Buy 134152-2220 ZEXEL 9 443 611 106 BOSCH PLUNGER-AND-BARREL A 9443611106 1341522220


 

Information plunger-and-barrel a

BOSCH 9 443 611 106 9443611106
ZEXEL 134152-2220 1341522220
134152-2220 PLUNGER-AND-BARREL A
Rating:
62
Buy PLUNGER-AND-BARREL A 134152-2220 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$120.00

07 Jan 2025

ES: Auto i Center
Bosch 9443611106 Pump Element
Bosch

Include in ###:

Number on scheme 7/2
PLUNGER-AND-BARREL ASSY
1060670360 as PLUNGER-AND-BARREL ASSY

Cross reference number

Zexel num
Bosch num
Firm num
Name
134152-2220 
9 443 611 106 
   
PLUNGER-AND-BARREL A
C 14EU PLUNGER ASSY PL(P) PL




Information:


Illustration 1 g00656709
(1) Error code (2) Activity on CAT Data Link (3) First digit of error code (4) The CCM is transmitting on RS 232C. (5) Second digit of error code (6) The CCM is receiving data on the RS 232C.The values E, 0, and 0 indicate an error code of 00. The code E00 means that no faults are present, and the CCM is in normal operating mode. The complete list of error codes are in the Operation and Maintenance Manual, "Troubleshooting" section. The periods on the display will flash when information is transmitted on the CAT Data Link. The periods on the display will flash when information is transmitted on the RS-232C port. No period indicates that no activity is taking place.Note: Units with the part number 117-6170 Customer Communication Module will display the faults that have been logged. Each fault will be displayed for 2 seconds in 60 second intervals. This flashing fault log will not appear for any other version of CCM. The fault log can be cleared by using the PC software for the CCM.CCM Power Up Display
The CCM display will perform a lamp test (8.8.8.). The parameters for communication protocol (n81 9600 E00) will be displayed next. An example of the power up sequence is given below:
Table 1
8.8.8. n81 9600 E00    
8.8.8.     All of the segments are turned on for a two second lamp test.    
n81
n
8
1     No parity (default value)
Eight data bits (default value)
One stop bit (default value)    
9600     Rate of Communication (default value)    
E00     Error Code
No faults are present.    The values for communication can be changed by using a host device or by using the PC software for the CCM. Refer to "Caterpillar CCM PC For Windows: Getting Started Manual". The values for communication must match the values for the modems (if used) and the values for the host device.

Have questions with 134152-2220?





Group cross 134152-2220 ZEXEL

9 413 611 665 
P202 
 
PLUNGER
134152-2220  
9 443 611 106 
 
PLUNGER-AND-BARREL A
Back to top