140191-1720 ZEXEL 9 411 619 352 BOSCH PLUNGER-AND-BARREL ASSY 9411619352 1401911720


 

Information plunger-and-barrel assy

BOSCH 9 411 619 352 9411619352
ZEXEL 140191-1720 1401911720
140191-1720 PLUNGER-AND-BARREL ASSY
Rating:
56
Buy PLUNGER-AND-BARREL ASSY 140191-1720 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 900
PLUNGER-AND-BARREL ASSY
1042071000 as PLUNGER-AND-BARREL ASSY

Cross reference number

Zexel num
Bosch num
Firm num
Name
140191-1720 
140191-1721 
9 411 619 352 
   
PLUNGER-AND-BARREL ASSY
* K




Information:


TECHNICAL INFORMATION BULLETIN JAN. 15th, 2003
EXCAVATORS
WHEEL LOADERS
ENGINES 322C: (EMR, MAR);
325C: (CRB, CSJ, JLC, JLD, DTF)
950G II: (AYL, AYB);
962G II: (AYE, BAB)
3126B: (BMA)
Component Code(s) 1408SUBJECT: A NEW INJECTION ACTUATION PRESSURE CONTROL VALVE CONNECTOR INCREASES ENGINE OPERATION
PROBLEM:
The injection actuation pressure (IAP) control valve connector may have been assembled incorrectly on some 3126B engine harnesses. This can lead to intermittent engine operation or can cause the engine to stop.
SOLUTION:
If your machine exhibits symptoms of intermittent engine operation or abruptly stopping, the IAP control valve connector should be disconnected from the machine, examined for solenoid contact problems and re-installed using a correct procedure.
Procedure for installing the IAP control valve connector
This procedure will describe how to properly install the 232-4367 Harness.
Required Parts
Qty Part Number Description
1 232-4367 Harness
Procure the part that is listed in the table.
Illustration 1. Left Side of a 3126B Engine on a D6N.
(1) IAP Control Valve
(2) IAP Control Valve Connector
Note: Illustration 1 is from a D6N that is equipped with a 3126B for photographical purposes. The location of the IAP Control Valve is the same for your machine.
Disconnect the IAP control valve connector (2) from the IAP Control Valve (1). See Illustration 1.
Cut the two wires directly behind the connector.
Using wire strippers, strip the ends of the two wires.
Install the 232-4367 Harness, by crimping the stripped wires inside the splice.
Note: Take care to connect the pink wire to the pink wire on one hand and the purple wire to the purple wire on the other hand.
Heat both heat shrinkable tubes in order to insulate both the splices.
Reconnect the repaired harness to the IAP Control Valve (1).
COPYRIGHT 2003 CATERPILLAR
ALL RIGHTS RESERVED

Have questions with 140191-1720?





Group cross 140191-1720 ZEXEL

140191-1720  

140191-1721 
9 411 619 352 
 
PLUNGER-AND-BARREL ASSY
9 411 619 520 
 
PLUNGER-AND-BARREL ASSY
Back to top