152061-0020 ZEXEL 9 440 610 146 BOSCH PUMP HOUSING 9440610146 1520610020 225641250a


 

Information pump housing

BOSCH 9 440 610 146 9440610146
ZEXEL 152061-0020 1520610020
HINO 225641250A 225641250a
152061-0020 PUMP HOUSING
Rating:
14
Buy PUMP HOUSING 152061-0020 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
152061-0020 
9 440 610 146 
225641250A  HINO
PUMP HOUSING
C 14GD HOUSING;F.P. F/P
152061-0020 
9 440 610 146 
ME738100  MITSUBISHI
PUMP HOUSING
C 14GD HOUSING;F.P. F/P
152061-0020 
9 440 610 146 
1664899014  NISSAN-DIESEL
PUMP HOUSING
C 14GD HOUSING;F.P. F/P




Information:


Fuel Injection Line Without Support Bracket Two different fuel injection line arrangements are utilized. One arrangement uses a support bracket, the other does not.
Be sure the fuel injection line clamps are installed in the correct locations. Incorrectly installed clamps may allow the fuel injection lines to vibrate and become damaged. The damaged lines may leak and cause a fire.
(1) Clamp location dimensions are in reference to a vertical line (1) through the center of the number one fuel pump outlet. Align brackets in position to fuel lines such that when the fasteners are tightened no strain will be added to the fuel lines while tightening fasteners.(A) ... 35 3 mm (1.38 .12 in)(B) ... 165 13 mm (6.50 .51 in)(C) ... 187 1 mm (7.36 .04 in)(D) ... 187 3 mm (7.36 .12 in)(E) ... 282 3 mm (11.10 .12 in)(F) ... 314 13 mm (12.36 .51 in)(G) ... 457 3 mm (17.99 .12 in)(H) ... 529 3 mm (17.99 .12 in)Tighten metal-to-metal clamps to a torque of ... 2.3 N m (20 lb in) The 6V4980 Torque Screwdriver Tool Group is available for applying the correct torque. (2) Tighten fuel injection line nuts to ... 42 7 N m (31 5 lb ft)(3) Tighten nuts to ... 14 3 N m (10 2 lb ft)(4) Tighten retainer on adapter to ... 48 7 N m (35 5 lb ft)
Fuel Injection Line With Support Bracket
Be sure the fuel injection line clamps are installed in the correct locations. Incorrectly installed clamps may allow the fuel injection lines to vibrate and become damaged. The damaged lines may leak and cause a fire.
(1) Clamp location dimensions are in reference to a vertical line (1) through the center of the number one fuel pump outlet.Align brackets in position to fuel lines such that when the fasteners are tightened no strain will be added to the fuel lines while tightening fasteners.(A) ... 35 3 mm (1.38 .12 in)(B) ... 165 13 mm (6.50 .51 in)(C) ... 187 1 mm (7.36 .04 in)(D) ... 187 3 mm (7.36 .12 in)(E) ... 282 3 mm (11.10 .12 in)(F) ... 283 3 mm (11.14 .12 in)(G) ... 529 3 mm (17.99 .12 in)Tighten metal-to-metal clamps to a torque of ... 2.3 N m (20 lb in) The 6V4980 Torque Screwdriver Tool Group is available for applying the correct torque. (2) Tighten fuel injection line nuts to ... 42 7 N m (31 5 lb ft)(3) Tighten nuts to ... 14 3 N m (10 2 lb ft)(4) Tighten retainer on adapter to ... 48 7 N m (35 5 lb ft)

Have questions with 152061-0020?





Group cross 152061-0020 ZEXEL

Hino 

152061-0020  
9 440 610 146 
225641250A 
PUMP HOUSING

Mitsubishi 

152061-0020  
9 440 610 146 
ME738100 
PUMP HOUSING

Nissan-Diesel 

152061-0020  
9 440 610 146 
1664899014 
PUMP HOUSING
Back to top