Information plunger-and-barrel assy
BOSCH
9 443 610 560
9443610560
ZEXEL
134152-2520
1341522520
NISSAN-DIESEL
1679599203
1679599203

Rating:
Include in ###:
Number on scheme 7/2
1060615550
as PLUNGER-AND-BARREL ASSY
1060615551
as PLUNGER-AND-BARREL ASSY
P205
1060615580
as PLUNGER-AND-BARREL ASSY
1060615581
as PLUNGER-AND-BARREL ASSY
P205
1060617220
as PLUNGER-AND-BARREL ASSY
1060617531
as PLUNGER-AND-BARREL ASSY
P205
1060617540
as PLUNGER-AND-BARREL ASSY
1060617541
as PLUNGER-AND-BARREL ASSY
P205
1060617630
as PLUNGER-AND-BARREL ASSY
1060805191
as PLUNGER-AND-BARREL ASSY
P205
1060805390
as PLUNGER-AND-BARREL ASSY
1060805391
as PLUNGER-AND-BARREL ASSY
P205
1060805450
as PLUNGER-AND-BARREL ASSY
1060805451
as PLUNGER-AND-BARREL ASSY
P205
Cross reference number
Zexel num
Bosch num
Firm num
Name
134152-2520
9 443 610 560
1679599203 NISSAN-DIESEL
PLUNGER-AND-BARREL ASSY
C 14EU PLUNGER ASSY PL(P) PL
C 14EU PLUNGER ASSY PL(P) PL
Information:
Illustration 1 g00669441
CCM to Host Equipment Direct Connection (1) CCM (2) CCM RS-232C port (3) Computer RS-232C port (4) Host equipmentMake sure that the following equipment is available:
A personal computer. Refer to "Caterpillar CCM PC For Windows: Getting Started Manual" for specifications on the PC.
The proper RS-232C cables are required for the particular installation. Refer to the Operation and Maintenance Manual, "RS-232C Cable Requirements".
The CCM PC Software for Windows. This software is available from Caterpillar.ProcedurePerform the following procedure to initialize communication with the host equipment that is connected directly to the CCM.Note: The host equipment and the CCM should be turned OFF before you change the cables to the serial ports.
The CCM should be installed with all of the wiring. Refer to Operations and Maintenance Manual, "General Wiring Diagram" and "RS-232C Cable Requirements".
Determine the parameters for communication for the installation. The default rate of communication (bits per second or bps) is 9600. The remaining default settings from the factory are no parity, 8 data bits, and 1 stop bit. These parameters will work well in most installations. Use the Operations and Maintenance Manual, "Communication Parameters - Identify" to determine the parameters of communication that are stored in the CCM.
Load the CCM PC For Windows software into the PC. Refer to the "Caterpillar CCM PC For Windows: Getting Started Manual". Start the CCM PC program and connect to the CCM.
Go to the Data Link pull-down menu. Select ECM, CCM. Go to the CCM configuration screen in the Utilities menu. Set the parameters for communication to match the values that were chosen in step 2.
Use the CCM configuration screen to set the Connection Type to Direct Connection. The CCM is now set at the determined communication configuration.Note: If the PC is required to communicate with the CCM, go to the Phone Book pull-down menu and select Add or Edit. Set the communication parameters of the PC to the values that were chosen in Step 2.Note: The electronic controller of each engine must be programmed with the correct engine number for identification on the CCM. The electronic controller is programmed to Engine Number 1 at the factory. Refer to Operation and Maintenance Manual, SEBU6874, "Engine Number - Program".Note: After the CCM has been connected to the PC, refer to the "CCM PC Software Users Manual". This manual contains instructions on monitoring and on controlling the engine remotely.Note: Two conditions must be met before the electronic engine controller will allow control by the CCM. The Engine Control Switch must be in the AUTO position, and the remote initiate contacts must be open. The engine may be monitored with the ECS in any position.Note: For an EMCP II application, the CCM cannot control the generator set if the GSC is in Service Mode. The generator set can only be monitored.
Have questions with 134152-2520?
Group cross 134152-2520 ZEXEL
Nissan-Diesel
134152-2520
9 443 610 560
1679599203
PLUNGER-AND-BARREL ASSY