133050-8720 ZEXEL 9 411 611 712 BOSCH PUMP HOUSING 9411611712 1330508720


 

Information pump housing

BOSCH 9 411 611 712 9411611712
ZEXEL 133050-8720 1330508720
133050-8720 PUMP HOUSING
Rating:
62
Buy PUMP HOUSING 133050-8720 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 1
PUMP HOUSING
1030860101 as PUMP HOUSING

Cross reference number

Zexel num
Bosch num
Firm num
Name
133050-8720 
9 411 611 712 
   
PUMP HOUSING
K 14FN HOUSING;PUMP parts(B,Z) Others




Information:

Installing the Red LED Lamp (Regeneration Disable Lamp)
Illustration 1 g02402796
242-3282 Led Lamp As Use 155-2269 Connector Plug As as a mating connector. 155-2269 Connector Plug As is not included in the kit. Also, 102-8802 Receptacle Kit contains 3E-3364 Receptacle and 3E-3365 Receptacle Lock Wedge .
Insert the red (power) wire from the 242-3282 LED Lamp As into terminal 1 of 3E-3364 Receptacle .
Insert the black (ground) wire from the LED lamp into terminal 2 of the receptacle.
Insert 3E-3365 Receptacle Lock Wedge is the receptacle.
Connect terminal 1 of the receptacle to terminal 13 of 160-7689 Connector Plug As .
Connect terminal 2 of the receptacle to the ground/return (-).Installing the Illuminated Plug (Regeneration Lamp)
Illustration 2 g02402326
332-1064 Illuminated Plug The terminal designations can be found on the sides of 332-1064 Illuminated Plug and 205-5471 Connector .
Connect terminal 1A of the connector to the battery power (+).
Connect terminal 2A of the connector to the battery power (+).
Connect terminal 1B of the connector to terminal 30 of the plug.
Connect terminal 2B of the connector to terminal 31 of the plug.
Crimp the 112-9611 Blade Terminal onto the wires necessary to create the connections described in the previous steps.
Insert the blade terminals into the appropriate terminal locations of the connector.
Connect the plug to the connector. The plug and the connector are mating connectors.Installing the Hydraulic Lockout Rocker Switch (High Speed Regeneration Rocker Switch)
Illustration 3 g02366857
284-3623 Rocker Switch The terminal designations can be found on the sides of the 223-4778 Connector Plug As .
Insert 288-7146 Wire As into terminals 2,3,5, and 9 of the plug.
Splice the unoccupied ends of two 288-7146 Wire As together. Insert the spliced wire to provide a connection for terminal 6 to terminal 7 of 223-4778 Connector Plug As .
Connect terminal 2 of 223-4778 Connector Plug As to terminal 18 of 160-7689 Connector Plug As .
Connect

Have questions with 133050-8720?