Illustration 1 g00565418
4W-8471 Time Delay Relay
Use a 6V-7070 Digital Multimeter, a stopwatch, and a battery (8 volts to 40 volts) for this test.
Connect the positive lead of the voltage source to terminal (TD-4) of the time delay relay. Connect the negative lead to terminal (TD-3). If the test is done on an engine, the start/stop switch must be in the STOP position in order to power terminal (TD-6). All connections must be maintained until the tests are completed.
Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 1
Terminals     Relay Position    
5-6     Closed    
6-7     Open    
Connect the positive lead of the voltage source to terminal (TD-1). If the time delay relay is tested on the engine do not leave the voltage source hooked to terminal (TD-1) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 2
Terminals     Relay Position    
5-6     Open    
6-7     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 3
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    Note: If a jumper is normally installed across terminals (TD-2) and (TD-3), the jumper must be removed before performing Step 5.
Connect the positive lead of the voltage source to terminal (TD-2). If the time delay relay is tested on the engine, do not leave the voltage source on terminal (TD-2) for more than 60 seconds. The fuel shutoff solenoid will be energized. Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 4
Terminals     Delay Time of Relay Position    
0 to 8 seconds 10 seconds or more    
5-6     Closed     Open    
6-7     Open     Closed    
Remove the positive lead of the voltage source from terminal (TD-1). Use the stopwatch to measure the time that is needed for the position of the relay to change. Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 5
Terminals     Delay Time of Relay Position    
0 to 60 seconds 80 seconds or more    
5-6     Open     Closed    
6-7     Closed     Open    
Remove the voltage source from terminal (TD-4). Use the multimeter to determine continuity. Compare the measurements to the following table.
Table 6
Terminals     Relay Position    
5-6     Closed    
6-7     Open    

Have questions with 105030-4710?





Group cross 105030-4710 ZEXEL

Isuzu 

9 430 615 290 
8943903840 
NOZZLE-HOLDER
105030-4710  
 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 442 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 581 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 425 
 
NOZZLE-HOLDER ASSEMBLY

Hino 

9 430 615 212 
236202460A 
NOZZLE-HOLDER
9 430 616 143 
 
NOZZLE-HOLDER ASSEMBLY

Isuzu 

9 430 615 291 
8971348410 
NOZZLE-HOLDER
9 430 616 185 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 265 
 
NOZZLE-HOLDER ASSEMBLY
9 430 616 404 
 
NOZZLE-HOLDER ASSEMBLY
9 430 616 145 
 
NOZZLE-HOLDER ASSEMBLY

Hino 

9 430 615 213 
236202500A 
NOZZLE-HOLDER
Back to top