479771-5121 ZEXEL 9 443 611 739 BOSCH PULSE GENERATOR 9443611739 4797715121


 

Information pulse generator

BOSCH 9 443 611 739 9443611739
ZEXEL 479771-5121 4797715121
479771-5121 PULSE GENERATOR
Rating:
73
Buy PULSE GENERATOR 479771-5121 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 9
PULSE GENERATOR
1056900241 as PULSE GENERATOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
479771-5121 
9 443 611 739 
   
PULSE GENERATOR
479771-5121 
479771-5122 
9 443 611 739 
1157499391  ISUZU
PULSE GENERATOR
* C




Information:

This instruction is written for electronic technicians only, and must not be used by service personnel with no training or knowledge of electronics. For repairs that can be done by the Caterpillar Dealer Serviceman, with no knowledge of electronics, see Special Instruction Form SMHS6964 "Using 1P3500 and 2P8280 Injection Timing Groups."As an aid to the technician for troubleshooting the inverter and timing light, the following information is given in this instruction:1. Circuit board illustrations showing the position of each of the components and the test points (T) for using a voltmeter or an oscilloscope.2. Schematics of the electrical circuit so the technician can easily follow the sequence of the circuit.3. Test point values.4. Electrical parts replacement information.5. Timing light calibration procedure.Timing Light
1P3500 And 2P8280 Timing Lights - Electrical Schematic, Test Points And Parts List
Inverter - Electrical Schematic, Test Points And Parts List
There is a two position switch that is marked ADV.-RPM on the side of the 1P3499 Timing Light. When the timing light is in use, operation of the ADV.-RPM switch is as follows:RPM Position
A fuel injection pulse opens the switch in the transducer and starts a positive pulse (TP9) of fixed duration, from the monostable composed of Q2 and Q3. This pulse turns on a transistor switch Q4, allowing current to pass through meter M1, which mechanically averages pulses from an operating engine, and is calibrated to read RPM. Switch S2 grounds the gate of SCR1 to prevent the flash tube from strobing.ADV. Position
A fuel injection pulse again starts a pulse from the monostable. Adjustment of R7, the TIME-ADVANCE control, now determines the pulse duration from the monostable. When R7 is adjusted so that TDC on the damper coincides with the pointer on the block of an operating engine, the monostable pulse duration is exactly the same as the fuel system advance measured in seconds. Transistor switch Q4 again turns on, allowing current to pass through meter M1, causing a meter indicator that is calibrated in degrees of advance instead of seconds.Electrical Calibration Procedure
Before the electrical calibration can be done, the following equipment must be obtained.1) Oscilloscope with triggered sweep. Heath Co. M/N SO-4530 or equivalent.2) Signal generator. Heath M/N SG-72A or equivalent.3) Electronic counter. Data Precision M/N 5740 or equivalent.4) Electronic switch (dealer built).Calibration Procedure
(1) Hold the 1P3499 Timing Light in the same position (about a 45° angle) as if measuring the timing advance on an engine, and check the mechanical meter zero. Make an adjustment to zero if necessary. (2) To remove the protective rubber boot from the flash tube, twist the rubber boot and pull it away from the timing light as shown. (3) Remove the right side (side that has the serial number tag) of the timing light case.(4) Connect the 1P3499 Timing Light to a circuit like the one that follows. This will simulate (be the same as) a fuel flow transducer on an engine that is operating at 2400 RPM. (5) Turn the TIME-ADV. control counterclockwise (CCW) to its minimum

Have questions with 479771-5121?





Group cross 479771-5121 ZEXEL

 
 
PULSE GENERATOR

Isuzu 

 
1157499390 
PULSE GENERATOR
479771-5121  
9 443 611 739 
 
PULSE GENERATOR

Isuzu 

479771-5121  

479771-5122 
9 443 611 739 
1157499391 
PULSE GENERATOR
9 443 611 788 
 
PULSE GENERATOR

Isuzu 

9 443 611 788 
1157499392 
PULSE GENERATOR
Back to top