131075-5320 ZEXEL 9 411 611 361 BOSCH PUMP HOUSING 9411611361 1310755320 221012350a


 

Information pump housing

BOSCH 9 411 611 361 9411611361
ZEXEL 131075-5320 1310755320
HINO 221012350A 221012350a
131075-5320 PUMP HOUSING
Rating:
32
Buy PUMP HOUSING 131075-5320 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 1
PUMP HOUSING
1010601510 as PUMP HOUSING

Cross reference number

Zexel num
Bosch num
Firm num
Name
131075-5320 
9 411 611 361 
221012350A  HINO
PUMP HOUSING
K 14FL HOUSING;PUMP parts(A,AD) Others




Information:


Table 1
Diagnostic Trouble Codes
J1939 Code and Description CDL Code and Description
4334–20
Aftertreatment #1 DEF #1 Pressure (absolute) : Data Drifted High 3090–20
Aftertreatment #1 DEF Pressure Sensor : Data Drifted High
4334-21
Aftertreatment #1 DEF #1 Pressure (absolute) : Data Drifted Low 3090-21
Aftertreatment #1 DEF Pressure Sensor : Data Drifted Low
3361-5
Aftertreatment #1 DEF Dosing Unit : Current Below Normal 3821-5
Aftertreatment #1 Diesel Exhaust Fluid Dosing Valve Actuator : Current Below Normal
3361-6
Aftertreatment #1 DEF Dosing Unit : Current Above Normal 3821-6
Aftertreatment #1 Diesel Exhaust Fluid Dosing Valve Actuator : Current Above Normal
3516-12
Aftertreatment #1 DEF Concentration : Failure 3100-12
Aftertreatment #1 DEF Tank Fluid Quality Sensor : Failure
Table 2
Event Codes
J1939 Code and Description CDL Code and Description
5392-31
Aftertreatment Diesel Exhaust Fluid Dosing Unit Loss of Prime E1370 (2)
Aftertreatment #1 DEF Dosing Unit Loss of Prime
4334-18
Aftertreatment #1 DEF #1 Pressure (absolute) : Low - moderate severity (2) E931 (2)
Low Aftertreatment #1 DEF Pressure
4334-16
Aftertreatment #1 DEF #1 Pressure (absolute) : High - moderate severity (2) E930 (2)
High Aftertreatment #1 DEF Pressure
3516-16
Aftertreatment #1 DEF Concentration : High - moderate severity (2) E1365 (2)
High Aftertreatment #1 DEF Concentration
3516-18
Aftertreatment #1 DEF Concentration : Low - moderate severity (2) E1364 (2)
Low Aftertreatment #1 DEF Concentration
5246-15
Aftertreatment SCR Operator Inducement Severity : High - least severe (1) E1389 (1)
Aftertreatment #1 SCR Operator Inducement
5246-16
Aftertreatment SCR Operator Inducement Severity : High - moderate severity (2) E1389 (2)
Aftertreatment #1 SCR Operator Inducement
5246-0
Aftertreatment SCR Operator Inducement Severity : High - most severe (3) E1389 (3)
Aftertreatment #1 SCR Operator Inducement Ensure that DEF fluid conforms to specification ISO 22241 requirements and fluid handling, filling, and storage procedures are strictly followed.All transfer equipment and storage containers should be used exclusively for DEF and should not be reused for other fluids. For example coolants, fuels, oils, and windshield washer fluid.If contamination of the DEF system is suspected, refer to Troubleshooting, DEF Concentration is Incorrect. Ensure that the correct troubleshooting steps are followed. To test for contamination of the DEF tank, refer to Systems Operation Testing and Adjusting, Diesel Exhaust Fluid Quality - Test.If the DEF is contaminated, Caterpillar recommends that the DEF tank is flushed. Refer to Systems Operation Testing and Adjusting, Diesel Exhaust Fluid Tank - Flush for the correct procedure.

Have questions with 131075-5320?





Group cross 131075-5320 ZEXEL

Hino 

131075-5320  
9 411 611 361 
221012350A 
PUMP HOUSING
Back to top