Information nozzle-holder
BOSCH
9 430 615 020
9430615020
ZEXEL
105091-1140
1050911140
ISUZU
5153300510
5153300510

Rating:
Scheme ###:
4. | [1] | 150510-0700 | STOP PIN |
5. | [1] | 150515-5400 | SLOTTED WASHER |
6. | [1] | 150516-4600 | COMPRESSION SPRING |
8. | [1] | 150518-3500 | THREADED PIN |
9. | [1] | 029200-8160 | UNION NUT |
10. | [1] | 150520-6300 | CAP NUT |
11. | [1] | 029331-6030 | GASKET |
13. | [1] | 150524-0600 | SPACER BUSHING |
20. | [1] | 150639-2900 | NOZZLE-RETAINING NUT |
21. | [1] | 029300-5070 | GASKET D12&5T1 |
22. | [1] | 150644-9500 | INLET UNION |
27. | [1] | 139808-0000 | EYE BOLT |
28. | [2] | 139508-0000 | GASKET D13.2&8.2T1 |
Include in #1:
101461-0020
as NOZZLE-HOLDER
Cross reference number
Zexel num
Bosch num
Firm num
Name
105091-1140
9 430 615 020
5153300510 ISUZU
NOZZLE-HOLDER
K
K
Information:
Air Cleaner Indicator
This engine is equipped with an air cleaner mounted service indicator. A colored piston showing in the window indicates the need for servicing the air cleaner. Observe the air cleaner service indicator at regular scheduled intervals. Clean or replace the air cleaner element when the yellow diaphragm enters the red zone or the red piston locks in the visible position.If your air cleaner element becomes plugged, the air can split the element filter material. Unfiltered air will drastically accelerate internal engine wear. Excessive exhaust smoke and/or loss of power may indicate a need for air cleaner element inspection. Perform maintenance on the air cleaner as instructed in this topic.Keep spare filter elements on hand for replacement. The element should be thoroughly checked for rips or tears in the filter material, seal/gasket damage and replaced at least every year or 250 hours.Test Service Indicator
Air cleaner indicators are inexpensive but important instruments which function to show air filter element restriction as the element is progressively filled (plugged) with dust. In average dust conditions, the air cleaner indicators should be tested for proper operation Every 250 Hours . If dust is severe, the indicator should be checked Daily. To test the indicator, perform the following checks.* Check for ease of resetting; should reset in less than a maximum of three pushes.* Check the movement of the yellow core when the engine is accelerated to rated engine speed. The yellow core should latch at or very close to the highest vacuum obtained.If the indicator will NOT reset easily, or the yellow core will not latch at highest vacuum, the indicator(s) should be replaced. If the new indicator will not reset, the indicator sensor hole may be plugged.THE INDICATOR SHOULD BE REPLACED AT OVERHAUL AND/OR MAJOR ENGINE COMPONENT REPLACEMENT. THE INDICATOR MUST BE REPLACED EVERY YEAR REGARDLESS OF OPERATING CONDITIONS. When installing a new indicator, excessive tightening force may crack the top of the indicator. Tighten the indicator to a torque value of 2 N m (18 lb in). Contact your Caterpillar dealer for parts and/or assistance. Clean/Replace Air Cleaner Elements
Never service the air cleaner with the engine running since this will allow dirt to enter the engine. Check the inlet piping for leaks. Make all repairs to inlet piping immediately, as dirt and debris could enter the engine causing damage to the turbocharger and engine components.Clean or replace elements using these recommendations and/or your weather and operating conditions, or when required by the restriction indicator.
1. Remove air cleaner cover and element. Clean or discard used element. Refer to SEBF8062, Guideline for Reusable Parts-Cleaning and Inspection of Air Filters. 2. Cover air inlet opening with a clean cloth or towel to prevent dirt and debris from entering the engine. 3. Clean the inside of the air cleaner cover and body. 4. Remove cloth from air inlet opening and install clean element while noting arrows indicating air flow on the side of the element. 5. Install cover and reset service indicator.Cleaning
This engine is equipped with an air cleaner mounted service indicator. A colored piston showing in the window indicates the need for servicing the air cleaner. Observe the air cleaner service indicator at regular scheduled intervals. Clean or replace the air cleaner element when the yellow diaphragm enters the red zone or the red piston locks in the visible position.If your air cleaner element becomes plugged, the air can split the element filter material. Unfiltered air will drastically accelerate internal engine wear. Excessive exhaust smoke and/or loss of power may indicate a need for air cleaner element inspection. Perform maintenance on the air cleaner as instructed in this topic.Keep spare filter elements on hand for replacement. The element should be thoroughly checked for rips or tears in the filter material, seal/gasket damage and replaced at least every year or 250 hours.Test Service Indicator
Air cleaner indicators are inexpensive but important instruments which function to show air filter element restriction as the element is progressively filled (plugged) with dust. In average dust conditions, the air cleaner indicators should be tested for proper operation Every 250 Hours . If dust is severe, the indicator should be checked Daily. To test the indicator, perform the following checks.* Check for ease of resetting; should reset in less than a maximum of three pushes.* Check the movement of the yellow core when the engine is accelerated to rated engine speed. The yellow core should latch at or very close to the highest vacuum obtained.If the indicator will NOT reset easily, or the yellow core will not latch at highest vacuum, the indicator(s) should be replaced. If the new indicator will not reset, the indicator sensor hole may be plugged.THE INDICATOR SHOULD BE REPLACED AT OVERHAUL AND/OR MAJOR ENGINE COMPONENT REPLACEMENT. THE INDICATOR MUST BE REPLACED EVERY YEAR REGARDLESS OF OPERATING CONDITIONS. When installing a new indicator, excessive tightening force may crack the top of the indicator. Tighten the indicator to a torque value of 2 N m (18 lb in). Contact your Caterpillar dealer for parts and/or assistance. Clean/Replace Air Cleaner Elements
Never service the air cleaner with the engine running since this will allow dirt to enter the engine. Check the inlet piping for leaks. Make all repairs to inlet piping immediately, as dirt and debris could enter the engine causing damage to the turbocharger and engine components.Clean or replace elements using these recommendations and/or your weather and operating conditions, or when required by the restriction indicator.
1. Remove air cleaner cover and element. Clean or discard used element. Refer to SEBF8062, Guideline for Reusable Parts-Cleaning and Inspection of Air Filters. 2. Cover air inlet opening with a clean cloth or towel to prevent dirt and debris from entering the engine. 3. Clean the inside of the air cleaner cover and body. 4. Remove cloth from air inlet opening and install clean element while noting arrows indicating air flow on the side of the element. 5. Install cover and reset service indicator.Cleaning
Have questions with 105091-1140?
Group cross 105091-1140 ZEXEL
Isuzu
105091-1140
9 430 615 020
5153300510
NOZZLE-HOLDER