479771-5002 ZEXEL 9 443 611 787 BOSCH PULSE GENERATOR 9443611787 4797715002


 

Information pulse generator

BOSCH 9 443 611 787 9443611787
ZEXEL 479771-5002 4797715002
479771-5002 PULSE GENERATOR
Rating:
68
Buy PULSE GENERATOR 479771-5002 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 2
PULSE GENERATOR
1056900242 as PULSE GENERATOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
479771-5002 
9 443 611 787 
   
PULSE GENERATOR
75EA PICK UP SEN P/U
479771-5002 
9 443 611 787 
1157499382  ISUZU
PULSE GENERATOR
C 75EA PICK UP SEN P/U




Information:

You must read and understand the warnings and instructions contained in the Safety section of this manual, before performing any operation or maintenance procedures.Cooling System
Do not perform this maintenance until you read and understand the material in the Safety and Cooling System Specifications sections of this publication.
Drain/Flush/Replace Coolant (Long Life Coolant/Antifreeze Only)
Caterpillar Long Life Coolant/Antifreeze should be replaced every 6,000 Service Hours or 4 Years, whichever comes first. Only clean water is needed to clean and flush the cooling system when LLCA is drained and replaced.Drain
1. Stop the engine and allow the engine to cool. Loosen the coolant filler cap slowly to relieve any pressure, and remove the cap.2. Remove the radiator drain plug, or open the radiator drain valve (if equipped). Remove the block and oil cooler drain plugs. Remove the drain plug from the bottom of the water pump housing. Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. Contact your Caterpillar for information regarding disposal and recycling of used coolant.
For information regarding disposal and recycling of used coolant:Contact Caterpillar Service Technology Group:Outside Illinois: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOLFlush
3. Flush the cooling system with clean water to remove any debris.4. Clean and install all drain plugs and/or close the drain valve(s).5. Fill the cooling system with clean water. Install the filler cap. Operate the engine until warm 49 to 66°C (150 to 120°F).6. Stop the engine and allow the engine to cool. Loosen the coolant filler cap slowly to relieve any pressure, and remove the cap. Remove the cooling system drain plug(s) or open the drain valve. Allow the water to drain. Flush the cooling system with clean water.7. Repeat steps 6 and 7.Fill
8. Fill the cooling system with LLCA. Refer to the refill capacities chart in this manual for the amount of LLCA needed to refill your system.9. Start and run the engine with the filler cap removed. Allow the LLCA to warm, the thermostat to open, and the coolant level to stabilize. Add LLCA if necessary to bring the coolant to the proper level.10. Check the condition of the filler cap gasket. If the gasket is damaged, discard the old filler cap and install a new filler cap. If the gasket is not damaged, use a 9S8140 Service Tool (available from your Caterpillar dealer) to pressure test the filler cap. The correct filler cap pressure is stamped on the face of the filler cap. If the filler cap does not hold the correct pressure, install a new filler cap.11. Start the engine and inspect for coolant leaks and proper operating temperature.

Have questions with 479771-5002?





Group cross 479771-5002 ZEXEL

 
 
PULSE GENERATOR

Isuzu 

 
1157499380 
PULSE GENERATOR
9 443 611 738 
 
PULSE GENERATOR

Isuzu 

9 443 611 738 
1157499381 
PULSE GENERATOR
479771-5002  
9 443 611 787 
 
PULSE GENERATOR

Isuzu 

479771-5002  
9 443 611 787 
1157499382 
PULSE GENERATOR
Back to top