146120-1620 ZEXEL 9 461 620 091 BOSCH OVER FLOW VALVE 9461620091 1461201620 167907t410


 

Information over flow valve

BOSCH 9 461 620 091 9461620091
ZEXEL 146120-1620 1461201620
NISSAN-DIESEL 167907T410 167907t410
146120-1620 OVER FLOW VALVE
Rating:
40
Buy OVER FLOW VALVE 146120-1620 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Cross reference number

Zexel num
Bosch num
Firm num
Name
146120-1620 
9 461 620 091 
167907T410  NISSAN-DIESEL
OVER FLOW VALVE
C 11FV OVER FLOW VALVE parts(VE) Others




Information:

Highly Recommended
The following equipment is highly recommended:
The Fluke 741B Multimeter is desired. 163-0096 Diagnostic and Calibration Tool
Ladder Viewer Diagnostic Software, YERA0162
The 4C-4029 Adjusting Tool Alternate Recommendations
The Milliampere Loop Simulator and TesterRTD Simulator and Tester Omega CL308Thermocouple Simulator and Tester Omega CL477The Simulator and Tester Omega CL26 for RTD and ThermocoupleThe Fluke 87 9U-7330 Digital Multimeter The Caterpillar Multimeter is also acceptable. 6V-7070 Digital Multimeter The attachments for the Fluke multimeter are in the following list:
Thermocouple Module 80TK is for reading thermocouples.
Immersion Probe 80PK2A can be used with self-sealing adapters.
8T-5200 Signal Generator/Counter is for checking the calibration of the speed switch and for simulating engine speed for the PLC.General Diagnostic Tools For the 3600
Reference: Engine News October 1990"Engine Commissioning and Diagnostic Tooling Kit".The following tools are used for measuring the pressures of the engine. The tools are also use for measuring the temperatures of the engine.
1U-5470 Engine Pressure Group
6V-9130 Temperature Adapter The following list contains the self-sealing adapters that are used for the installation of test ports in piping systems. The sizes of the adapters and the quantities of the adapters depend on the number of test ports that are needed.
5P-2725 Probe Seal Adapter
5P-3591 Probe Adapter
4C-4545 Probe Adapter Group
1U-8865 Infrared Thermometer
139-2788 Crimping Tool A Carrier-Oehler Calibration Pump is used in order to calibrate the setup for the alarms. The pump is also used in order to calibrate the shutdown setup.Contact information for the calibration pump:Carrier-Oehler Company
P.O. Box 40
16965 S. Vincennes
South Holland, Illinois USA 60473
ph: (708) 339-8200, fax: (708) 339-9830

Have questions with 146120-1620?





Group cross 146120-1620 ZEXEL

Nissan-Diesel 

146120-1620  
9 461 620 091 
167907T410 
OVER FLOW VALVE
Back to top