105048-4100 ZEXEL 9 430 615 592 BOSCH NOZZLE-HOLDER ASSEMBLY 9430615592 1050484100


 

Information nozzle-holder assembly

BOSCH 9 430 615 592 9430615592
ZEXEL 105048-4100 1050484100
105048-4100 NOZZLE-HOLDER ASSEMBLY
Rating:
24
Buy NOZZLE-HOLDER ASSEMBLY 105048-4100 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105048-4100 
9 430 615 592 
   
NOZZLE-HOLDER ASSEMBLY
K 53LZ NOZZLE HOLDER NH NH




Information:

Appendix
Configuration Information
Table 7
Over-Temp    
Inlet Over-Temperature Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output function     ON only during alarm    
    Assert Alarm     Above
650 °C (1202 °F)    
    Hysteresis    
20 °C (68 °F)    
    Upon Over Temperature extend alarm for 60 seconds    
Table 8
Over-Pres    
Over-Pressure Warning        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     ON only during alarm    
    Assert Alarm when the measured pressure exceeds 7" of Hg for 5% of the time during a 60 min measurement interval    
Over-Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 2    
    Output Function     Latched ON upon alarm    
    Assert alarm when the measured pressure exceeds 8" of Hg for 5% of the time during a 60 min measurement interval    
Table 9
TC-Fail (1)    
Open Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if measured temperature is above
1000 °C (1832 °F)    
Shorted Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if pressure is greater than 1" of Hg for 10 min and measured temperature does not exceed
120 °C (248 °F)    
( 1 ) Output selection applies to both open and shorted alarms
Table 10
Pressure Sensor Fail    
No Change Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Outputs During Alarm     Output 1    
    Output Function     Latched ON upon Alarm    
    Assert alarm if exhaust temperature is above
250 °C (482 °F) for 10 min and the pressure doesn't change by at least 0.25" of Hg    
Negative Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     Latched ON during alarm    
    Assert Alarm if temperature is above
200 °C (392 °F) for 10 min and the pressure is less than −1" of

Have questions with 105048-4100?





Group cross 105048-4100 ZEXEL

105048-4100  
9 430 615 592 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 833 
 
NOZZLE-HOLDER

Nissan-Diesel 

9 430 615 392 
16610Z5571 
NOZZLE-HOLDER
9 430 615 593 
 
NOZZLE-HOLDER ASSEMBLY

Nissan-Diesel 

9 430 615 393 
1661029D00 
NOZZLE-HOLDER
9 430 615 594 
 
NOZZLE-HOLDER ASSEMBLY
 
 

Mitsubishi 

9 430 615 966 
ME748086 
NOZZLE-HOLDER
9 430 615 595 
 
NOZZLE-HOLDER ASSEMBLY

Nissan-Diesel 

9 430 615 447 
16610Z5576 
NOZZLE-HOLDER
9 430 615 394 
16610Z5577 
NOZZLE-HOLDER
Back to top