133051-3520 ZEXEL 9 411 615 113 BOSCH PUMP HOUSING 9411615113 1330513520


 

Information pump housing

BOSCH 9 411 615 113 9411615113
ZEXEL 133051-3520 1330513520
133051-3520 PUMP HOUSING
Rating:
10
Buy PUMP HOUSING 133051-3520 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 1
PUMP HOUSING
1030663730 as PUMP HOUSING

Cross reference number

Zexel num
Bosch num
Firm num
Name
133051-3520 
9 411 615 113 
   
PUMP HOUSING
K 14FN HOUSING;PUMP parts(B,Z) Others




Information:


Table 1
Diagnostic Trouble Codes
J1939 Code and Description CDL Code and Description
4334–20
Aftertreatment #1 DEF #1 Pressure (absolute) : Data Drifted High 3090–20
Aftertreatment #1 DEF Pressure Sensor : Data Drifted High
4334-21
Aftertreatment #1 DEF #1 Pressure (absolute) : Data Drifted Low 3090-21
Aftertreatment #1 DEF Pressure Sensor : Data Drifted Low
3361-5
Aftertreatment #1 DEF Dosing Unit : Current Below Normal 3821-5
Aftertreatment #1 Diesel Exhaust Fluid Dosing Valve Actuator : Current Below Normal
3361-6
Aftertreatment #1 DEF Dosing Unit : Current Above Normal 3821-6
Aftertreatment #1 Diesel Exhaust Fluid Dosing Valve Actuator : Current Above Normal
3516-12
Aftertreatment #1 DEF Concentration : Failure 3100-12
Aftertreatment #1 DEF Tank Fluid Quality Sensor : Failure
Table 2
Event Codes
J1939 Code and Description CDL Code and Description
5392-31
Aftertreatment Diesel Exhaust Fluid Dosing Unit Loss of Prime E1370 (2)
Aftertreatment #1 DEF Dosing Unit Loss of Prime
4334-18
Aftertreatment #1 DEF #1 Pressure (absolute) : Low - moderate severity (2) E931 (2)
Low Aftertreatment #1 DEF Pressure
4334-16
Aftertreatment #1 DEF #1 Pressure (absolute) : High - moderate severity (2) E930 (2)
High Aftertreatment #1 DEF Pressure
3516-16
Aftertreatment #1 DEF Concentration : High - moderate severity (2) E1365 (2)
High Aftertreatment #1 DEF Concentration
3516-18
Aftertreatment #1 DEF Concentration : Low - moderate severity (2) E1364 (2)
Low Aftertreatment #1 DEF Concentration
5246-15
Aftertreatment SCR Operator Inducement Severity : High - least severe (1) E1389 (1)
Aftertreatment #1 SCR Operator Inducement
5246-16
Aftertreatment SCR Operator Inducement Severity : High - moderate severity (2) E1389 (2)
Aftertreatment #1 SCR Operator Inducement
5246-0
Aftertreatment SCR Operator Inducement Severity : High - most severe (3) E1389 (3)
Aftertreatment #1 SCR Operator Inducement Ensure that DEF fluid conforms to specification ISO 22241 requirements and fluid handling, filling, and storage procedures are strictly followed.All transfer equipment and storage containers should be used exclusively for DEF and should not be reused for other fluids. For example coolants, fuels, oils, and windshield washer fluid.If contamination of the DEF system is suspected, refer to Troubleshooting, DEF Concentration is Incorrect. Ensure that the correct troubleshooting steps are followed. To test for contamination of the DEF tank, refer to Systems Operation Testing and Adjusting, Diesel Exhaust Fluid Quality - Test.If the DEF is contaminated, Caterpillar recommends that the DEF tank is flushed. Refer to Systems Operation Testing and Adjusting, Diesel Exhaust Fluid Tank - Flush for the correct procedure.

Have questions with 133051-3520?





Group cross 133051-3520 ZEXEL

133051-3520  
9 411 615 113 
 
PUMP HOUSING
Back to top