105048-3230 ZEXEL 9 430 615 075 BOSCH NOZZLE-HOLDER 9430615075 1050483230 8970214180


 

Information nozzle-holder

BOSCH 9 430 615 075 9430615075
ZEXEL 105048-3230 1050483230
ISUZU 8970214180 8970214180
105048-3230 NOZZLE-HOLDER
Rating:
81
Buy NOZZLE-HOLDER 105048-3230 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

8. [1] 150562-4300 COMPRESSION SPRING
10. [1] 150560-0400 SLOTTED WASHER
16. [2] 150508-5900 BEARING PIN
18. [1] 150524-4600 SPACER BUSHING
22. [1] 150655-0000 NOZZLE-RETAINING NUT
800S/1. [1] 150591-1000 SHIM D7.2&3.6T0.10
800S/1. [1] 150591-2000 SHIM D7.2&3.6T0.20
800S/1. [1] 150591-3000 SHIM D7.2&3.6T0.30
800S/1. [0] 150591-4000 SHIM D7.2&3.6T0.40
800S/1. [1] 150591-5000 SHIM D7.2&3.6T0.50
800S/1. [1] 150591-5100 SHIM D7.2&3.6T0.51
800S/1. [1] 150591-5200 SHIM D7.2&3.6T0.52
800S/1. [1] 150591-5300 SHIM D7.2&3.6T0.53
800S/1. [1] 150591-5400 SHIM D7.2&3.6T0.54
800S/1. [1] 150591-5500 SHIM D7.2&3.6T0.55
800S/1. [1] 150591-5600 SHIM D7.2&3.6T0.56
800S/1. [1] 150591-5700 SHIM D7.2&3.6T0.57
800S/1. [1] 150591-5800 SHIM D7.2&3.6T0.58
800S/1. [1] 150591-5900 SHIM D7.2&3.6T0.59

Cross reference number

Zexel num
Bosch num
Firm num
Name
105048-3230 
9 430 615 075 
8970214180  ISUZU
NOZZLE-HOLDER
K 53LZ NOZZLE HOLDER NH NH
105048-3230 
9 430 615 075 
8944422250  ISUZU
NOZZLE-HOLDER
A K 53LZ NOZZLE HOLDER NH NH
105048-3230 
9 430 615 075 
8944548160  ISUZU
NOZZLE-HOLDER
C K 53LZ NOZZLE HOLDER NH NH




Information:


8T0900 AC/DC Clamp-On AmmeterThe 8T0900 AC/DC Clamp-On Ammeter is a completely portable, self-contained instrument that allows electrical current measurements to be made without breaking the circuit or disturbing the insulation on conductors. A digital display is located on the ammeter for reading current directly in a range from 1 to 1200 amperes. If a optional 6V6014 Cable is connected between this ammeter and one of the digital multimeters, current readings of less than 1 ammeter can then be read directly from the display of the multimeter.A lever is used to open the jaws over the conductor [up to a diameter of 19 mm (.75 in)], and the spring loaded jaws are then closed around the conductor for current measurement. A trigger switch that can be locked in the ON or OFF position is used to turn on the ammeter. When the turn-on trigger is released, the last current reading is held on the display for 5 seconds. This allows accurate measurements to be taken in limited access areas where the digital display is not visible to the operator. A zero control is provided for DC operation, and power for the ammeter is supplied by batteries located inside the handle. Make reference to Special Instruction, Form No. SEHS8420 for more complete information for use of the 8T0900 Clamp-On Ammeter.
6V7070 Heavy-Duty Digital MultimeterThe 6V7070 Heavy-Duty Digital Multimeter is a completely portable, hand held instrument with a digital display. This multimeter is built with extra protection against damage in field applications, and is equipped with seven functions and 29 ranges. The 6V7070 Multimeter has an instant ohms indicator that permits continuity checking for fast circuit inspection. It also can be used for troubleshooting small value capacitors.The 6V7800 Regular-duty Digital Multimeter (a low cost option to the Heavy-Duty Multimeter) is also available; however, the 6V7800 Multimeter does not have the 10A range or the instant ohms feature of the 6V7070 Multimeter. Make reference to Special Instruction, Form No. SEHS7734 for more complete information for use of the 6V7070 and 6V7800 Multimeters.Battery
Never disconnect any charging unit circuit or battery circuit cable from battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit will result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage will damage, not only the charging unit, but also the regulator and other electrical components.Use the 6V4930 Battery Load Tester, the 8T900 Clamp-On Ammeter and the 6V7070 Multimeter to load test a battery that does not hold a charge when in

Have questions with 105048-3230?





Group cross 105048-3230 ZEXEL

Komatsu 

9 430 616 036 
6204113410 
NOZZLE-HOLDER
9 430 615 144 
 
NOZZLE-HOLDER

Mitsubishi 

9 430 615 089 
ME730411 
NOZZLE-HOLDER
9 430 615 089 
ME016308 
NOZZLE-HOLDER

Isuzu 

9 430 615 110 
8944341760 
NOZZLE-HOLDER
105048-3230  
9 430 615 075 
8970214180 
NOZZLE-HOLDER
105048-3230  
9 430 615 075 
8944422250 
NOZZLE-HOLDER
105048-3230  
9 430 615 075 
8944548160 
NOZZLE-HOLDER

Mitsubishi 

 
ME722907 
NOZZLE-HOLDER
9 430 616 037 
ME727628 
NOZZLE-HOLDER

Isuzu 

9 430 616 038 
8944511840 
NOZZLE-HOLDER
9 430 616 038 
8972103900 
NOZZLE-HOLDER
9 430 615 281 
8944511841 
NOZZLE-HOLDER

Komatsu 

9 430 616 039 
6204113411 
NOZZLE-HOLDER

Mitsubishi 

9 430 616 016 
ME723109 
NOZZLE-HOLDER
9 430 615 446 
ME723110 
NOZZLE-HOLDER
9 430 616 165 
 
NOZZLE-HOLDER ASSEMBLY
Back to top