Buy 105119-4030 ZEXEL 9 430 613 879 BOSCH NOZZLE AND HOLDER ASSY. 9430613879 1051194030 4063526


 

Information nozzle and holder assy.

BOSCH 9 430 613 879 9430613879
ZEXEL 105119-4030 1051194030
KOMATSU 4063526 4063526
105119-4030 NOZZLE AND HOLDER ASSY.
Rating:
48
Buy NOZZLE AND HOLDER ASSY. 105119-4030 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$66.99
 

08 Mar 2022
0.66[0.30] Pounds
CN: china lutong part pl
Injector Nozzle Tips DLLA140P1181 0433171748 fits Cummins Injector 4063526 ​4pcs/lot
DICSCL PARCS Injector Nozzle Tips DLLA140P1181 0433171748 fits Cummins Injector 4063526 ​4pcs/lot || Material: Made of high quality for longer durability and strength.100% quality inspection to ensure the high quality. Upgraded packaging to avoid damage. || Easy Installation:No further modification to direct replacement. || OEM Part Number:DLLA140P1181 || Estimated Time of Delivery from China:5-10 working days.Customer satisfaction is always our top priority, we are standing by ready to provide you with reliable assistance with any questions you may have
$78.91
 

15 Sep 2019

Kilen: Kilen
Kilen Coil Spring (Front) 20109
Spring Design: Coil Spring; Coil Spring; Coil Spring; Coil Spring || Quality Product || Brand New

Cross reference number

Zexel num
Bosch num
Firm num
Name
105119-4030 
9 430 613 879 
4063526  KOMATSU
NOZZLE AND HOLDER ASSY.
6CTA K 53KF NOZZLE & HOLDER ASSY N&NH KBALP N&NH




Information:


Stopping the engine immediately after it has been working under load can result in overheating and accelerated wear of the engine components. Allow the engine to engine cool down before stopping. Avoiding hot engine shutdowns will maximize turbocharger shaft and bearing life.
If the engine has been operating at high load, run at low idle for at least three minutes before stopping. This cool down will reduce and stabilize internal engine coolant and oil temperatures before stopping the engine.If the engine has been operating at low loads, run the engine at low idle for 30 seconds before stopping.Make sure the shutoff procedure is understood. Refer to the Stopping the Engine instructions in the Generator Set Control Panel topic in this publication. Use the following general guidelines for stopping the engine.1. Open the Main electrical circuit breaker/Remove load from engine.2. Move the governor control to no more than half engine speed. Run the engine for three to five minutes.3. Reduce the engine speed to low idle.4. The engine may be stopped by using the Woodward Governor (if equipped), the Mechanical Governor (if equipped), or the solenoid shutoff switch.Woodward Actuator (If Equipped)
If equipped with a Woodward Actuator, move the control lever upward or forward, depending on the installation. Hold the lever to the OFF or STOP position until the engine stops.Mechanical Governor Control
A manual shutoff lever is provided to shut off the fuel from the fuel injection pump and override the governor control. The manual shutoff lever is located on the side of the pump.The engine can be shut OFF by rotating and holding the manual shutoff lever in the clockwise (CW) direction. If equipped with a Mechanical Governor Control, to move control to the SHUT OFF position: pull upward on the vernier hand grip while pushing down on thumb button. This shutdown will only move the fuel control linkage (rack) to the FUEL-OFF position. This does not shut off the air inlet.Solenoid Shutoff
Move the Control Panel Engine Control Switch (ECS, if equipped) to the STOP position.After Stopping the Engine
1. Fill the fuel tank to prevent accumulation of moisture in the fuel.2. Check the coolant level. Maintain the cooling system to 13 mm (1/2 inch) from bottom of the fill pipe. If freezing temperatures are expected, allow the radiator and engine jacket water system to cool, then check the coolant for proper antifreeze protection. The cooling system must be protected against freezing to the lowest expected ambient (outside) temperature. Add the proper coolant and water mixture if necessary.3. Check the crankcase oil level. Maintain the oil level between the ADD and FULL marks in the FULL RANGE zone on the dipstick.4. Repair any leaks, perform minor adjustments, tighten loose bolts, etc. 5. Note the service hour meter reading. Perform periodic maintenance as instructed in the Maintenance Schedule.

Have questions with 105119-4030?





Group cross 105119-4030 ZEXEL

Mitsubishi-Heav 

9 430 613 619 
48-4480B 
3436106060 
NOZZLE AND HOLDER ASSY.
S6K
9 430 613 618 
48-3390B1 
 
NOZZLE AND HOLDER ASSY.
CA498

Komatsu 

9 430 613 878 
4063524 
NOZZLE AND HOLDER ASSY.
6CTA
105119-4030  
9 430 613 879 
4063526 
NOZZLE AND HOLDER ASSY.
6CTA

Mitsubishi 

9 430 613 721 
48-3590F 
ME441640 
NOZZLE AND HOLDER ASSY.
6D34TL

Komatsu 

9 430 613 723 
48-3930A 
6222113600 
NOZZLE AND HOLDER ASSY.
SA6D108-

Tata 

9 430 613 726 
48-3251G 
1112100CC 
NOZZLE AND HOLDER ASSY.
4JB1

Komatsu 

9 430 613 799 
48-4450C 
6204113500 
NOZZLE AND HOLDER ASSY.
S4D95LE
9 430 613 785 
48-4450E 
6205113200 
NOZZLE AND HOLDER ASSY.
S4D95L

Mitsubishi-Heav 

9 430 613 808 
48-4530C 
3436503010 
NOZZLE AND HOLDER ASSY.
S6K-T
Back to top