105030-4640 ZEXEL 9 430 615 441 BOSCH NOZZLE-HOLDER ASSEMBLY 9430615441 1050304640


 

Information nozzle-holder assembly

BOSCH 9 430 615 441 9430615441
ZEXEL 105030-4640 1050304640
105030-4640 NOZZLE-HOLDER ASSEMBLY
Rating:
14
Buy NOZZLE-HOLDER ASSEMBLY 105030-4640 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

2. [2] 150508-3300 BEARING PIN
4. [1] 150550-3600 STOP PIN
6. [1] 150562-5100 COMPRESSION SPRING
8. [1] 150565-2001 THREADED PIN
10. [1] 150567-4200 CAP NUT
11. [1] 029331-4130 GASKET
20. [1] 150650-1701 NOZZLE-RETAINING NUT
21. [1] 150602-2700 GASKET D12&3.5T1.00
22. [1] 150645-3200 INLET UNION
30. [1] 150613-2100 EYE BOLT
31. [2] 139510-0300 GASKET

Include in #1:

106671-9530 as NOZZLE-HOLDER

Cross reference number

Zexel num
Bosch num
Firm num
Name
105030-4640 
9 430 615 441 
   
NOZZLE-HOLDER ASSEMBLY
K 53LZ NOZZLE HOLDER NH NH




Information:

Problem 5
The engine shutdown occurs after the engine runs for more than 3 minutes.
Check the overspeed setting on the electronic speed switch (ESS).
Observe the indicator lamp on the ESS.
Reset the air shutoff lever, if equipped.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The indicator lamp on the ESS is turned on.Overspeed is indicated as the cause of the engine shutdown. Press the "RESET" button of the ESS. Find the cause of the overspeed. Refer to Testing and Adjusting, "Overspeed Verification Test" and Testing and Adjusting, "Overspeed Calibration". If the overspeed is adjusted properly and the problem persists, check the shielded cable. Only the shield should be connected to terminal 2 on the ESS. STOP.
The indicator lamp is turned off.Go to Step 2.
Check the protection switches.
Remove the jumper that is between terminals (TS-9) and (TS-10) of the junction box.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The problem is in the oil pressure switches or the water temperature contactor switch. Go to Step 8 of "Problem 1".
The engine starts but engine shutdown occurs immediately.Go to Step 1 of "Problem 3".
The engine starts and the engine runs but engine shutdown occurs after the engine runs for more than 3 minutes.Go to Step 3.
The engine cranks but the engine does not start.Go to Step 1 of "Problem 1".
Check the start/stop switch.
Disconnect the wire in the junction box that connects terminal (SR1-85) of the slave relay (SR1) to terminal (TD-7) of the time delay relay (TD).
Disconnect the wire from terminal (TD-7) and insulate the exposed wire.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch has a short circuit or a wiring problem is causing a voltage at terminal (TD-7). Reconnect the wire to the terminal.
Check the start/stop switch.
Disconnect the wire that runs from the STOP position of terminal (SSS-6) to terminal (TD-6). Terminal (SSS-6) is on the start/stop switch.
Disconnect the wire at terminal (TD-7).
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch is faulty. Replace the switch. STOP.
Engine shutdown still occurs.Reconnect the wire to terminal (TD-7). Go to Step 5
Check the slave relay (SR1).
Disconnect the wire that connects terminal (TS-10) of the junction box to terminal (TD-6) of the time delay relay.
Disconnect the wire at terminal (TD-6).
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch is faulty. Replace the start/stop switch. STOP.
Engine shutdown still occurs.The contacts of SR1 periodically close. The problem may also be with the governor or the fuel supply to the engine. Refer to the Engine Service Manual. If a 2301A Electric Governor is used, the SR1 contacts may be opening. Refer to 2301A Electric Governor Service Manual, SENR3585. Test SR1. Refer to Testing and Adjusting, "Slave Relay Test".Problem 6
Engine shutdown does not occur

Have questions with 105030-4640?





Group cross 105030-4640 ZEXEL

Hino 

9 430 616 102 
236202330A 
NOZZLE-HOLDER
9 430 615 210 
236202331A 
NOZZLE-HOLDER
9 430 615 288 
 
NOZZLE-HOLDER ASSEMBLY

Mitsubishi-Heav 

9 430 615 255 
35A6109300 
NOZZLE-HOLDER
9 430 615 436 
 
NOZZLE-HOLDER ASSEMBLY
105030-4640  
9 430 615 441 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 381 
 
NOZZLE-HOLDER

Isuzu 

9 430 615 382 
8-94395-9900 
8943959900 
NOZZLE-HOLDER
9 430 615 289 
 
NOZZLE-HOLDER ASSEMBLY
9 430 615 452 
 
NOZZLE-HOLDER ASSEMBLY
 
 
NOZZLE-HOLDER

Hino 

9 430 615 211 
236202430A 
NOZZLE-HOLDER
9 430 616 103 
23620-2431A 
236202431A 
NOZZLE-HOLDER
9 430 616 142 
 
NOZZLE-HOLDER ASSEMBLY
Back to top