131425-1820 ZEXEL 9 411 613 811 BOSCH OVER FLOW VALVE 9411613811 1314251820 1156194470


 

Information over flow valve

BOSCH 9 411 613 811 9411613811
ZEXEL 131425-1820 1314251820
ISUZU 1156194470 1156194470
131425-1820 OVER FLOW VALVE
Rating:
62
Buy OVER FLOW VALVE 131425-1820 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Cross reference number

Zexel num
Bosch num
Firm num
Name
131425-1820 
9 411 613 811 
A18 
1156194470  ISUZU
OVER FLOW VALVE
C 14GV OVER FLOW VALVE Others




Information:

Engine Runs Smoothly
Possible Causes/Corrections Dirty Air CleanerIf the air cleaner has a restriction indicator, see if the red piston is in view. If there is no restriction indicator, restriction can be checked with a water manometer or a vacuum gauge (which measures in inches of water). Make a connection to the piping between the air cleaner and the inlet of the turbocharger. Check with the engine running at full load rpm. Maximum restriction is 635 mm (25 in) of water. If a gauge is not available, visually check the air cleaner element for dirt. If the element is dirty, clean the element or install a new element. Air Inlet Piping Damage Or RestrictionMake a visual inspection of the air inlet system and check for damage to piping, rags in the inlet piping, or damage to the rain cap or the cap pushed too far on the inlet pipe. If no damage is seen, check inlet restriction with a clean air cleaner element. Exhaust System RestrictionMake a visual inspection of the exhaust system. Check for damage to piping or for a defective muffler. If no damage is found, you can check the system by checking the back pressure from the exhaust (pressure difference measurement between exhaust outlet and atmosphere). The back pressure must not be more than 1016 mm (40 in) of water. You can also check by removing the exhaust pipes from the exhaust manifolds. With the exhaust pipes removed, start and load the engine on a chassis dynamometer to see if the problem is corrected. Fuel Injection Timing Not CorrectCheck and make necessary adjustments as in Testing and Adjusting Section of this Service Manual. Fuel Setting Is Not CorrectCheck and make necessary adjustments as in Testing and Adjusting Section of this Service Manual. See the Fuel Setting And Related Information Fiche for the correct fuel setting. Low Quality FuelTest the engine with fuel according to recommendations by Caterpillar Inc. For more information see Special Instruction, Form No. SEHS7067, Fuel Recommendations For Caterpillar Diesel Engines. Also, Special Instruction, Form No. SEHS6947 has fuel correction factors and tables. Defective Fuel Nozzle(s)Defective fuel nozzles will normally cause the engine to misfire and run rough, but can cause too much smoke with engine still running smooth. Remove the fuel nozzles and test as in Testing and Adjusting Section of this Service Manual. Wrong Seal Washer Installed Under Nozzle(s)The use of incorrect washers change the location of the fuel injection nozzles in the combustion chamber. This effects smoke. Check the Engine Arrangement for the correct part number to use. Valve Adjustment Not Correct Or Valve LeakageCheck and make necessary adjustments as in Testing and Adjusting Section of this Service Manual. Intake valve lash is 0.38 mm (.015 in) and exhaust valve lash is 0.64 mm (.025 in). Valve leakage normally causes the engine to misfire and run rough. Defective Fuel Injection PumpAn injection pump can have a good fuel flow coming from it but cause rough running because of slow timing that

Have questions with 131425-1820?





Group cross 131425-1820 ZEXEL

Isuzu 

131425-1820  
9 411 613 811 
A18 
1156194470 
OVER FLOW VALVE
Back to top