105048-4130 ZEXEL 9 430 615 393 BOSCH NOZZLE-HOLDER 9430615393 1050484130 1661029d00


 

Information nozzle-holder

BOSCH 9 430 615 393 9430615393
ZEXEL 105048-4130 1050484130
NISSAN-DIESEL 1661029D00 1661029d00
105048-4130 NOZZLE-HOLDER
Rating:
28
Buy NOZZLE-HOLDER 105048-4130 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

8. [1] 150562-4300 COMPRESSION SPRING
10. [1] 150560-0400 SLOTTED WASHER
16. [2] 150508-5900 BEARING PIN
18. [1] 150524-4200 SPACER BUSHING
22. [1] 150655-0000 NOZZLE-RETAINING NUT
800S/1. [1] 150591-1000 SHIM D7.2&3.6T0.10
800S/1. [1] 150591-2000 SHIM D7.2&3.6T0.20
800S/1. [1] 150591-3000 SHIM D7.2&3.6T0.30
800S/1. [1] 150591-4000 SHIM D7.2&3.6T0.40
800S/1. [1] 150591-5000 SHIM D7.2&3.6T0.50
800S/1. [1] 150591-5100 SHIM D7.2&3.6T0.51
800S/1. [1] 150591-5200 SHIM D7.2&3.6T0.52
800S/1. [1] 150591-5300 SHIM D7.2&3.6T0.53
800S/1. [1] 150591-5400 SHIM D7.2&3.6T0.54
800S/1. [1] 150591-5500 SHIM D7.2&3.6T0.55
800S/1. [1] 150591-5600 SHIM D7.2&3.6T0.56
800S/1. [1] 150591-5700 SHIM D7.2&3.6T0.57
800S/1. [1] 150591-5800 SHIM D7.2&3.6T0.58
800S/1. [1] 150591-5900 SHIM D7.2&3.6T0.59

Cross reference number

Zexel num
Bosch num
Firm num
Name
105048-4130 
9 430 615 393 
1661029D00  NISSAN-DIESEL
NOZZLE-HOLDER
K 53LZ NOZZLE HOLDER NH NH




Information:


Spray starting fluid only while cranking the engine.
1. Heat the glow plugs (If equipped) for the approximate heating time shown in the STARTING AID CHART. 2. Turn the HEAT-START switch to START position. While cranking, spray starting fluid into the air inlet or air cleaner for approximately 1 second.
Wait at least 2 seconds before spraying starting fluid again.
3. If necessary, repeat the procedure.4. After the engine starts, it may be necessary to return the HEAT-START switch to the HEAT position until the engine runs smoothly.Jacket Water Heater (Attachment)
In very low temperatures, the lubricating oil must be warmed to allow starting. A jacket water heater can maintain the water temperature at approximately 90°F (32°C). The warm water will keep the oil in the upper part of the engine block warm enough to flow when starting.Dipstick Oil Heater
Contact your Caterpillar dealer before installing a dipstick crankcase oil heater.
Generator
Starting Single Unit Operation
1. Make all preliminary engine starting checks.2. Be sure the main or line circuit breaker is open.3. Start the engine and allow it to warm up.4. Close the main circuit breaker.5. Apply the load. Do not try to apply full load in one move, rather apply the load in increments to maintain system frequency at a constant level.Standby Generator Sets
Most standby units are automatic. They start, pickup the load, run and stop without an operator in attendance. Standby units can not change the governor control setting automatically. The throttle must be preset for the proper operation of that unit. Whenever the set is exercised or operated manually, be sure the throttle setting is correct for automatic operation. Check all switches to see they are properly set: Start Selector Switch in AUTOMATIC position and any Emergency Stop Switches in RUN position.Paralleling
Units may be paralleled at no load or paralleled with units under load. To parallel two or more units the following conditions must be met:1. Same phase rotation.2. Same voltage level.3. Same voltage droop.4. Same frequency.5. Voltages must be in phase.The first condition is established by "phased" wiring connections of initial installation.The second and third conditions are usually established by semi-permanent adjustments to the generator controls.The fourth and fifth conditions are under control of the operation in manual paralleling systems (or under automatic control in automatic paralleling systems).To Parallel
1. Start the unit to be paralleled.2. Turn the synchronizer lights on.3. After the engine has run long enough to warm up, bring it up to synchronous speed (the same frequency as the unit on the line). The synchronizing lights will begin to blink.4. Using the governor control, adjust the speed until the lights blink very slowly.5. The lights are off when the voltages of the two units are in phase. At this point, very quickly close the breaker while the lights are out. The frequency of the incoming unit should be slightly greater than the line frequency. This will allow the incoming unit to assume some of the load rather than add to the system load.Load Division
Once two units have been paralleled,

Have questions with 105048-4130?





Group cross 105048-4130 ZEXEL

9 430 615 592 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 833 
 
NOZZLE-HOLDER

Nissan-Diesel 

9 430 615 392 
16610Z5571 
NOZZLE-HOLDER
9 430 615 593 
 
NOZZLE-HOLDER ASSEMBLY

Nissan-Diesel 

105048-4130  
9 430 615 393 
1661029D00 
NOZZLE-HOLDER
9 430 615 594 
 
NOZZLE-HOLDER ASSEMBLY
 
 

Mitsubishi 

9 430 615 966 
ME748086 
NOZZLE-HOLDER
9 430 615 595 
 
NOZZLE-HOLDER ASSEMBLY

Nissan-Diesel 

9 430 615 447 
16610Z5576 
NOZZLE-HOLDER
9 430 615 394 
16610Z5577 
NOZZLE-HOLDER
Back to top