewise, never dip an oil sample from an oil container or pour a sample from a used filter.There are two acceptable ways to obtain S O S oil samples. The following methods are listed in the order that is preferred:
Use an in-line sampling valve on the pressurized oil manifold.
Use a sampling gun (vacuum pump) that is inserted into the sump.Use of the in-line sampling valve is the preferred method. This method provides samples that are less likely to be contaminated. In order to obtain an oil sample from the engine, it may be necessary to increase the engine's speed. Normally, the oil sample is taken at low idle. If the flow rate is too low, increase engine speed to high idle in order to obtain the oil sample.
Do not use the same vacuum sampling pump for extracting oil samples that is used for extracting coolant samples.A small residue of either type sample may remain in the pump and may cause a false positive analysis for the sample being taken.Always use a separate pump for oil sampling and a separate pump for coolant sampling.Failure to do so may cause a false analysis which could lead to customer and dealer concerns.
Oil Sampling Interval
Take the oil samples as close as possible to the standard intervals. In order to receive the full value from S O S oil analysis, you must establish a consistent trend of data. In order to establish pertinent history of data, perform consistent oil samplings that are evenly spaced.
Table 2
Compartment     Engine    
Recommended Sampling Interval    
24140 kilometers (15000 miles)
(1) (2)    
Sampling Valve     Yes    
Oil Type     DEO, DEO-ULS    
Recommended Oil Change Interval     (3)    
( 1 ) Under certain conditions, the Caterpillar dealer or the Operation and Maintenance Manual may allow a longer

Have questions with 154610-0420?





Group cross 154610-0420 ZEXEL

Hino 

154610-0420  
F 019 Z7E 818 
211802750A 
RACK SENSOR ASSY

Nissan-Diesel 

154610-0420  
F 019 Z7E 818 
19320Z9000 
RACK SENSOR ASSY
154610-0420  
F 019 Z7E 818 
25952Z5504 
RACK SENSOR ASSY
Back to top