Information pump housing
BOSCH
9 411 615 662
9411615662
ZEXEL
134070-4021
1340704021

Rating:
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$3,553.91
12 Apr 2019
Parts Expr: Parts Express
HOUSING FOR MITSUBISHI: 1340704021
MITSUBISHI || All Brand new & rebuilt items comes with 1 year warranty. || HOUSING FOR MITSUBISHI: Â FORKLIFT. MB1340704021 MB1340704021 MITSUBISHI 1340704021 MB 1340704021 1340704021 MITSUBISHI1340704021 Â Â Â Â Â Â THIS PART IS ALSO LISTED UNDER THE FOLLOWING PART NUMBERS:
MITSUBISHI || All Brand new & rebuilt items comes with 1 year warranty. || HOUSING FOR MITSUBISHI: Â FORKLIFT. MB1340704021 MB1340704021 MITSUBISHI 1340704021 MB 1340704021 1340704021 MITSUBISHI1340704021 Â Â Â Â Â Â THIS PART IS ALSO LISTED UNDER THE FOLLOWING PART NUMBERS:
Include in ###:
Cross reference number
Zexel num
Bosch num
Firm num
Name
134070-4021
9 411 615 662
PUMP HOUSING
K 14FR HOUSING;PUMP parts(P,PD) Others
K 14FR HOUSING;PUMP parts(P,PD) Others
Information:
Table 2
Specifications for Pressure Loss
Direct Injection Fuel Systems    
Nozzle pressure must not drop below a gauge reading of
3450 kPa (500 psi) during a 5 second time interval.    
Nozzle pressure must drop below a gauge reading of
1380 kPa (200 psi) after an additional 25 second time interval. (1)    
( 1 ) A gauge reading of 0 kPa (0 psi) is acceptable after the first 5 second time interval has elapsed.
Illustration 3 g00923167
If the fuel nozzle is not within specifications, stop the test and do not use the fuel nozzle.Valve Opening Pressure Test
Slowly increase the pressure until fluid begins to flow from the tip of the fuel nozzle. Record this pressure as the VOP of the fuel nozzle.
Compare the test results to the specifications for the type of fuel nozzle that is being tested. Refer to Table 3, or Table 4.For precombustion chamber fuel systems, use these specifications:
Table 3
Specifications for Valve Opening Pressure
Precombustion Chamber Fuel Systems    
2760 to 5170 kPa (400 to 750 psi)    
Illustration 4 g00934108
If the VOP is not within specifications, stop the test and do not use the fuel nozzle.For direct injection fuel systems, use these specifications:
Table 4
Specifications for Valve Opening Pressure
Direct Injection Fuel Systems    
16500 to 21400 kPa (2400 to 3100 psi)    
Illustration 5 g00923174
If the VOP is not within specifications, stop the test and do not use the fuel nozzle.Tip Leakage Test (Direct Injection Fuel Systems)
Note: Fuel nozzles for precombustion chamber fuel systems can not be tested for tip leakage accurately. Do not perform this test on fuel nozzles for a precombustion
Have questions with 134070-4021?
Group cross 134070-4021 ZEXEL
134070-4021
9 411 615 662
PUMP HOUSING