Information plate
BOSCH
9 411 617 139
9411617139
ZEXEL
140217-7500
1402177500
ISUZU
8941289560
8941289560

Rating:
Include in ###:
Cross reference number
Zexel num
Bosch num
Firm num
Name
140217-7500
9 411 617 139
8941289560 ISUZU
PLATE
C 23XX PLATE PFR- parts PFR
C 23XX PLATE PFR- parts PFR
140217-7500
9 411 617 139
62156290530 ISEKI
PLATE
C 23XX PLATE PFR- parts PFR
C 23XX PLATE PFR- parts PFR
Information:
Introduction
Procedure to prevent injector Plunger Spring failure due to inadequate fuel system priming.
The low-pressure fuel system must be primed after injector replacement or other repair to the low-pressure fuel system circuit which may allow air to enter the system.
Inadequate priming can result in air being present in the low-pressure fuel system and inside the injectors.
Attempting to start the engine without adequate priming may result in an early hour failure of the injector plunger spring.
Follow the procedure below to prevent injector failure due to inadequate priming.
DO NOT START THE ENGINE WITHOUT PRIMING THE FUEL SYSTEM
Illustration 1 g03735591
Damaged plunger spring due to improper fuel system primingFuel System Priming Procedure:
Disconnect the injector harness at the valve cover.
Use the hand primer to fill the fuel system. Pump until the hand primer becomes too hard to depress by hand.
Crank the engine 3 times for 15 seconds each. Reapply the hand primer after each cranking cycle.
Once the hand primer remains hard to depress after the 15 second crank, reconnect the injector harness and start the engine.
Clear any related fault codes (ET) that were logged while cranking the engine with the injector harness disconnected.
Illustration 2 g03736011
Procedure to prevent injector Plunger Spring failure due to inadequate fuel system priming.
The low-pressure fuel system must be primed after injector replacement or other repair to the low-pressure fuel system circuit which may allow air to enter the system.
Inadequate priming can result in air being present in the low-pressure fuel system and inside the injectors.
Attempting to start the engine without adequate priming may result in an early hour failure of the injector plunger spring.
Follow the procedure below to prevent injector failure due to inadequate priming.
DO NOT START THE ENGINE WITHOUT PRIMING THE FUEL SYSTEM
Illustration 1 g03735591
Damaged plunger spring due to improper fuel system primingFuel System Priming Procedure:
Disconnect the injector harness at the valve cover.
Use the hand primer to fill the fuel system. Pump until the hand primer becomes too hard to depress by hand.
Crank the engine 3 times for 15 seconds each. Reapply the hand primer after each cranking cycle.
Once the hand primer remains hard to depress after the 15 second crank, reconnect the injector harness and start the engine.
Clear any related fault codes (ET) that were logged while cranking the engine with the injector harness disconnected.
Illustration 2 g03736011
Have questions with 140217-7500?
Group cross 140217-7500 ZEXEL
Isuzu
140217-7500
9 411 617 139
8941289560
PLATE
Iseki
140217-7500
9 411 617 139
62156290530
PLATE