141055-8300 ZEXEL 9 411 619 159 BOSCH PUMP HOUSING 9411619159 1410558300 8ba471800


 

Information pump housing

BOSCH 9 411 619 159 9411619159
ZEXEL 141055-8300 1410558300
NIIGATA-URAWA 8BA471800 8ba471800
141055-8300 PUMP HOUSING
Rating:
11
Buy PUMP HOUSING 141055-8300 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 1
PUMP HOUSING
1042683020 as PUMP HOUSING

Cross reference number

Zexel num
Bosch num
Firm num
Name
141055-8300 
9 411 619 159 
8BA471800  NIIGATA-URAWA
PUMP HOUSING
A 24XX HOUSING;PUMP PF parts PF
141055-8300 
9 411 619 159 
8BA471800  NIIGATA
PUMP HOUSING
A 24XX HOUSING;PUMP PF parts PF
141055-8300 
9 411 619 159 
8BA471800  NIIGATA-TEKKOU
PUMP HOUSING
A 24XX HOUSING;PUMP PF parts PF




Information:


Always determine the cause of the engine shutdown. Make necessary repairs before attempting restarting the engine.
Air Shutoff Solenoid (If Equipped)
This optional solenoid is located on top of the engine in the air inlet system. When the solenoid is activated, the solenoid mechanically shuts off inlet air to the engine. The solenoid can only be activated by the overspeed switch or the emergency stop switch. The air shutoff must be reset before the engine can be restarted.Fuel Shutoff Solenoid
This solenoid is located on the governor or on the fuel injection pump. When the solenoid is activated, the solenoid moves the fuel rack (either directly or through the governor) to the FUEL OFF position.Overspeed Shutoffs
Magnetic pickup, (1), mounted in the flywheel housing (2).A magnetic pickup mounted in the flywheel housing senses the passage of the flywheel ring gear teeth. Should the engine speed increase above the overspeed setting of the Electronic Overspeed Switch (118 percent of rated engine speed), the magnetic pickup will sense the overspeed and send a signal to the Electronic Overspeed Switch. The Electronic Overspeed Switch activates both the air (if equipped) and fuel shutoff solenoids.The shutoffs must be reset before the engine will restart. A reset button on the Electronic Overspeed Switch (in the junction box) must be pushed to open the overspeed switch. The air shutoff lever (at the top of the air inlet housing) must be manually reset.Oil Pressure Switches
Typical example of oil pressure switches, mounted in the rear of the junction box.An oil pressure switch has wires connected to the electrical system for alarm or shutoff functions. The oil pressure switch senses oil pressure at the bearing oil gallery. If sufficient oil pressure is not achieved after engine starting, or if the engine has been running normally and then loses oil pressure, the fuel shutoff solenoid is energized to shut the engine off. No resetting procedure is required.Engine Step Oil Pressure
This is an adjustable engine speed setting that protects the engine from a failure caused by too little oil pressure for a specified speed range. This option requires two different oil pressure switches. One switch has a high pressure rating- when the engine is running above the speed setting, the engine must maintain oil pressure higher than the switch rating. The other switch has a low pressure rating- an engine running below the speed setting must maintain oil pressure above the low switch rating.In an automatic start/stop system, an automatic reset switch is used.Water Temperature Contactor Switch
The water temperature contactor switch is located in the cylinder head. High water temperature closes the switch to activate an alarm or fuel shutoff. No resetting is required. The switch opens as the coolant cools.
The sensing element must be submerged in the coolant to operate. Be sure to have an adequate water supply in the jacket water system, or engine damage could result.
Water Level Switch
Typical water level switch, mounted on the side of an expansion tank.If the coolant water level drops below the minimum level, the switch

Have questions with 141055-8300?





Group cross 141055-8300 ZEXEL

Niigata-Urawa 

141055-8300  
9 411 619 159 
8BA471800 
PUMP HOUSING

Niigata 

141055-8300  
9 411 619 159 
8BA471800 
PUMP HOUSING

Niigata-Tekkou 

141055-8300  
9 411 619 159 
8BA471800 
PUMP HOUSING
Back to top