146120-0220 ZEXEL 9 461 610 097 BOSCH OVER FLOW VALVE 9461610097 1461200220 16790v0700


 

Information over flow valve

BOSCH 9 461 610 097 9461610097
ZEXEL 146120-0220 1461200220
NISSAN 16790V0700 16790v0700
146120-0220 OVER FLOW VALVE
Rating:
16
Buy OVER FLOW VALVE 146120-0220 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
146120-0220 
9 461 610 097 
16790V0700  NISSAN
OVER FLOW VALVE
C 11FV OVER FLOW VALVE parts(VE) Others
146120-0220 
9 461 610 097 
16790V0700  NISSAN-DIESEL
OVER FLOW VALVE
C 11FV OVER FLOW VALVE parts(VE) Others




Information:

Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The green "RUN" LED is illuminated. The processor is in the "RUN" mode.The red "FLT" LED is flashing during operation. The processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The amber "FORCE" LED is illuminated. The forces are enabled.The amber "FORCE" LED is not illuminated. No forces are present or no forces are enabled.
Illustration 1 g00563544
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Clear the fault.
Place the switch in the PROG position.
Place the switch in the RUN position.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Refer to Maintenance Procedure, "Processor - Replace".

Have questions with 146120-0220?





Group cross 146120-0220 ZEXEL

9 461 613 064 
 
EYE BOLT

Nissan 

146120-0220  
9 461 610 097 
16790V0700 
OVER FLOW VALVE

Nissan-Diesel 

146120-0220  
9 461 610 097 
16790V0700 
OVER FLOW VALVE
Back to top