Information nozzle-holder
BOSCH
9 430 615 249
9430615249
ZEXEL
105041-7130
1050417130
KOMATSU
6152123110
6152123110

Rating:
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$3,620.33
16 Sep 2024
CN: David-Store
6152-12-3100 6152-12-3110 6152123100 6152123110 Fuel Injector Fits for Komatsu 6D125 Engine SA6D125E-2 PC400-6 WA470-3
CNCJNXW ★Part Name★:Fuel Injector || ★Part Number★:6152-12-3100 6152-12-3110 6152123100 6152123110 || ★Application★:Fits for Komatsu 6D125 Engine SA6D125E-2 PC400-6 WA470-3 || NOTE Please check the part number before purchase, do not only look at the appearance of the purchase, check the part number is the best way to reduce the error rate. If you are not clear, please contact us, we are very happy to serve you! || Worth Choice Our product quality is reliable, after-sales guarantee! If you have any questions, please contact us in time, communication is the best way to solve the problem!
CNCJNXW ★Part Name★:Fuel Injector || ★Part Number★:6152-12-3100 6152-12-3110 6152123100 6152123110 || ★Application★:Fits for Komatsu 6D125 Engine SA6D125E-2 PC400-6 WA470-3 || NOTE Please check the part number before purchase, do not only look at the appearance of the purchase, check the part number is the best way to reduce the error rate. If you are not clear, please contact us, we are very happy to serve you! || Worth Choice Our product quality is reliable, after-sales guarantee! If you have any questions, please contact us in time, communication is the best way to solve the problem!
$643.79
16 Sep 2024
CN: QYWD
6152123100 6152-12-3110 1X Fuel Injector for Komatsu 6D125 Engine PC400-6
TUWODE Part Number: 6152123100 6152-12-3110 || Item Type: Fuel Injector || Applicable Models: Fit for Komatsu 6D125 Engine PC400-6 || Well-functioning fuel injectors ensure the correct air-fuel ratio, which is essential for minimizing harmful emissions. || Fuel is broken into fine droplets for optimal air mixing and enhanced combustion efficiency.
TUWODE Part Number: 6152123100 6152-12-3110 || Item Type: Fuel Injector || Applicable Models: Fit for Komatsu 6D125 Engine PC400-6 || Well-functioning fuel injectors ensure the correct air-fuel ratio, which is essential for minimizing harmful emissions. || Fuel is broken into fine droplets for optimal air mixing and enhanced combustion efficiency.
Scheme ###:
2. | [1] | 029300-5070 | GASKET D12&5T1 |
4. | [1] | 150645-8100 | INLET UNION |
8. | [1] | 150562-6200 | COMPRESSION SPRING |
10. | [1] | 150550-5900 | STOP PIN |
16. | [2] | 150525-1701 | BEARING PIN |
18. | [1] | 150524-4300 | SPACER BUSHING |
19. | [2] | 150508-3300 | BEARING PIN |
22. | [1] | 150650-9400 | NOZZLE-RETAINING NUT |
40. | [2] | 029340-8110 | GASKET |
42. | [1] | 029730-8350 | EYE BOLT |
800S/1. | [1] | 150590-0600 | SHIM D9.9&4.8T0.40 |
800S/1. | [1] | 150590-0700 | SHIM D9.9&4.8T0.50 |
800S/1. | [1] | 150590-0800 | SHIM D9.9&4.8T0.52 |
800S/1. | [1] | 150590-0900 | SHIM D9.9&4.8T0.54 |
800S/1. | [1] | 150590-1000 | SHIM D9.9&4.8T0.56 |
800S/1. | [1] | 150590-1100 | SHIM D9.9&4.8T0.58 |
800S/1. | [1] | 150590-1200 | SHIM D9.9&4.8T0.60 |
800S/1. | [1] | 150590-1300 | SHIM D9.9&4.8T0.70 |
Include in #1:
106671-9270
as NOZZLE-HOLDER
Cross reference number
Zexel num
Bosch num
Firm num
Name
105041-7130
9 430 615 249
6152123110 KOMATSU
NOZZLE-HOLDER
K 53LZ NOZZLE HOLDER NH NH
K 53LZ NOZZLE HOLDER NH NH
Information:
Battery
9S1990 BATTERY CHARGER TESTER.The storage battery circuit represents a continuous, although variable, electrical load to the charging unit. If the circuit, positive or negative is opened or broken while the charging unit is charging, the loss of the battery load will result in the charging voltage rising to unsafe levels.High voltage will damage the charging unit and regulator and may damage other electrical components or instruments.NEVER DISCONNECT ANY CHARGING UNIT CIRCUIT OR BATTERY CIRCUIT CABLE FROM BATTERY WHEN THE CHARGING UNIT IS PRODUCING A CHARGE.A load test should be made on a battery that discharges very rapidly when in use. To do this apply a resistance of three times the ampere/hour rating of the battery across the battery main terminals. Allow the resistance to discharge the battery for 15 seconds and immediately test the battery voltage. A 12 volt battery in good condition will test 9 volts.The instructions included with the 9S1990 Battery Charger Tester completely covers the battery testing subject.Starting System
Use a D.C. voltmeter to locate starting system components which do not function.Turn the disconnect switch ON. Attach one voltmeter lead to the starter solenoid terminal connected to both a cable and a small wire. Ground the other voltmeter lead. No voltmeter reading indicates a defective disconnect switch. A voltmeter reading of battery voltage indicates further testing is necessary.Turn the HEAT-START switch to the START position. Starting motor solenoid operation is audible as the starter motor pinion engages with the ring gear on the engine flywheel. The solenoid operation should also close the electric circuit to the motor. Attach one voltmeter lead to the solenoid terminal that is connected to the motor. Ground the other lead. Turn the HEAT-START switch to START and observe the voltmeter. A battery voltage reading indicates the malfunction is in the motor. It must be removed for further testing. No voltmeter reading indicates that the solenoid contacts do not close and the solenoid must be repaired or the starter pinion clearance should be adjusted.A starting motor solenoid that will not operate may not be receiving battery current. Attach one lead of the voltmeter to the solenoid battery cable connection. Ground the other lead. No voltmeter reading indicates a defective disconnect switch. A voltmeter reading indicates further testing is necessary.Continue the test by attaching one voltmeter lead to the starting motor solenoid small wire terminal and the other lead to ground. Observe the voltmeter and turn the HEAT-START switch to START. A voltmeter reading indicates that the malfunction is in the solenoid. No voltmeter reading indicates that either the circuit breaker is defective or the HEAT-START switch does not close when turned to the START position.Attach one lead of the voltmeter to the HEAT-START switch battery wire terminal and ground the other lead. A voltmeter reading indicates a defective switch. No voltmeter reading indicates the circuit breaker points are open. If the circuit breaker reset button will not close the points the circuit breaker is defective.A starting motor that operates too slow can
9S1990 BATTERY CHARGER TESTER.The storage battery circuit represents a continuous, although variable, electrical load to the charging unit. If the circuit, positive or negative is opened or broken while the charging unit is charging, the loss of the battery load will result in the charging voltage rising to unsafe levels.High voltage will damage the charging unit and regulator and may damage other electrical components or instruments.NEVER DISCONNECT ANY CHARGING UNIT CIRCUIT OR BATTERY CIRCUIT CABLE FROM BATTERY WHEN THE CHARGING UNIT IS PRODUCING A CHARGE.A load test should be made on a battery that discharges very rapidly when in use. To do this apply a resistance of three times the ampere/hour rating of the battery across the battery main terminals. Allow the resistance to discharge the battery for 15 seconds and immediately test the battery voltage. A 12 volt battery in good condition will test 9 volts.The instructions included with the 9S1990 Battery Charger Tester completely covers the battery testing subject.Starting System
Use a D.C. voltmeter to locate starting system components which do not function.Turn the disconnect switch ON. Attach one voltmeter lead to the starter solenoid terminal connected to both a cable and a small wire. Ground the other voltmeter lead. No voltmeter reading indicates a defective disconnect switch. A voltmeter reading of battery voltage indicates further testing is necessary.Turn the HEAT-START switch to the START position. Starting motor solenoid operation is audible as the starter motor pinion engages with the ring gear on the engine flywheel. The solenoid operation should also close the electric circuit to the motor. Attach one voltmeter lead to the solenoid terminal that is connected to the motor. Ground the other lead. Turn the HEAT-START switch to START and observe the voltmeter. A battery voltage reading indicates the malfunction is in the motor. It must be removed for further testing. No voltmeter reading indicates that the solenoid contacts do not close and the solenoid must be repaired or the starter pinion clearance should be adjusted.A starting motor solenoid that will not operate may not be receiving battery current. Attach one lead of the voltmeter to the solenoid battery cable connection. Ground the other lead. No voltmeter reading indicates a defective disconnect switch. A voltmeter reading indicates further testing is necessary.Continue the test by attaching one voltmeter lead to the starting motor solenoid small wire terminal and the other lead to ground. Observe the voltmeter and turn the HEAT-START switch to START. A voltmeter reading indicates that the malfunction is in the solenoid. No voltmeter reading indicates that either the circuit breaker is defective or the HEAT-START switch does not close when turned to the START position.Attach one lead of the voltmeter to the HEAT-START switch battery wire terminal and ground the other lead. A voltmeter reading indicates a defective switch. No voltmeter reading indicates the circuit breaker points are open. If the circuit breaker reset button will not close the points the circuit breaker is defective.A starting motor that operates too slow can
Have questions with 105041-7130?
Group cross 105041-7130 ZEXEL
Komatsu
Komatsu
Komatsu
105041-7130
9 430 615 249
6152123110
NOZZLE-HOLDER