Buy 105141-2240 ZEXEL 9 430 610 007 BOSCH NOZZLE AND HOLDER ASSY. 9430610007 1051412240 s21013640


 

Information nozzle and holder assy.

BOSCH 9 430 610 007 9430610007
ZEXEL 105141-2240 1051412240
MAZDA S21013640 s21013640
105141-2240 NOZZLE AND HOLDER ASSY.
Rating:
15
Buy NOZZLE AND HOLDER ASSY. 105141-2240 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
£125.83
 

10 Apr 2018

Bosch: Bosch
Bosch 9430610007 Nozzle And Holder Assy
1426 BOSCH nozzle Nhalter combination

Cross reference number

Zexel num
Bosch num
Firm num
Name
105141-2240 
9 430 610 007 
71-1530 
S21013640  MAZDA
NOZZLE AND HOLDER ASSY.
S2 K 53KG NOZZLE & HOLDER ASSY N&NH KCA-S N&NH




Information:

The heat baths listed in Chart B meet the specified requirements and can be purchased from:Cole-Parmer Instruments Co.
7425 North Oakpark Ave.
Niles, IL, 60714 U.S.A.
Phone (800) 323-4340
Fax: (708) 647-9660
* Heat Bath Fluid The heat bath fluid must be able to obtain and maintain the required contactor actuation and deactuation temperatures. For the temperatures required for the calibration procedure, silicone fluid must be used. Silicone fluid has a temperature range between 10° C (50° F) and 230° C (446° F). Silicone fluid can be purchased from Cole-Parmer by ordering G-01294-40. The fluid comes in a 3.8 Liter (1 gal) container.
Use extreme caution around heat baths with high temperature fluids. High temperature fluids can cause severe burns.
Calibration Procedure
Use the following procedure to test and calibrate the temperature contactors.1. If connected, disconnect the contactor from the power supply. Mark the terminal location and disconnect the three wires from terminals 1, 2, and 4.
High voltage electrical shock is possible. The contactor must be disconnected from the power supply and the wires disconnected from terminals 1, 2, and 4. Failure to follow this recommendation can result in serious bodily injury.
2. Locate and record the part number of the temperature contactor in Chart A. This will determine the actuation and deactuation temperatures. If the temperature contactor is used in extreme ambient temperatures there will be a scale deviation from the required actuation and deactuation temperatures. Refer to the "Calculating Scale Correction for Severe Temperature Applications" section in this Special Instruction.
Temperature Contactor
(1) Housing cover. (2) Housing cover screws. (3) Temperature probe. (4) Capillary tube.3. Loosen housing cover screws (2) and remove housing cover (1).4. Fill the heat bath unit with silicone fluid and heat it to approximately 5° C (10° F) below the actuation temperature setting. Do not immerse the temperature probe at this time.
Nomenclature Of Internal Parts
(5). Lock screw. (6) Range spindle. (7) Range scale. (8) Differential spindle. (9) Differential scale.5. Loosen lock screw (5).6. Adjust range spindle (6) to a setting above the desired actuation setting determined in Step 2. Determine the setting by using range scale (7).7. Adjust the differential spindle (8) to the approximate mechanical differential temperature using differential scale (9). Mechanical differential temperature is the difference between the actuation and deactuation temperature settings.
Temperature Control Function For Actuation And Deactuation (specifically shown for 7C-3888 Contactor)
Adjusting Temperature and Differential Settings On The Temperature Contactor
This example shows the temperature set at 66° C with an 8° C differential setting. This results in a deactuation temperature of 58° C and actuation temperature of 66° C. (Refer to "Temperature Control Function For Actuation And Deactuation" illustration.)8. Fully immerse temperature probe (3) in the silicone fluid. Increase the heat bath temperature to the specified actuation temperature.9. When the actuation temperature has stabilized, very slowly turn range spindle (6) counterclockwise until the contact actuates. This will be accompanied by an audible "click".
When Contact Actuates, Terminals 1 And 4 Will Have Continuity10. Use a 6V-7070 Multimeter, or equivalent, to verify the actuation of the contactor. Check for continuity between

Have questions with 105141-2240?





Group cross 105141-2240 ZEXEL

Ishikawajima-S 

9 430 610 337 
71-0640 
131406220 
NOZZLE AND HOLDER ASSY.
Y3041
9 430 610 338 
71-0650 
131406230 
NOZZLE AND HOLDER ASSY.
Y3041
 
 

M1

Ishikawajima-S 

9 430 610 339 
71-0660 
131406200 
NOZZLE AND HOLDER ASSY.
LEP854A

Mazda 

105141-2240  
9 430 610 007 
71-1530 
S21013640 
NOZZLE AND HOLDER ASSY.
S2
9 430 610 340 
71-0670 
S21313640 
NOZZLE AND HOLDER ASSY.
P713
9 430 613 418 
71-0671 
 
NOZZLE AND HOLDER ASSY.

Nissan 

9 430 610 008 
71-1360 
 
NOZZLE AND HOLDER ASSY.
CD17
9 430 610 018 
71-1361 
1660016A00 
NOZZLE AND HOLDER ASSY.
CD17

Mazda 

9 430 610 019 
71-0590B 
SE0813640 
NOZZLE AND HOLDER ASSY.
HA
9 430 613 419 
71-0591B 
 
NOZZLE AND HOLDER ASSY.

Isuzu 

9 430 610 341 
71-1370 
5153001170 
NOZZLE AND HOLDER ASSY.
4FA1
9 430 610 342 
71-1380T 
5153001171 
NOZZLE AND HOLDER ASSY.
4FA1

Toyo-Sha 

9 430 610 343 
71-0570H 
 
NOZZLE AND HOLDER ASSY.
CS100
Back to top