Buy 105078-0002 ZEXEL 9 430 615 644 BOSCH NOZZLE-HOLDER 9430615644 1050780002 8941311442


 

Information nozzle-holder

BOSCH 9 430 615 644 9430615644
ZEXEL 105078-0002 1050780002
ISUZU 8941311442 8941311442
105078-0002 NOZZLE-HOLDER
Rating:
86
Buy NOZZLE-HOLDER 105078-0002 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$91.78
 

13 Nov 2019

-: -
Bosch 9430615644 Nozzle-Holder Assembly

Scheme ###:

8. [1] 150562-4700 COMPRESSION SPRING
10. [1] 150560-0201 SLOTTED WASHER
18. [1] 150524-5300 SPACER BUSHING
22. [1] 150655-1400 NOZZLE-RETAINING NUT
800S/1. [0] 150534-2600 SHIM T0.1
800S/1. [0] 150534-2700 SHIM T0.2
800S/1. [0] 150534-2800 SHIM T0.3
800S/1. [0] 150534-2900 SHIM T0.4
800S/1. [0] 150534-3000 SHIM T0.5
800S/1. [0] 150534-3100 SHIM T0.52
800S/1. [0] 150534-3200 SHIM T0.54
800S/1. [0] 150534-3300 SHIM T0.56
800S/1. [0] 150534-3400 SHIM T0.58
800S/1. [0] 150534-3500 SHIM T0.8

Cross reference number

Zexel num
Bosch num
Firm num
Name
105078-0002 
9 430 615 644 
8941311442  ISUZU
NOZZLE-HOLDER
K 53LZ NOZZLE HOLDER NH NH




Information:

Introduction
The objective of this topic is to assist users in establishing a Preventive Maintenance Program for Standby Generator Sets or as an aid in evaluating their present programs.Standby Generator Sets may not be needed very often, but when they are, it is usually under emergency conditions. Maintenance of these standby units is very important. They must always be in excellent operating condition, ready to work under load at any time.Establishing a Preventive Maintenance Program will provide maximum availability of a standby generator set when needed, longer engine and generator life, and a minimum of expensive repairs.The recommended WEEKLY maintenance checks can be performed by an operator. The checks consist of basic maintenance requirements to ensure the standby generator set will be ready for immediate use should the need arise.All YEARLY and THREE YEAR maintenance should be performed by an authorized mechanic or your Caterpillar dealer. These checks and maintenance requirements will require that the standby generator be run under load conditions, and may require special test equipment.These guidelines are to be used with the information contained in the Operation and Maintenance sections of this manual. The Operation and Maintenance sections of the manual will provide the necessary information on how to perform the checks and routine maintenance.Refer to the Generator and Engine Service Manuals and Recommended Preventive Maintenance Schedules for Standby Generator Sets, SEBU6042 for additional information, or contact your Caterpillar dealer for assistance.Inspection and Maintenance Agreements
Your Caterpillar dealer can establish an Inspection and Preventive Maintenance Program for your generator set to provide maximum reliability, increased engine and generator life, and minimize expensive repairs. Contact your Caterpillar dealer for details.General Recommendations
Safety
The stop-manual-automatic switch on the cranking panel must be set at STOP position when performing maintenance or repair work on a standby generator set. This prevents the unit from starting if a power failure or voltage drop should occur while working on the unit.To prevent personal injury due to accidental starting of the engine, disconnect the batteries or disable the starting system before doing maintenance or repair work.Lock out all switch gear and automatic transfer switches associated with the generator while performing any generator maintenance or repairs. Make sure no shock hazard exists.Failure to comply could result in personal injury or death.
Always make repairs with the engine stopped and the starting system disabled. When servicing the generator, make sure that switch gear and automatic transfer switches will not present a shock hazard. Lock them out on the generator being serviced.Record Keeping
Maintain a log or record keeping system to document all gauge readings, problems, repairs, and maintenance performed on the equipment.Space Heaters
Moisture is a natural enemy of generators and all electrical equipment. Every effort must be made to keep the generator as dry as possible. Space heaters should be operated inside the generator when it is not in use to maintain the integrity of the generator windings.

Have questions with 105078-0002?





Group cross 105078-0002 ZEXEL

Isuzu 

9 430 615 049 
8941311440 
NOZZLE-HOLDER
9 430 615 051 
 
NOZZLE-HOLDER

Isuzu 

105078-0002  
9 430 615 644 
8941311442 
NOZZLE-HOLDER

Mitsubishi 

9 430 615 009 
ME722355 
NOZZLE-HOLDER

M.Bishi-Kyoto 

9 430 615 009 
ME722355 
NOZZLE-HOLDER
9 430 615 645 
 
NOZZLE-HOLDER
9 430 615 121 
 
NOZZLE-HOLDER
9 430 615 044 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 038 
 
NOZZLE-HOLDER

Mazda 

9 430 615 380 
PN1113TV0 
NOZZLE-HOLDER
9 430 616 418 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 646 
 
NOZZLE-HOLDER ASSEMBLY

Nissan 

9 430 615 042 
1661043G01 
NOZZLE-HOLDER

Nissan-Diesel 

9 430 615 042 
1661043G01 
NOZZLE-HOLDER

Yanmar 

9 430 615 042 
12990153020 
NOZZLE-HOLDER
9 430 615 189 
 
NOZZLE-HOLDER

Iseki 

9 430 615 322 
62153300070 
NOZZLE-HOLDER

Mitsubishi 

9 430 615 045 
ME722782 
NOZZLE-HOLDER
9 430 615 043 
 
NOZZLE-HOLDER

Mazda 

9 430 615 278 
PN2013TV0 
NOZZLE-HOLDER

Mitsubishi 

9 430 615 973 
ME723111 
NOZZLE-HOLDER
Back to top