Buy 141156-1820 ZEXEL 9 443 611 322 BOSCH PLUNGER-AND-BARREL ASSY 9443611322 1411561820 0121713


 

Information plunger-and-barrel assy

BOSCH 9 443 611 322 9443611322
ZEXEL 141156-1820 1411561820
ISHIKAWAJIMA-H 0121713 0121713
141156-1820 PLUNGER-AND-BARREL ASSY
Rating:
12
Buy PLUNGER-AND-BARREL ASSY 141156-1820 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$69.98
 

25 Apr 2021

US: Franko Trade
Watts LFDPG5 2" Pressure Gauge Lead Free (0-160 psi)
Generic

Include in ###:

Number on scheme 5
PLUNGER-AND-BARREL ASSY
1041980061 as PLUNGER-AND-BARREL ASSY

Cross reference number

Zexel num
Bosch num
Firm num
Name
141156-1820 
9 443 611 322 
PC50 
0121713  ISHIKAWAJIMA-H
PLUNGER-AND-BARREL ASSY
C 26FJ PLUNGER ASSY PL(PF-PC for marine) PL




Information:


Table 2
Specifications for Pressure Loss
Direct Injection Fuel Systems    
Nozzle pressure must not drop below a gauge reading of
3450 kPa (500 psi) during a 5 second time interval.    
Nozzle pressure must drop below a gauge reading of
1380 kPa (200 psi) after an additional 25 second time interval. (1)    
( 1 ) A gauge reading of 0 kPa (0 psi) is acceptable after the first 5 second time interval has elapsed.
Illustration 3 g00923167
If the fuel nozzle is not within specifications, stop the test and do not use the fuel nozzle.Valve Opening Pressure Test
Slowly increase the pressure until fluid begins to flow from the tip of the fuel nozzle. Record this pressure as the VOP of the fuel nozzle.
Compare the test results to the specifications for the type of fuel nozzle that is being tested. Refer to Table 3, or Table 4.For precombustion chamber fuel systems, use these specifications:
Table 3
Specifications for Valve Opening Pressure
Precombustion Chamber Fuel Systems    
2760 to 5170 kPa (400 to 750 psi)    
Illustration 4 g00934108
If the VOP is not within specifications, stop the test and do not use the fuel nozzle.For direct injection fuel systems, use these specifications:
Table 4
Specifications for Valve Opening Pressure
Direct Injection Fuel Systems    
16500 to 21400 kPa (2400 to 3100 psi)    
Illustration 5 g00923174
If the VOP is not within specifications, stop the test and do not use the fuel nozzle.Tip Leakage Test (Direct Injection Fuel Systems)